Stryker Corp. · LOD Bone Cement
Cleared on Jan 26, 2001 after a 154-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 216 later devices descend from it. It has been recalled once.
- Decided
- Jan 26, 2001
- Review
- 154 days
- Class
- Class II
- Product code
- LOD
- Recalls
- 1
- Predicates
- 0
216 later devices descend from it, 4 citing it directly.
- This deviceK002652 Surgical Simplex P Radiopaque Bone Cement and Acm and MixevaciiStryker Corp. · 2001
- Descendant · cites it directly · 212 of its ownK033801 Kyphx HV-R, Model C01AKyphon, Inc. · 2004 · Recalled
- Descendant · cites it directly · 209 of its ownK041584 Kyphx HV-R Bone Cement, Model C01AKyphon, Inc. · 2004 · Recalled
- Descendant · 2 generations on · 189 of its ownK042691 Vertefix Vertebroplasty Procedure SetCook, Inc. · 2005
- Descendant · 2 generations on · 176 of its ownK060300 Confidence High Viscosity Bone CementDisc-O-Tech Medical Technologies, Ltd. · 2006 · Recalled
- Descendant · 2 generations on · 167 of its ownK093828 Kyph X HV-R Bone CementMedtronic, Inc. · 2010
Showing 5 of 216 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 216 · See all- K033801Kyphx HV-R, Model C01AKyphon, Inc. · 2004 · cites it directly212descendants
- K041584Kyphx HV-R Bone Cement, Model C01AKyphon, Inc. · 2004 · cites it directly209descendants
- K042691Vertefix Vertebroplasty Procedure SetCook, Inc. · 2005 · 2 generations on189descendants
- K060300Confidence High Viscosity Bone CementDisc-O-Tech Medical Technologies, Ltd. · 2006 · 2 generations on176descendants
- K093828Kyph X HV-R Bone CementMedtronic, Inc. · 2010 · 2 generations on167descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K002652 | Surgical Simplex P Radiopaque Bone Cement and Acm and Mixevacii | Stryker Corp. | 2001 | — |
| +1 | K033801 | Kyphx HV-R, Model C01A | Kyphon, Inc. | 2004 | 2 |
| +1 | K041584 | Kyphx HV-R Bone Cement, Model C01A | Kyphon, Inc. | 2004 | 2 |
| +2 | K042691 | Vertefix Vertebroplasty Procedure Set | Cook, Inc. | 2005 | — |
| +2 | K060300 | Confidence High Viscosity Bone Cement | Disc-O-Tech Medical Technologies, Ltd. | 2006 | 8 |
| +2 | K093828 | Kyph X HV-R Bone Cement | Medtronic, Inc. | 2010 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 4 | 0 |
| 2006 | 8 | 0 |
| 2007 | 10 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 5 | 0 |
| 2012 | 1 | 0 |
| 2013 | 2 | 0 |
| 2014 | 2 | 0 |
| 2015 | 2 | 0 |
| 2016 | 3 | 0 |
| 2017 | 7 | 0 |
| 2018 | 9 | 0 |
| 2019 | 8 | 0 |
| 2020 | 16 | 0 |
| 2021 | 15 | 0 |
| 2022 | 16 | 0 |
| 2023 | 26 | 0 |
| 2024 | 24 | 0 |
| 2025 | 21 | 0 |
| 2026 | 28 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LOD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LOD device
- #1 K254107 Refobacin Bone Cement R (110034355)score 11.8 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (216)
See all 2164 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 7, 2022 | Class III | Z-0736-2023 | Under Investigation by firm | Instructions for Use (IFU) included in the packaging is missing a translation in the Turkish language. Although the Turkish translation is missing, all content within the IFUs is accurate. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K033801 (Kyphon, Inc., 2004) has gone furthest, with 212 descendants of its own.
How does its category compare?
All LOD devicesLOD Bone Cement: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LOD
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LOD
277in 2022
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LOD
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LOD
355in 2025
MAUDE reports naming product code LOD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 78 |
| 2008 | 1 | — | 0 | 134 |
| 2009 | 3 | 103 | 0 | 170 |
| 2010 | 0 | — | 0 | 291 |
| 2011 | 0 | — | 0 | 428 |
| 2012 | 0 | — | 0 | 412 |
| 2013 | 2 | — | 0 | 501 |
| 2014 | 1 | — | 1 | 465 |
| 2015 | 4 | 138 | 0 | 529 |
| 2016 | 1 | — | 0 | 615 |
| 2017 | 3 | 96 | 4 | 817 |
| 2018 | 2 | — | 0 | 1,295 |
| 2019 | 4 | 90 | 0 | 2,307 |
| 2020 | 3 | 139 | 1 | 1,294 |
| 2021 | 4 | 95 | 0 | 782 |
| 2022 | 3 | 277 | 2 | 472 |
| 2023 | 2 | — | 0 | 475 |
| 2024 | 1 | — | 0 | 492 |
| 2025 | 1 | — | 0 | 355 |
| 2026 | 1 | — | 2 | — |
https://510kreport.com/device/K002652 · printed Nov 6, 2026
Cite this page
510(k) Report. “K002652: Surgical Simplex P Radiopaque Bone Cement and Acm and Mixevacii.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K002652
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026