510(k) Report

De Novo · Granted

Granted

CleanCisionTM Wound Retraction and Protection System

DEN150038De NovoGranted Dec 16, 2016491-day reviewClass II21 CFR 878.4371

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Prescient Surgical · PQI Wound Retraction And Protection System

Granted on Dec 16, 2016 as a new device type through De Novo after a 491-day review. 1 later device descends from it.

Decided
Dec 16, 2016
Review
491 days
Class
Class II
Product code
PQI
Recalls
None

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared201620182020202220242026
  1. This deviceDEN150038 CleanCisionTM Wound Retraction and Protection SystemPrescient Surgical · 2016
  2. Descendant · cites it directly · 0 of its ownK172132 CleanCision Wound Retraction and Protection SystemPrescient Surgical, Inc. · 2017

Most influential descendants

Showing 1 of 1 · See all
  • K172132CleanCision Wound Retraction and Protection SystemPrescient Surgical, Inc. · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)DEN150038CleanCisionTM Wound Retraction and Protection SystemPrescient Surgical2016—
+1K172132CleanCision Wound Retraction and Protection SystemPrescient Surgical, Inc.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
FIG. 1 — Lineage of DEN150038, 2016–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA De Novo database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PQI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

Does it have a predicate?

De Novo decisions do not claim a predicate device.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172132CleanCision Wound Retraction and Protection SystemPrescient Surgical, Inc.20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K172132 (Prescient Surgical, Inc., 2017) has gone furthest, with 0 descendants of its own.

How does its category compare?

All PQI devices

PQI Wound Retraction And Protection System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · PQI

1in 2017

2016: 12017: 1
2007high 1 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PQI

Too few PQI 510(k)s in any year since 2007 to give a median.

Recalls per year · PQI

No recall names PQI since 2007.

Adverse event reports per year · PQI

No MAUDE report names PQI since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—00
20171—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

Indicated for use by a surgeon during abdominal surgery to retract the surgical incision, provide access to the abdominal cavity, and irrigate the surgical wound edge. The device may aid in the prevention of wound edge contamination. This device is intended to deliver a sterile irrigant solution and serve as a conduit for fluid removal from the surgical wound edge.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “DEN150038: CleanCisionTM Wound Retraction and Protection System.” Lineage record from FDA De Novo data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/DEN150038

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026