510(k) · Cleared
ClearedStimate N601 Tens
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Everyway Medical Instruments Co.,Ltd · GZJ Stimulator, Nerve, Transcutaneous, For Pain Relief
Cleared on Jan 24, 2001 after a 72-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 2 later devices descend from it.
- Decided
- Jan 24, 2001
- Review
- 72 days
- Class
- Class II
- Product code
- GZJ
- Recalls
- None
- Predicates
- 0
2 later devices descend from it, 1 citing it directly.
- This deviceK003487 Stimate N601 TensEveryway Medical Instruments Co.,Ltd · 2001
- Descendant · cites it directly · 1 of its ownK021794 Tatung TMD-26AX Series Tens, Models NO. TMD-26AB Tatung Tens (Blue…Tatung Co. · 2003
- Descendant · 2 generations on · 0 of its ownK040311 Shian Jia Meei Digatal PWN Tens, Model YW-6000/UC-332/UC-330/ST-331Shian Jia Meei Enterprise Co., Ltd. · 2004
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K003487 | Stimate N601 Tens | Everyway Medical Instruments Co.,Ltd | 2001 | — |
| +1 | K021794 | Tatung TMD-26AX Series Tens, Models NO. TMD-26AB Tatung Tens (Blue Housing)… | Tatung Co. | 2003 | — |
| +2 | K040311 | Shian Jia Meei Digatal PWN Tens, Model YW-6000/UC-332/UC-330/ST-331 | Shian Jia Meei Enterprise Co., Ltd. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GZJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GZJ device
- #1 K252767 actiTENS miniscore 13.1 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K021794 | Tatung TMD-26AX Series Tens, Models NO. TMD-26AB Tatung Tens (Blue Housing) TMD-26AY… | 2003 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K021794 (Tatung Co., 2003) has gone furthest, with 1 descendant of its own.
How does its category compare?
All GZJ devicesGZJ Stimulator, Nerve, Transcutaneous, For Pain Relief: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GZJ
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GZJ
207in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GZJ
1in 2011
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · GZJ
13in 2025
MAUDE reports naming product code GZJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 223 | 4 | 4 |
| 2008 | 11 | 136 | 1 | 45 |
| 2009 | 16 | 155 | 0 | 17 |
| 2010 | 5 | 232 | 0 | 22 |
| 2011 | 5 | 168 | 1 | 22 |
| 2012 | 12 | 154 | 0 | 20 |
| 2013 | 2 | — | 0 | 10 |
| 2014 | 4 | 344 | 0 | 23 |
| 2015 | 3 | 202 | 0 | 18 |
| 2016 | 3 | 163 | 0 | 32 |
| 2017 | 3 | 113 | 0 | 58 |
| 2018 | 2 | — | 0 | 21 |
| 2019 | 3 | 156 | 0 | 7 |
| 2020 | 4 | 183 | 0 | 10 |
| 2021 | 3 | 231 | 0 | 5 |
| 2022 | 4 | 175 | 0 | 4 |
| 2023 | 1 | — | 0 | 39 |
| 2024 | 3 | 207 | 0 | 12 |
| 2025 | 1 | — | 0 | 13 |
| 2026 | 2 | — | 0 | — |
https://510kreport.com/device/K003487 · printed Nov 4, 2026
Cite this page
510(k) Report. “K003487: Stimate N601 Tens.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K003487
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026