510(k) Report

510(k) · Cleared

Recalled · 2006

Cannulated Screw System

K003496510(k) TraditionalCleared Feb 8, 200187-day reviewClass II21 CFR 888.3030Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pioneer Surgical Technology · HTN Washer, Bolt Nut

Cleared on Feb 8, 2001 after an 87-day review. The FDA summary names its predicate without a number. 1 of the 346 devices in its family, counting itself, has a Class I recall. 345 later devices descend from it. It has been recalled once.

Decided
Feb 8, 2001
Review
87 days
Class
Class II
Product code
HTN
Recalls
1
Predicates
0

345 later devices descend from it, 6 citing it directly. 1 of the 346 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2015: 20 descendants cleared2011: 4 descendants cleared2006: 2 descendants cleared2010: 2 descendants cleared2013: 5 descendants cleared2017: 12 descendants cleared2026: 48 descendants cleared2019: 16 descendants cleared2012: 2 descendants cleared2014: 8 descendants cleared2025: 44 descendants cleared2016: 11 descendants cleared2023: 42 descendants cleared2020: 22 descendants cleared2021: 23 descendants cleared, 1 with a Class I recall12022: 32 descendants cleared2018: 7 descendants cleared2024: 45 descendants cleared200020052010201520202025
  1. This deviceK003496 Cannulated Screw SystemPioneer Surgical Technology · 2001
  2. Descendant · cites it directly · 309 of its ownK102903 Pioneer Cannulated Screw SystemPioneer Surgical Technology, Inc. · 2010
  3. Descendant · cites it directly · 161 of its ownK111994 Smith & Nephew Cannulated Screws and WashersSmith & Nephew, Inc. · 2011
  4. Descendant · cites it directly · 135 of its ownK112885 Zimmer Plates and Screws System Screws OnlyZimmer, Inc. · 2011 · Recalled
  5. Descendant · 2 generations on · 133 of its ownK131405 Ifuse Implant SystemSI-BONE, Inc. · 2013
  6. Descendant · 2 generations on · 92 of its ownK110472 SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek · 2012

Showing 5 of 345 descendants. See all descendants

Descendants cleared per year

2006: 22010: 22011: 42012: 22013: 52014: 82015: 202016: 112017: 122018: 72019: 162020: 222021: 232022: 322023: 422024: 452025: 442026: 48
2006high 48 (2026) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 345 · See all
  • K102903Pioneer Cannulated Screw SystemPioneer Surgical Technology, Inc. · 2010 · cites it directly309descendants
  • K111994Smith & Nephew Cannulated Screws and WashersSmith & Nephew, Inc. · 2011 · cites it directly161descendants
  • K112885Zimmer Plates and Screws System Screws OnlyZimmer, Inc. · 2011 · cites it directly135descendants
  • K131405Ifuse Implant SystemSI-BONE, Inc. · 2013 · 2 generations on133descendants
  • K110472SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek · 2012 · 2 generations on92descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K003496Cannulated Screw SystemPioneer Surgical Technology2001—
+1K102903Pioneer Cannulated Screw SystemPioneer Surgical Technology, Inc.2010—
+1K111994Smith & Nephew Cannulated Screws and WashersSmith & Nephew, Inc.2011—
+1K112885Zimmer Plates and Screws System Screws OnlyZimmer, Inc.201115
+2K131405Ifuse Implant SystemSI-BONE, Inc.2013—
+2K110472SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200620
201020
201140
201220
201350
201480
2015200
2016110
2017120
201870
2019160
2020220
2021231
2022320
2023420
2024450
2025440
2026480
FIG. 1 — Lineage of K003496, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HTN device

  1. #1 K201522 Arthrex Syndesmosis TightRope XP Buttress…score 16.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Zimmer Magna-FX
Named without a submission number
—
*—ZIMMER Mini MAGNA-FX
Named without a submission number
—
*—Synthes Cannulated Screw System
Named without a submission number
—

What descends from it? (345)

See all 345

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102903Pioneer Cannulated Screw SystemPioneer Surgical Technology, Inc.2010309
K111994Smith & Nephew Cannulated Screws and WashersSmith & Nephew, Inc.2011161
K112885Zimmer Plates and Screws System Screws OnlyZimmer, Inc.2011135
K060156Straight Plate with Angular Stability & Screw SystemI.T.S. Implantat-Technologie-Systeme GmbH200627
K150693PHIN-FX Cannulated Lag Screw SystemAscent Medical, LLC20159
K111086Orthopediatrics Fracture and Osteotomy Bone Plate SystemOrthoPediatrics Corp.20117

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 3, 2006Not classifiedZ-0872-06OtherThere may be an obstruction in the cannula that will prevent the guide wire from passing through it. The obstruction in the cannula can force the guidewire to advance further into the patient than intended.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K211616ExcelsiusHubGlobus Medical, Inc. · 2021 · 4 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K102903 (Pioneer Surgical Technology, Inc., 2010) has gone furthest, with 309 descendants of its own.

How does its category compare?

All HTN devices

HTN Washer, Bolt Nut: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HTN

4in 2025

2007: 12008: 22009: 32011: 42013: 32014: 82015: 22016: 12017: 62018: 22019: 52020: 32021: 22022: 52023: 22024: 62025: 42026 (partial year): 2
2007high 8 (2014) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HTN

75in 2025

2009: 86 days median2011: 130 days median2013: 105 days median2014: 98 days median2017: 88 days median2019: 116 days median2020: 87 days median2022: 86 days median2024: 90 days median2025: 75 days median
2007high 130 (2011) · low 75 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HTN

1in 2019

2013: 12019: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HTN

190in 2025

2007: 142008: 112009: 222010: 172011: 122012: 692013: 452014: 332015: 352016: 432017: 302018: 482019: 532020: 812021: 1492022: 852023: 1082024: 2692025: 190
2007high 269 (2024) · low 11 (2008)2025

MAUDE reports naming product code HTN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—014
20082—011
2009386022
20100—017
20114130012
20120—069
20133105145
2014898033
20152—035
20161—043
2017688030
20182—048
20195116153
2020387081
20212—0149
2022586085
20232—0108
20246900269
20254750190
20262—0—

What is it indicated for?

The Cannulated Screw System by Pioneer will be indicated for use in long and small bone fracture fixation, which may include the following: 1. Fractures of the tarsals and metatarsals; 2. Metatarsal and phalangeal osteotomies; 3. Fractures of the carpals and metacarpals; 4. Carpal and metacarpal arthrodesis; 5. Small fragments of the hand and wrist; 6. Ligament fixation as appropriate; 7. Sacroiliac joint disruptions; 8. Fractures of the distal femur and…

Read the full statement (117 words)

The Cannulated Screw System by Pioneer will be indicated for use in long and small bone fracture fixation, which may include the following:

1. Fractures of the tarsals and metatarsals;

2. Metatarsal and phalangeal osteotomies;

3. Fractures of the carpals and metacarpals;

4. Carpal and metacarpal arthrodesis;

5. Small fragments of the hand and wrist;

6. Ligament fixation as appropriate;

7. Sacroiliac joint disruptions;

8. Fractures of the distal femur and proximal tibia;

9. Intracapsular fractures of the hip;

10. Ankle arthrodesis; and

11. Pelvis and acetabulum fractures;

This system is not indicated for use in the spine. The Cannulated Screw System by Pioneer will be offered both sterile and non-sterile and is a single use device.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K003496: Cannulated Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K003496

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026