510(k) Report

510(k) · Cleared

Cleared

Modification to the Bioplate Bioclip Craniotomy Fixation System

K011380510(k) SpecialCleared May 14, 20017-day reviewClass II21 CFR 872.4760

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bioplate, Inc. · JEY Plate, Bone

Cleared on May 14, 2001 after a 7-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 2 later devices descend from it.

Decided
May 14, 2001
Review
7 days
Class
Class II
Product code
JEY
Recalls
None
Predicates
0

2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2001: 1 descendant cleared200020052010201520202025
  1. This deviceK011380 Modification to the Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc. · 2001
  2. Descendant · cites it directly · 1 of its ownK013055 The Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc. · 2001
  3. Descendant · cites it directly · 0 of its ownK051293 Cranion Cranial Fixation System; Fixlock; Cranial Solutions; Ceremed…Ceremed, Inc. · 2005

Most influential descendants

Showing 2 of 2 · See all
  • K013055The Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc. · 2001 · cites it directly1descendant
  • K051293Cranion Cranial Fixation System; Fixlock; Cranial Solutions; Ceremed Fixation SystemCeremed, Inc. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K011380Modification to the Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc.2001—
+1K013055The Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc.2001—
+1K051293Cranion Cranial Fixation System; Fixlock; Cranial Solutions; Ceremed Fixation…Ceremed, Inc.2005—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200110
200510
FIG. 1 — Lineage of K011380, 2001–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JEY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JEY device

  1. #1 K252246 Leforte MMF Systemscore 15.6 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K013055The Bioplate Bioclip Craniotomy Fixation SystemBioplate, Inc.20011
K051293Cranion Cranial Fixation System; Fixlock; Cranial Solutions; Ceremed Fixation SystemCeremed, Inc.20050

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K013055 (Bioplate, Inc., 2001) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JEY devices

JEY Plate, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JEY

2in 2025

2007: 92008: 72009: 42010: 62011: 52012: 102013: 82014: 62015: 72016: 12017: 52018: 72019: 62020: 62021: 42022: 52023: 22024: 52025: 22026 (partial year): 3
2007high 10 (2012) · low 1 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JEY

159in 2024

2007: 115 days median2008: 84 days median2009: 121 days median2010: 199 days median2011: 75 days median2012: 194 days median2013: 126 days median2014: 223 days median2015: 160 days median2017: 190 days median2018: 255 days median2019: 163 days median2020: 198 days median2021: 299 days median2022: 135 days median2024: 159 days median2026 (partial year): 258 days median
2007high 299 (2021) · low 75 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JEY

1in 2020

2008: 32009: 62010: 852013: 12020: 1
2007high 85 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JEY

1,003in 2025

2007: 292008: 242009: 932010: 2152011: 2412012: 4282013: 7662014: 6162015: 7672016: 5582017: 5682018: 6082019: 5952020: 6802021: 4512022: 3442023: 4952024: 6962025: 1,003
2007high 1,003 (2025) · low 24 (2008)2025

MAUDE reports naming product code JEY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079115029
2008784324
20094121693
2010619985215
20115750241
2012101940428
201381261766
201462230616
201571600767
20161—0558
201751900568
201872550608
201961630595
202061981680
202142990451
202251350344
20232—0495
202451590696
20252—01,003
202632580—
Cite this page

510(k) Report. “K011380: Modification to the Bioplate Bioclip Craniotomy Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K011380

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026