510(k) Report

De Novo · Granted

Granted

SportSuite Vision Software

DEN250040De NovoGranted Jul 17, 2026318-day reviewClass II21 CFR 888.1150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stryker Endoscopy · SIT Arthroscopic Or Orthopedic Endoscopic Intraoperative Augmented Reality Video See-Through Display System

Granted on Jul 17, 2026 as a new device type through De Novo after a 318-day review.

Decided
Jul 17, 2026
Review
318 days
Class
Class II
Product code
SIT
Recalls
None

De Novo grants create a new device type without a predicate, so this family tree starts here.

FIG. 1 — Lineage of DEN250040Source: FDA De Novo database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA De Novo database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in SIT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

Does it have a predicate?

De Novo decisions do not claim a predicate device.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All SIT devices

SIT Arthroscopic Or Orthopedic Endoscopic Intraoperative Augmented Reality Video See-Through Display System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · SIT

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · SIT

Too few SIT 510(k)s in any year since 2007 to give a median.

Recalls per year · SIT

No recall names SIT since 2007.

Adverse event reports per year · SIT

No MAUDE report names SIT since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

SportSuite Vision Software is indicated for the intraoperative display of arthroscopic video and medical imaging during femoroacetabular impingement and labral repair hip arthroscopy procedures, and the display of the same information as presented by the HipCheck software and HipMap FAI Analysis. When using the device, surgical tasks are performed through a video see-through augmented reality head mounted display.

Virtual images from video see-through augmented reality shall be used by the surgeon in conjunction with the use of traditional monitors by other Operating Room staff.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “DEN250040: SportSuite Vision Software.” Lineage record from FDA De Novo data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/DEN250040

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)