510(k) · Cleared
ClearedFox Pta Catheter, 3.0, 4.0, 5.0, 6.0, 7.0, and 8.0 X 40 MM, Models A14003, A14004, A14005, A14006, A14007, A14008
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Jomed AG · DQY Catheter, Percutaneous
Cleared on Jun 21, 2001 after a 93-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 17 later devices descend from it.
- Decided
- Jun 21, 2001
- Review
- 93 days
- Class
- Class II
- Product code
- DQY
- Recalls
- None
- Predicates
- 0
17 later devices descend from it, 2 citing it directly.
- This deviceK010838 Fox Pta Catheter, 3.0, 4.0, 5.0, 6.0, 7.0, and 8.0 X 40 MM, Models…Jomed AG · 2001
- Descendant · cites it directly · 16 of its ownK020854 Modification to Fox Pta CatheterJomed AG · 2002
- Descendant · cites it directly · 8 of its ownK033217 Pheron Pta CatheterBiotronik, Inc. · 2003
- Descendant · 2 generations on · 7 of its ownK072765 Passeo 18Biotronik, Inc. · 2007
- Descendant · 2 generations on · 5 of its ownK082933 Passeo-35 Pta CatheterBiotronik, Inc. · 2008
- Descendant · 2 generations on · 5 of its ownK040954 Fox Plus Pta CatheterAbbott Laboratories, Inc. · 2004
Showing 5 of 17 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 17 · See all- K020854Modification to Fox Pta CatheterJomed AG · 2002 · cites it directly16descendants
- K033217Pheron Pta CatheterBiotronik, Inc. · 2003 · cites it directly8descendants
- K072765Passeo 18Biotronik, Inc. · 2007 · 2 generations on7descendants
- K082933Passeo-35 Pta CatheterBiotronik, Inc. · 2008 · 2 generations on5descendants
- K040954Fox Plus Pta CatheterAbbott Laboratories, Inc. · 2004 · 2 generations on5descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K010838 | Fox Pta Catheter, 3.0, 4.0, 5.0, 6.0, 7.0, and 8.0 X 40 MM, Models A14003… | Jomed AG | 2001 | — |
| +1 | K020854 | Modification to Fox Pta Catheter | Jomed AG | 2002 | — |
| +1 | K033217 | Pheron Pta Catheter | Biotronik, Inc. | 2003 | — |
| +2 | K072765 | Passeo 18 | Biotronik, Inc. | 2007 | — |
| +2 | K082933 | Passeo-35 Pta Catheter | Biotronik, Inc. | 2008 | — |
| +2 | K040954 | Fox Plus Pta Catheter | Abbott Laboratories, Inc. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 2 | 0 |
| 2007 | 2 | 0 |
| 2008 | 3 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 2 | 0 |
| 2023 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQY device
- #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (17)
See all 172 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K020854 (Jomed AG, 2002) has gone furthest, with 16 descendants of its own.
How does its category compare?
All DQY devicesDQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DQY
21in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQY
115in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQY
1in 2025
Class I (10 since 2007) Class II/III not classified
Adverse event reports per year · DQY
3,056in 2025
MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 85 | 6 | 313 |
| 2008 | 31 | 66 | 12 | 496 |
| 2009 | 37 | 73 | 17 | 819 |
| 2010 | 22 | 74 | 32 | 1,293 |
| 2011 | 36 | 71 | 6 | 1,211 |
| 2012 | 30 | 87 | 2 | 1,191 |
| 2013 | 32 | 92 | 36 (1) | 1,352 |
| 2014 | 19 | 127 | 3 | 1,497 |
| 2015 | 27 | 118 | 3 | 2,337 |
| 2016 | 22 | 117 | 22 (7) | 2,252 |
| 2017 | 26 | 113 | 8 | 2,489 |
| 2018 | 25 | 106 | 2 | 2,855 |
| 2019 | 30 | 111 | 1 | 2,902 |
| 2020 | 20 | 120 | 2 | 2,889 |
| 2021 | 18 | 81 | 2 | 3,006 |
| 2022 | 18 | 74 | 0 | 2,643 |
| 2023 | 18 | 114 | 17 | 3,049 |
| 2024 | 16 | 87 | 1 | 3,190 |
| 2025 | 21 | 115 | 1 (1) | 3,056 |
| 2026 | 11 | 30 | 2 (1) | — |
https://510kreport.com/device/K010838 · printed Nov 4, 2026
Cite this page
510(k) Report. “K010838: Fox Pta Catheter, 3.0, 4.0, 5.0, 6.0, 7.0, and 8.0 X 40 MM, Models A14003, A14004, A14005, A14006, A14007, A14008.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K010838
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026