The Percuquick Set for Percutaneous Dilation Tracheostomy

K011210510(k) TraditionalCleared Aug 15, 2001118-day reviewClass II21 CFR 868.5800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rusch Intl. · JOH Tube Tracheostomy And Tube Cuff

Cleared on Aug 15, 2001 after a 118-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 2 of the 14 devices in its family, counting itself, have a Class I recall. 13 later devices descend from it.

Decided
Aug 15, 2001
Review
118 days
Class
Class II
Product code
JOH
Recalls
None
Predicates
0

13 later devices descend from it, 3 citing it directly. 2 of the 14 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2003: 2 descendants cleared2004: 3 descendants cleared2005: 1 descendant cleared2014: 1 descendant cleared2018: 2 descendants cleared, 1 with a Class I recall12009: 1 descendant cleared2007: 1 descendant cleared2019: 1 descendant cleared, 1 with a Class I recall12010: 1 descendant cleared200020052010201520202025
  1. This deviceK011210 The Percuquick Set for Percutaneous Dilation TracheostomyRusch Intl. · 2001
  2. Descendant · cites it directly · 10 of its ownK022212 Portex Percutaneous Dilatational Tracheostomy KitsMentor Medical Limited · 2003
  3. Descendant · 2 generations on · 6 of its ownK040014 Percutaneous Dilation Tracheostomy Kit with Single Stage Dilator and…Portex, Ltd. · 2004
  4. Descendant · cites it directly · 5 of its ownK041348 Portex Ultraperc Percutaneous Dilation Tracheostomy Kit_with Serial…Smiths Medical · 2004 · Recalled
  5. Descendant · 2 generations on · 2 of its ownK133597 Ciaglia Percutaneous Tracheostomy Introducer Set/Tray, Ciaglia Blue…Cook, Inc. · 2014 · Recalled
  6. Descendant · 2 generations on · 2 of its ownK041044 Ciaglia Cheetah Percutaneous Tracheostomy Introducer SetCook, Inc. · 2004

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2003: 22004: 32005: 12007: 12009: 12010: 12014: 12018: 22019: 1
2003high 3 (2004) · low 0 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 13 · See all
  • K022212Portex Percutaneous Dilatational Tracheostomy KitsMentor Medical Limited · 2003 · cites it directly10descendants
  • K040014Percutaneous Dilation Tracheostomy Kit with Single Stage Dilator and Soft Introducers…Portex, Ltd. · 2004 · 2 generations on6descendants
  • K041348Portex Ultraperc Percutaneous Dilation Tracheostomy Kit_with Serial Dilators or Single…Smiths Medical · 2004 · cites it directly5descendants
  • K133597Ciaglia Percutaneous Tracheostomy Introducer Set/Tray, Ciaglia Blue Rhino Percutaneous…Cook, Inc. · 2014 · 2 generations on2descendants
  • K041044Ciaglia Cheetah Percutaneous Tracheostomy Introducer SetCook, Inc. · 2004 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K011210The Percuquick Set for Percutaneous Dilation TracheostomyRusch Intl.2001—
+1K022212Portex Percutaneous Dilatational Tracheostomy KitsMentor Medical Limited2003—
+2K040014Percutaneous Dilation Tracheostomy Kit with Single Stage Dilator and Soft…Portex, Ltd.2004—
+1K041348Portex Ultraperc Percutaneous Dilation Tracheostomy Kit_with Serial Dilators…Smiths Medical20041
+2K133597Ciaglia Percutaneous Tracheostomy Introducer Set/Tray, Ciaglia Blue Rhino…Cook, Inc.20141
+2K041044Ciaglia Cheetah Percutaneous Tracheostomy Introducer SetCook, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200320
200430
200510
200710
200910
201010
201410
201821
201911
FIG. 1 — Lineage of K011210, 2001–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JOH device

  1. #1 K251313 Shiley™ Adult Flexible Tracheostomy Tube XLT…score 11.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (13)

See all 13

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K022212Portex Percutaneous Dilatational Tracheostomy KitsMentor Medical Limited200310
K041348Portex Ultraperc Percutaneous Dilation Tracheostomy Kit_with Serial Dilators or Single…Smiths Medical20045
K031057Per-Fit Percutaneous Dilational Tracheostomy KitPortex, Inc.20031

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K173912BLUperc Percutaneous Dilation Tracheostomy Kit with BLUselect tube, BLUperc Percutaneous Dilation…Smiths Medical Asd, Inc. · 2018 · 2 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall
  • K193133Blue Rhino G1-Multi Percutaneous Tracheostomy Introducer Set, Blue Rhino G1-Multi Percutaneous Tracheostomy…Cook Incorporated · 2019 · 3 generations on · ◆ in the 2019 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Of its descendants, K022212 (Mentor Medical Limited, 2003) has gone furthest, with 10 descendants of its own.

How does its category compare?

All JOH devices

JOH Tube Tracheostomy And Tube Cuff: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JOH

1in 2025

2007: 12008: 22009: 12010: 22012: 12013: 32014: 32015: 32016: 12017: 12018: 32019: 22020: 12021: 22025: 1
2007high 3 (2013) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JOH

137in 2018

2013: 407 days median2014: 218 days median2015: 179 days median2018: 137 days median
2007high 407 (2013) · low 137 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JOH

1in 2023

2007: 12009: 12010: 732011: 42016: 2, 1 Class I2020: 12023: 12026 (partial year): 1
2007high 73 (2010) · low 0 (2008)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · JOH

986in 2025

2007: 1672008: 1022009: 1952010: 1,2702011: 5872012: 5002013: 5442014: 5062015: 5082016: 5722017: 4412018: 8122019: 1,0192020: 7912021: 1,0412022: 1,6322023: 1,2332024: 1,1032025: 986
2007high 1,632 (2022) · low 102 (2008)2025

MAUDE reports naming product code JOH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—1167
20082—0102
20091—1195
20102—731,270
20110—4587
20121—0500
201334070544
201432180506
201531790508
20161—2 (1)572
20171—0441
201831370812
20192—01,019
20201—1791
20212—01,041
20220—01,632
20230—11,233
20240—01,103
20251—0986
20260—1—
Cite this page

510(k) Report. “K011210: The Percuquick Set for Percutaneous Dilation Tracheostomy.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K011210

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026