510(k) Report

De Novo · Granted

Granted

KMT2A Breakapart FISH Probe Kit PDx (CDA-LPH013)

DEN240067De NovoGranted Sep 19, 2025301-day reviewClass II21 CFR 864.1885

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cytocell Limited · SFS Revumenib Eligibility Detection System

Granted on Sep 19, 2025 as a new device type through De Novo after a 301-day review.

Decided
Sep 19, 2025
Review
301 days
Class
Class II
Product code
SFS
Recalls
None

De Novo grants create a new device type without a predicate, so this family tree starts here.

FIG. 1 — Lineage of DEN240067Source: FDA De Novo database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA De Novo database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in SFS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

Does it have a predicate?

De Novo decisions do not claim a predicate device.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All SFS devices

SFS Revumenib Eligibility Detection System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · SFS

1in 2025

2025: 1
2007high 1 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · SFS

Too few SFS 510(k)s in any year since 2007 to give a median.

Recalls per year · SFS

No recall names SFS since 2007.

Adverse event reports per year · SFS

No MAUDE report names SFS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20251—00
20260—0—

What is it indicated for?

The CDA-LPH013 KMT2A Breakapart FISH Probe Kit PDx is a fluorescence in situ hybridization (FISH) test used to detect rearrangement of the KMT2A region on chromosome 11 at location 11q23.3 in 3:1 methanol/glacial acetic acid fixed bone marrow specimens from patients with acute leukemia with KMT2A rearrangement.

The assay is indicated for detecting the presence of rearrangements involving the KMT2A region as a companion diagnostic to aid in identifying those patients for whom treatment with REVUFORJ® (revumenib) is indicated in accordance with the approved therapeutic product labeling. The CDA-LPH013 KMT2A Breakapart FISH Probe Kit PDx is not intended for monitoring of residual disease.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “DEN240067: KMT2A Breakapart FISH Probe Kit PDx (CDA-LPH013).” Lineage record from FDA De Novo data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/DEN240067

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026