510(k) · Cleared
ClearedSynthes (Usa) Medium External Fixation System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Synthes (Usa) · KTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
Cleared on Jun 27, 2001 after an 83-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.
- Decided
- Jun 27, 2001
- Review
- 83 days
- Class
- Class II
- Product code
- KTT
- Recalls
- None
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK011034 Synthes (Usa) Medium External Fixation SystemSynthes (Usa) · 2001
- Descendant · cites it directly · 0 of its ownK101338 Newfix External Fixation SystemTechnologia Y Diseno Industrial, S.A DE C.V · 2011
- Descendant · cites it directly · 0 of its ownK043113 Tempfix External Fixation System, MR SafeDePuy Orthopaedics, Inc. · 2005
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K011034 | Synthes (Usa) Medium External Fixation System | Synthes (Usa) | 2001 | — |
| +1 | K101338 | Newfix External Fixation System | Technologia Y Diseno Industrial, S.A DE C.V | 2011 | — |
| +1 | K043113 | Tempfix External Fixation System, MR Safe | DePuy Orthopaedics, Inc. | 2005 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 1 | 0 |
| 2011 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KTT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KTT device
- #1 K242861 TrueLok Elevatescore 21.4 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Howmedica Hoffmann® II External Fixation System Named without a submission number |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K101338 (Technologia Y Diseno Industrial, S.A DE C.V, 2011) has gone furthest, with 0 descendants of its own.
How does its category compare?
All KTT devicesKTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KTT
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KTT
88in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KTT
2in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KTT
673in 2025
MAUDE reports naming product code KTT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 55 | 2 | 45 |
| 2008 | 11 | 73 | 1 | 66 |
| 2009 | 11 | 94 | 2 | 45 |
| 2010 | 12 | 148 | 1 | 121 |
| 2011 | 10 | 157 | 0 | 196 |
| 2012 | 9 | 140 | 4 | 527 |
| 2013 | 7 | 87 | 7 | 898 |
| 2014 | 14 | 129 | 0 | 445 |
| 2015 | 12 | 60 | 0 | 401 |
| 2016 | 10 | 142 | 0 | 400 |
| 2017 | 11 | 184 | 1 | 485 |
| 2018 | 6 | 149 | 14 | 597 |
| 2019 | 8 | 110 | 3 | 800 |
| 2020 | 9 | 200 | 0 | 942 |
| 2021 | 10 | 83 | 2 | 961 |
| 2022 | 3 | 25 | 0 | 627 |
| 2023 | 7 | 29 | 0 | 554 |
| 2024 | 5 | 90 | 0 | 523 |
| 2025 | 10 | 88 | 0 | 673 |
| 2026 | 5 | 68 | 11 | — |
What is it indicated for?
Synthes Medium External Fixation System is intended for the construction of an external fixator frame for the treatment of pediatric and adult fractures.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K011034 · printed Nov 5, 2026
Cite this page
510(k) Report. “K011034: Synthes (Usa) Medium External Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011034
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026