510(k) Report

510(k) · Cleared

Recalled · 2004

Biomet BI-Polar Shoulder System

K002998510(k) SpecialCleared Oct 6, 200010-day reviewClass II21 CFR 888.3650Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomet, Inc. · KWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

Cleared on Oct 6, 2000 as substantially equivalent to K991585 (Biomet, Inc., 1999) after a 10-day review. Its family tree reaches back 2 generations to 1980. 1 of the 269 devices in its family, counting itself, has a Class I recall. 265 later devices descend from it. It has been recalled once.

Decided
Oct 6, 2000
Review
10 days
Class
Class II
Product code
KWT
Recalls
1
Predicates
1

Its longest line of descent runs back 2 generations to K800494 (1980). 3 ancestors in all. 265 later devices descend from it, 4 citing it directly. 1 of the 269 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1980: 1 other ancestor2006: 6 descendants cleared2003: 4 descendants cleared2001: 2 descendants cleared2013: 12 descendants cleared2012: 12 descendants cleared2005: 3 descendants cleared2008: 2 descendants cleared, 1 with a Class I recall12007: 4 descendants cleared2017: 13 descendants cleared2014: 10 descendants cleared2019: 18 descendants cleared2011: 9 descendants cleared2004: 1 descendant cleared2015: 6 descendants cleared2021: 24 descendants cleared2016: 10 descendants cleared2020: 18 descendants cleared2018: 15 descendants cleared2022: 21 descendants cleared2025: 19 descendants cleared2010: 5 descendants cleared2009: 1 descendant cleared2023: 17 descendants cleared2024: 14 descendants cleared2026: 19 descendants clearedK800494 · New Jersey Hemiarthroplasty Sholder Pros · Depuy, Inc. · 1980K991585 · Bipolar Shoulder Prosthesis · Biomet, Inc. · 199919801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 4 descendants2 generations forward: 29 descendants3 generations forward: 51 descendants, 1 with a Class I recall14 generations forward: 74 descendants5 generations forward: 50 descendants6 generations forward: 25 descendants7 generations forward: 19 descendants8 generations forward: 10 descendants9 generations forward: 3 descendants K991585 · Bipolar Shoulder Prosthesis · Biomet, Inc. · 1999K800494 · New Jersey Hemiarthroplasty Sholder Pros · Depuy, Inc. · 19800+5
  1. Root · 2 generations backK800494 New Jersey Hemiarthroplasty Sholder ProsDepuy, Inc. · 1980
  2. 1 generation backK991585 Bipolar Shoulder ProsthesisBiomet, Inc. · 1999
  3. This deviceK002998 Biomet BI-Polar Shoulder SystemBiomet, Inc. · 2000
  4. Descendant · cites it directly · 253 of its ownK030710 Bio-Modular Shoulder SystemBiomet, Inc. · 2003 · Recalled
  5. Descendant · 2 generations on · 176 of its ownK043100 Bio-Modular Shoulder System with Hydroxyapatite (HA) Coated Glenoid…Biomet, Inc. · 2005 · Recalled
  6. Descendant · 2 generations on · 175 of its ownK072804 Comprehensive RS Shoulder SystemBiomet Manufacturing Corp · 2007
  7. Descendant · 3 generations on · 172 of its ownK080642 Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · Recalled (Class I)
  8. Descendant · cites it directly · 142 of its ownK010827 Copeland MB/HA Resurfacing Humeral HeadsBiomet Orthopedics, Inc. · 2001 · Recalled

Showing 5 of 265 descendants. See all descendants

Descendants cleared per year

2001: 22003: 42004: 12005: 32006: 62007: 42008: 22009: 12010: 52011: 92012: 122013: 122014: 102015: 62016: 102017: 132018: 152019: 182020: 182021: 242022: 212023: 172024: 142025: 192026: 19
2001high 24 (2021) · low 0 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 265 · See all
  • K030710Bio-Modular Shoulder SystemBiomet, Inc. · 2003 · cites it directly253descendants
  • K043100Bio-Modular Shoulder System with Hydroxyapatite (HA) Coated Glenoid ComponentsBiomet, Inc. · 2005 · 2 generations on176descendants
  • K072804Comprehensive RS Shoulder SystemBiomet Manufacturing Corp · 2007 · 2 generations on175descendants
  • K080642Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · 3 generations on172descendants
  • K010827Copeland MB/HA Resurfacing Humeral HeadsBiomet Orthopedics, Inc. · 2001 · cites it directly142descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K800494New Jersey Hemiarthroplasty Sholder ProsDepuy, Inc.1980—
−1K991585Bipolar Shoulder ProsthesisBiomet, Inc.1999—
0 (this device)K002998Biomet BI-Polar Shoulder SystemBiomet, Inc.2000—
+1K030710Bio-Modular Shoulder SystemBiomet, Inc.20031
+2K043100Bio-Modular Shoulder System with Hydroxyapatite (HA) Coated Glenoid ComponentsBiomet, Inc.20051
+2K072804Comprehensive RS Shoulder SystemBiomet Manufacturing Corp2007—
+3K080642Comprehensive Reverse ShoulderBiomet, Inc.2008Class I
+1K010827Copeland MB/HA Resurfacing Humeral HeadsBiomet Orthopedics, Inc.20011

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200120
200340
200410
200530
200660
200740
200821
200910
201050
201190
2012120
2013120
2014100
201560
2016100
2017130
2018150
2019180
2020180
2021240
2022210
2023170
2024140
2025190
2026190
FIG. 1 — Lineage of K002998, 1980–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWT device

  1. #1 K231657 AGILON® XO Shoulder Replacement Systemscore 17.7 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K991585Bipolar Shoulder Prosthesis
Summary page 2
…on Implant loosening/migration Fractureof the components Excessivewear Tissuegrowth failure Nervedamage Predicate Device(s): BiometR Bi-Polar Shoulder,K991585 000172 e“” “m”t. 5' DEPARTMENT OF HEALTH & HUMAN SERVICES Public Healt…
Biomet, Inc.1999—

Also cleared against K991585: 6 other devices →

What descends from it? (265)

See all 265

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K030710Bio-Modular Shoulder SystemBiomet, Inc.2003253
K010827Copeland MB/HA Resurfacing Humeral HeadsBiomet Orthopedics, Inc.2001142
K010657Copeland MB Resurfacing Humeral HeadsBiomet Manufacturing, Inc.2001136
K060716Versa-Dial Humeral Head ProsthesisBiomet Manufacturing Corp200616

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 23, 2004Not classifiedZ-0777-04OtherThe locking ring was not included and the shoulder implanted without the locking ring.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K080642Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 20 years and passes through 2 companies; a new generation was cleared every 19.4 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K030710 (Biomet, Inc., 2003) has gone furthest, with 253 descendants of its own.
  • 6 other devices also cite its predicate K991585.

How does its category compare?

All KWT devices

KWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWT

4in 2025

2007: 12010: 12011: 52012: 12013: 12014: 12015: 22016: 22017: 12018: 22019: 42020: 12021: 12022: 12023: 12024: 12025: 42026 (partial year): 1
2007high 5 (2011) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWT

242in 2025

2011: 165 days median2019: 91 days median2025: 242 days median
2007high 242 (2025) · low 91 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWT

1in 2023

2008: 12010: 72012: 22013: 12016: 12017: 12018: 12019: 32023: 1
2007high 7 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWT

749in 2025

2007: 322008: 482009: 582010: 712011: 1122012: 832013: 1132014: 1682015: 1762016: 4452017: 5602018: 4802019: 4192020: 2152021: 2282022: 2732023: 3612024: 6012025: 749
2007high 749 (2025) · low 32 (2007)2025

MAUDE reports naming product code KWT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—032
20080—148
20090—058
20101—771
201151650112
20121—283
20131—1113
20141—0168
20152—0176
20162—1445
20171—1560
20182—1480
20194913419
20201—0215
20211—0228
20221—0273
20231—1361
20241—0601
202542420749
20261—0—

What is it indicated for?

The Biomet® Bi-Polar Shoulder System is indicated for use in:

1) Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis

2) Rheumatoid arthritis

3) Revision where other devices or treatments have failed

4) Correction of functional deformity

5) Treatment of acute fracture of the humeral head unmanageable using other treatment methods

6) Cuff tear arthroplasty

This is a single use implant for use with cemented or uncemented humeral components. It is intended for use with Biomet’s humeral components previously cleared by the FDA.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K002998: Biomet BI-Polar Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K002998

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026