Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Flashback Technologies, Inc. · PPW Adjunctive Cardiovascular Status Indicator

Granted on Dec 21, 2016 as a new device type through De Novo after a 211-day review. 15 later devices descend from it.

Decided
Dec 21, 2016
Review
211 days
Class
Class II
Product code
PPW
Recalls
None

15 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2022: 2 descendants cleared2018: 1 descendant cleared2025: 5 descendants cleared2023: 4 descendants cleared2024: 2 descendants cleared2026: 1 descendant cleared201620182020202220242026
  1. This deviceDEN160020 CipherOx CRI TabletFlashback Technologies, Inc. · 2016
  2. Descendant · cites it directly · 12 of its ownK213230 T3 Platform SoftwareEtiometry, Inc. · 2022
  3. Descendant · 2 generations on · 7 of its ownK222463 EchoGo Heart FailureUltromics Limited · 2022
  4. Descendant · 3 generations on · 2 of its ownK240860 EchoGo Amyloidosis (1.0)Ultromics Limited · 2024
  5. Descendant · 2 generations on · 2 of its ownK223578 T3 Platform softwareEtiometry, Inc. · 2023
  6. Descendant · 2 generations on · 2 of its ownK213423 T3 Platform softwareEtiometry, Inc. · 2023

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2018: 12022: 22023: 42024: 22025: 52026: 1
2018high 5 (2025) · low 0 (2019)2026

Most influential descendants

Showing 5 of 15 · See all
  • K213230T3 Platform SoftwareEtiometry, Inc. · 2022 · cites it directly12descendants
  • K222463EchoGo Heart FailureUltromics Limited · 2022 · 2 generations on7descendants
  • K240860EchoGo Amyloidosis (1.0)Ultromics Limited · 2024 · 3 generations on2descendants
  • K223578T3 Platform softwareEtiometry, Inc. · 2023 · 2 generations on2descendants
  • K213423T3 Platform softwareEtiometry, Inc. · 2023 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)DEN160020CipherOx CRI TabletFlashback Technologies, Inc.2016—
+1K213230T3 Platform SoftwareEtiometry, Inc.2022—
+2K222463EchoGo Heart FailureUltromics Limited2022—
+3K240860EchoGo Amyloidosis (1.0)Ultromics Limited2024—
+2K223578T3 Platform softwareEtiometry, Inc.2023—
+2K213423T3 Platform softwareEtiometry, Inc.2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202220
202340
202420
202550
202610
FIG. 1 — Lineage of DEN160020, 2016–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA De Novo database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PPW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PPW device

  1. #1 K213230 T3 Platform Softwarescore 15.9 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

Does it have a predicate?

De Novo decisions do not claim a predicate device.

What descends from it? (15)

See all 15

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213230T3 Platform SoftwareEtiometry, Inc.202212
K173929CipherOx CRI M1Flashback Technologies, Inc.20181

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K213230 (Etiometry, Inc., 2022) has gone furthest, with 12 descendants of its own.

How does its category compare?

All PPW devices

PPW Adjunctive Cardiovascular Status Indicator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · PPW

2in 2025

2016: 12018: 12022: 22023: 12025: 22026 (partial year): 1
2007high 2 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PPW

Too few PPW 510(k)s in any year since 2007 to give a median.

Recalls per year · PPW

No recall names PPW since 2007.

Adverse event reports per year · PPW

No MAUDE report names PPW since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—00
20170—00
20181—00
20190—00
20200—00
20210—00
20222—00
20231—00
20240—00
20252—00
20261—0—

What is it indicated for?

The CipherOx CRI Tablet is indicated for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate (measured by an SpO2 sensor), and the Compensatory Reserve Index (CRI), which trends changes in intravascular volume relative to the individual patient’s response to hypovolemia. For patients with a finger thickness of 0.3” to 1” in hospital and pre-hospital settings. CRI trends with changes in intravascular…

Read the full statement (124 words)

The CipherOx CRI Tablet is indicated for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate (measured by an SpO2 sensor), and the Compensatory Reserve Index (CRI), which trends changes in intravascular volume relative to the individual patient’s response to hypovolemia.

For patients with a finger thickness of 0.3” to 1” in hospital and pre-hospital settings.

CRI trends with changes in intravascular volume relative to the individual patient’s response to hypovolemia, and should only be used by qualified medical providers as an adjunct to rather than as a replacement for traditional hemodynamic measures. CRI is indicated for adults (19-36 years old) in the supine position under non-motion conditions and without cardiovascular disease. CRI has not been studied in trauma patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “DEN160020: CipherOx CRI Tablet.” Lineage record from FDA De Novo data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/DEN160020

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026