510(k) · Cleared
ClearedIti Dental Implant System Monotype Implant
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Straumann USA · DZE Implant, Endosseous, Root-Form
Cleared on Nov 1, 2000 after an 89-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 553 later devices descend from it.
- Decided
- Nov 1, 2000
- Review
- 89 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 0
553 later devices descend from it, 4 citing it directly.
- This deviceK002374 Iti Dental Implant System Monotype ImplantStraumann USA · 2000
- Descendant · cites it directly · 305 of its ownK013227 Screw Vent Implant; Tapered Screw Vent ImplantSulzer Dental, Inc. · 2001 · Recalled
- Descendant · cites it directly · 223 of its ownK011879 3A Dental Implant SystemOsseco Biosource, Ltd. · 2002
- Descendant · 2 generations on · 222 of its ownK051576 Avana Dental Implant SystemOsstem Co., Ltd. · 2005
- Descendant · 3 generations on · 211 of its ownK062051 SS SystemOsstem Implant Co., Ltd. · 2006
- Descendant · 4 generations on · 202 of its ownK063861 GS SystemOsstem Implant Co., Ltd. · 2007
Showing 5 of 553 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 553 · See all- K013227Screw Vent Implant; Tapered Screw Vent ImplantSulzer Dental, Inc. · 2001 · cites it directly305descendants
- K0118793A Dental Implant SystemOsseco Biosource, Ltd. · 2002 · cites it directly223descendants
- K051576Avana Dental Implant SystemOsstem Co., Ltd. · 2005 · 2 generations on222descendants
- K062051SS SystemOsstem Implant Co., Ltd. · 2006 · 3 generations on211descendants
- K063861GS SystemOsstem Implant Co., Ltd. · 2007 · 4 generations on202descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K002374 | Iti Dental Implant System Monotype Implant | Straumann USA | 2000 | — |
| +1 | K013227 | Screw Vent Implant; Tapered Screw Vent Implant | Sulzer Dental, Inc. | 2001 | 2 |
| +1 | K011879 | 3A Dental Implant System | Osseco Biosource, Ltd. | 2002 | — |
| +2 | K051576 | Avana Dental Implant System | Osstem Co., Ltd. | 2005 | — |
| +3 | K062051 | SS System | Osstem Implant Co., Ltd. | 2006 | — |
| +4 | K063861 | GS System | Osstem Implant Co., Ltd. | 2007 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
| 2002 | 2 | 0 |
| 2003 | 1 | 0 |
| 2005 | 3 | 0 |
| 2006 | 7 | 0 |
| 2007 | 10 | 0 |
| 2008 | 18 | 0 |
| 2009 | 12 | 0 |
| 2010 | 11 | 0 |
| 2011 | 16 | 0 |
| 2012 | 19 | 0 |
| 2013 | 32 | 0 |
| 2014 | 25 | 0 |
| 2015 | 22 | 0 |
| 2016 | 26 | 0 |
| 2017 | 24 | 0 |
| 2018 | 25 | 0 |
| 2019 | 22 | 0 |
| 2020 | 42 | 0 |
| 2021 | 32 | 0 |
| 2022 | 40 | 0 |
| 2023 | 54 | 0 |
| 2024 | 48 | 0 |
| 2025 | 38 | 0 |
| 2026 | 23 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (553)
See all 5534 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K013227 (Sulzer Dental, Inc., 2001) has gone furthest, with 305 descendants of its own.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
https://510kreport.com/device/K002374 · printed Nov 5, 2026
Cite this page
510(k) Report. “K002374: Iti Dental Implant System Monotype Implant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K002374
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026