510(k) · Cleared
ClearedPalomar SLP 1000
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Palomar Medical Technologies, Inc. · GEX Powered Laser Surgical Instrument
Cleared on May 22, 2001 after an 84-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 175 later devices descend from it.
- Decided
- May 22, 2001
- Review
- 84 days
- Class
- Class II
- Product code
- GEX
- Recalls
- None
- Predicates
- 0
175 later devices descend from it, 4 citing it directly.
- This deviceK010580 Palomar SLP 1000Palomar Medical Technologies, Inc. · 2001
- Descendant · cites it directly · 174 of its ownK011747 Palomar LC 100 Diode LaserPalomar Medical Technologies, Inc. · 2001
- Descendant · cites it directly · 173 of its ownK032846 Spectra Pulsed Diode Laser, Model DR-1Spectragenics, Inc. · 2003
- Descendant · cites it directly · 172 of its ownK052848 Spectra Hair Removal LaserSpectragenics, Inc. · 2005
- Descendant · 2 generations on · 171 of its ownK060839 Abc Hair Removal SystemPalomar Medical Technologies, Inc. · 2006
- Descendant · cites it directly · 169 of its ownK053527 Spectra Hair Removal LaserSpectragenics, Inc. · 2008
Showing 5 of 175 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 175 · See all- K011747Palomar LC 100 Diode LaserPalomar Medical Technologies, Inc. · 2001 · cites it directly174descendants
- K032846Spectra Pulsed Diode Laser, Model DR-1Spectragenics, Inc. · 2003 · cites it directly173descendants
- K052848Spectra Hair Removal LaserSpectragenics, Inc. · 2005 · cites it directly172descendants
- K060839Abc Hair Removal SystemPalomar Medical Technologies, Inc. · 2006 · 2 generations on171descendants
- K053527Spectra Hair Removal LaserSpectragenics, Inc. · 2008 · cites it directly169descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K010580 | Palomar SLP 1000 | Palomar Medical Technologies, Inc. | 2001 | — |
| +1 | K011747 | Palomar LC 100 Diode Laser | Palomar Medical Technologies, Inc. | 2001 | — |
| +1 | K032846 | Spectra Pulsed Diode Laser, Model DR-1 | Spectragenics, Inc. | 2003 | — |
| +1 | K052848 | Spectra Hair Removal Laser | Spectragenics, Inc. | 2005 | — |
| +2 | K060839 | Abc Hair Removal System | Palomar Medical Technologies, Inc. | 2006 | — |
| +1 | K053527 | Spectra Hair Removal Laser | Spectragenics, Inc. | 2008 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 1 | 0 |
| 2003 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2008 | 3 | 0 |
| 2009 | 1 | 0 |
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
| 2012 | 4 | 0 |
| 2013 | 5 | 0 |
| 2014 | 8 | 0 |
| 2015 | 4 | 0 |
| 2016 | 3 | 0 |
| 2017 | 5 | 0 |
| 2018 | 9 | 0 |
| 2019 | 6 | 0 |
| 2020 | 2 | 0 |
| 2021 | 15 | 0 |
| 2022 | 24 | 0 |
| 2023 | 30 | 0 |
| 2024 | 22 | 0 |
| 2025 | 18 | 0 |
| 2026 | 10 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEX device
- #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (175)
See all 1754 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K011747 (Palomar Medical Technologies, Inc., 2001) has gone furthest, with 174 descendants of its own.
How does its category compare?
All GEX devicesGEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEX
83in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEX
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEX
3in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GEX
2,720in 2025
MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 73 | 79 | 9 | 342 |
| 2008 | 107 | 86 | 2 | 232 |
| 2009 | 69 | 100 | 0 | 209 |
| 2010 | 50 | 96 | 4 | 1,711 |
| 2011 | 41 | 83 | 18 | 3,024 |
| 2012 | 45 | 118 | 5 | 2,000 |
| 2013 | 46 | 144 | 3 | 2,236 |
| 2014 | 61 | 147 | 6 | 2,036 |
| 2015 | 47 | 112 | 0 | 2,099 |
| 2016 | 51 | 114 | 1 | 2,585 |
| 2017 | 67 | 90 | 5 (1) | 2,977 |
| 2018 | 51 | 78 | 5 | 3,525 |
| 2019 | 41 | 88 | 6 | 2,709 |
| 2020 | 52 | 90 | 1 | 2,183 |
| 2021 | 53 | 123 | 0 | 3,465 |
| 2022 | 60 | 152 | 0 | 2,288 |
| 2023 | 52 | 87 | 6 | 2,337 |
| 2024 | 82 | 90 | 3 | 2,187 |
| 2025 | 83 | 90 | 0 | 2,720 |
| 2026 | 57 | 90 | 2 | — |
https://510kreport.com/device/K010580 · printed Nov 4, 2026
Cite this page
510(k) Report. “K010580: Palomar SLP 1000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K010580
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026