510(k) · Cleared
ClearedNewtom QR-DVT 9000
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Aperio Services, LLC · OAS X-Ray, Tomography, Computed, Dental
Cleared on Mar 8, 2001 after a 90-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 104 later devices descend from it.
- Decided
- Mar 8, 2001
- Review
- 90 days
- Class
- Class II
- Product code
- OAS
- Recalls
- None
- Predicates
- 0
104 later devices descend from it, 6 citing it directly.
- This deviceK003787 Newtom QR-DVT 9000Aperio Services, LLC · 2001
- Descendant · cites it directly · 88 of its ownK030450 3D Accu-I-Tomo Xyz Slice View TomographJ. Morita USA, Inc. · 2003
- Descendant · 2 generations on · 66 of its ownK052587 3D Accu-I-Tomo Xyz Slice View Tomograph, Model MCT-1 ExfJ. Morita USA, Inc. · 2005
- Descendant · 3 generations on · 61 of its ownK060328 Planmeca Promax 3DPlanmeca Oy · 2006
- Descendant · cites it directly · 31 of its ownK061284 I-Cat ScannerImaging Sciences Intl., Inc. · 2006 · Recalled
- Descendant · 4 generations on · 27 of its ownK111152 Rotograph Evo 3DVilla Sistemi Medicali S.P.A. · 2011 · Recalled
Showing 5 of 104 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 104 · See all- K0304503D Accu-I-Tomo Xyz Slice View TomographJ. Morita USA, Inc. · 2003 · cites it directly88descendants
- K0525873D Accu-I-Tomo Xyz Slice View Tomograph, Model MCT-1 ExfJ. Morita USA, Inc. · 2005 · 2 generations on66descendants
- K060328Planmeca Promax 3DPlanmeca Oy · 2006 · 3 generations on61descendants
- K061284I-Cat ScannerImaging Sciences Intl., Inc. · 2006 · cites it directly31descendants
- K111152Rotograph Evo 3DVilla Sistemi Medicali S.P.A. · 2011 · 4 generations on27descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K003787 | Newtom QR-DVT 9000 | Aperio Services, LLC | 2001 | — |
| +1 | K030450 | 3D Accu-I-Tomo Xyz Slice View Tomograph | J. Morita USA, Inc. | 2003 | — |
| +2 | K052587 | 3D Accu-I-Tomo Xyz Slice View Tomograph, Model MCT-1 Exf | J. Morita USA, Inc. | 2005 | — |
| +3 | K060328 | Planmeca Promax 3D | Planmeca Oy | 2006 | — |
| +1 | K061284 | I-Cat Scanner | Imaging Sciences Intl., Inc. | 2006 | 2 |
| +4 | K111152 | Rotograph Evo 3D | Villa Sistemi Medicali S.P.A. | 2011 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 3 | 0 |
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
| 2006 | 4 | 0 |
| 2007 | 4 | 0 |
| 2008 | 5 | 0 |
| 2010 | 3 | 0 |
| 2011 | 7 | 0 |
| 2012 | 3 | 0 |
| 2013 | 10 | 0 |
| 2014 | 3 | 0 |
| 2015 | 3 | 0 |
| 2016 | 9 | 0 |
| 2017 | 3 | 0 |
| 2018 | 11 | 0 |
| 2019 | 3 | 0 |
| 2020 | 3 | 0 |
| 2021 | 6 | 0 |
| 2022 | 3 | 0 |
| 2023 | 5 | 0 |
| 2024 | 1 | 0 |
| 2025 | 5 | 0 |
| 2026 | 7 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OAS device
- #1 K213226 RCT700score 18.0 · 13 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (104)
See all 1046 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K030450 (J. Morita USA, Inc., 2003) has gone furthest, with 88 descendants of its own.
How does its category compare?
All OAS devicesOAS X-Ray, Tomography, Computed, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · OAS
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OAS
144in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OAS
3in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OAS
1in 2025
MAUDE reports naming product code OAS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 2 | — | 0 | 1 |
| 2009 | 2 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 6 | 168 | 0 | 0 |
| 2012 | 7 | 110 | 0 | 0 |
| 2013 | 10 | 155 | 0 | 0 |
| 2014 | 5 | 170 | 0 | 0 |
| 2015 | 5 | 164 | 1 | 0 |
| 2016 | 12 | 154 | 0 | 0 |
| 2017 | 4 | 209 | 0 | 0 |
| 2018 | 11 | 57 | 0 | 0 |
| 2019 | 7 | 55 | 0 | 1 |
| 2020 | 9 | 113 | 0 | 0 |
| 2021 | 11 | 92 | 0 | 0 |
| 2022 | 6 | 105 | 0 | 1 |
| 2023 | 12 | 77 | 0 | 1 |
| 2024 | 4 | 129 | 0 | 2 |
| 2025 | 9 | 144 | 3 | 1 |
| 2026 | 9 | 77 | 0 | — |
https://510kreport.com/device/K003787 · printed Nov 4, 2026
Cite this page
510(k) Report. “K003787: Newtom QR-DVT 9000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K003787
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026