510(k) · Cleared
Recalled · 2009Speedlink Transverse Connector
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Spinal Concepts, Inc. · KWP Appliance, Fixation, Spinal Interlaminal
Cleared on Oct 6, 2000 after an 88-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled 8 times.
- Decided
- Oct 6, 2000
- Review
- 88 days
- Class
- Class II
- Product code
- KWP
- Recalls
- 8
- Predicates
- 0
FDA has not posted a summary or statement for it, so its predicates are not known.
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 21, 2009 | Not classified | Z-0525-2010 | Nonconforming Material/Component | The titanium stock used to manufacturer the product is reported to exhibit areas of alloy segregation, which could result in a weakening of the strength of the metal. |
| Jan 1, 2009 | Not classified | Z-0028-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0030-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0032-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0033-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0026-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0027-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
| Jan 1, 2009 | Not classified | Z-0029-2011 | Other | The firm received complaints that the device was damaged or fractured while the surgeon was bending it prior to implantation. There were also complaints that the cam may dislodge during tightening. The firm added additional instructions… |
The 5 latest of 8 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KWP devicesKWP Appliance, Fixation, Spinal Interlaminal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWP
9in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · KWP
113in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWP
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWP
494in 2025
MAUDE reports naming product code KWP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 96 | 2 | 210 |
| 2008 | 13 | 50 | 1 | 594 |
| 2009 | 12 | 89 | 23 | 682 |
| 2010 | 14 | 186 | 2 | 474 |
| 2011 | 12 | 67 | 6 | 792 |
| 2012 | 18 | 112 | 1 | 918 |
| 2013 | 12 | 99 | 3 | 1,090 |
| 2014 | 13 | 138 | 0 | 1,022 |
| 2015 | 9 | 113 | 1 | 1,348 |
| 2016 | 0 | — | 3 | 1,379 |
| 2017 | 0 | — | 0 | 864 |
| 2018 | 0 | — | 1 | 657 |
| 2019 | 0 | — | 2 | 518 |
| 2020 | 0 | — | 0 | 796 |
| 2021 | 0 | — | 0 | 525 |
| 2022 | 0 | — | 2 | 335 |
| 2023 | 0 | — | 0 | 332 |
| 2024 | 0 | — | 0 | 436 |
| 2025 | 0 | — | 0 | 494 |
| 2026 | 0 | — | 0 | — |