510(k) Report

De Novo · Granted

Granted

Adaptive Biotechnologies clonoSEQ Assay

DEN170080De NovoGranted Sep 28, 2018364-day reviewClass II21 CFR 866.6100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Adaptive Biotechnologies Corporation · QDC Dna-Based Test For Minimal Residual Disease For Hematologic Malignancies

Granted on Sep 28, 2018 as a new device type through De Novo after a 364-day review. 1 later device descends from it.

Decided
Sep 28, 2018
Review
364 days
Class
Class II
Product code
QDC
Recalls
None

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2020: 1 descendant cleared201620182020202220242026
  1. This deviceDEN170080 Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation · 2018
  2. Descendant · cites it directly · 0 of its ownK200009 Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation · 2020

Most influential descendants

Showing 1 of 1 · See all
  • K200009Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)DEN170080Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation2018—
+1K200009Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation2020—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
FIG. 1 — Lineage of DEN170080, 2018–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA De Novo database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QDC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QDC device

  1. #1 K200009 Adaptive Biotechnologies clonoSEQ Assayscore -0.2 · 1 generation · no Class I recall
Get a 510(k) Report

Does it have a predicate?

De Novo decisions do not claim a predicate device.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200009Adaptive Biotechnologies clonoSEQ AssayAdaptive Biotechnologies Corporation20200

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K200009 (Adaptive Biotechnologies Corporation, 2020) has gone furthest, with 0 descendants of its own.

How does its category compare?

All QDC devices

QDC Dna-Based Test For Minimal Residual Disease For Hematologic Malignancies: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · QDC

1in 2020

2018: 12020: 1
2007high 1 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QDC

Too few QDC 510(k)s in any year since 2007 to give a median.

Recalls per year · QDC

No recall names QDC since 2007.

Adverse event reports per year · QDC

No MAUDE report names QDC since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20181—00
20190—00
20201—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The clonoSEQ Assay is an in vitro diagnostic that uses multiplex polymerase chain reaction (PCR) and next-generation sequencing (NGS) to identify and quantify rearranged IgH (VDJ), IgH (DJ), IgK, and IgL receptor gene sequences, as well as translocated BCL1/IgH (J) and BCL2/IgH (J) sequences in DNA extracted from bone marrow from patients with B-Cell acute lymphoblastic leukemia (ALL) or multiple myeloma (MM). The clonoSEQ Assay measures minimal residual…

Read the full statement (118 words)

The clonoSEQ Assay is an in vitro diagnostic that uses multiplex polymerase chain reaction (PCR) and next-generation sequencing (NGS) to identify and quantify rearranged IgH (VDJ), IgH (DJ), IgK, and IgL receptor gene sequences, as well as translocated BCL1/IgH (J) and BCL2/IgH (J) sequences in DNA extracted from bone marrow from patients with B-Cell acute lymphoblastic leukemia (ALL) or multiple myeloma (MM).

The clonoSEQ Assay measures minimal residual disease (MRD) to monitor changes in burden of disease during and after treatment. The test is indicated for use by qualified healthcare professionals in accordance with professional guidelines for clinical decision-making and in conjunction with other clinicopathological features.

The clonoSEQ Assay is a single-site assay performed at Adaptive Biotechnologies Corporation.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “DEN170080: Adaptive Biotechnologies clonoSEQ Assay.” Lineage record from FDA De Novo data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/DEN170080

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026