510(k) Report

510(k) · Cleared

Cleared

Bilitec 2000, Polygram '98 PH Testing Application (Incl.Bile), Optical Fiber Prober

K011471510(k) TraditionalCleared Nov 8, 2002543-day reviewClass II21 CFR 876.1725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medtronic Functional Diagnostics A/S · FFX System, Gastrointestinal Motility (Electrical)

Cleared on Nov 8, 2002 as substantially equivalent to K981733 (Medtronic Functional Diagnostics A/S, 1999) after a 543-day review. Its family tree reaches back 2 generations to 1991.

Decided
Nov 8, 2002
Review
543 days
Class
Class II
Product code
FFX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K913387 (1991). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestor1995: 1 other ancestorK913387 · Digitrapper Mark Iii · Synectics-Dantec · 1991K981733 · Digitrapper Delta, Model 9043G0201 and Polygram '98 PH Extension Model 9043S0111 · Medtronic Functional Diagnostics A/S · 1999 · recalled19901992199419961998200020022004
  1. Root · 2 generations backK913387 Digitrapper Mark IiiSynectics-Dantec · 1991
  2. 1 generation backK981733 Digitrapper Delta, Model 9043G0201 and Polygram '98 PH Extension…Medtronic Functional Diagnostics A/S · 1999 · Recalled
  3. This deviceK011471 Bilitec 2000, Polygram '98 PH Testing Application (Incl.Bile)…Medtronic Functional Diagnostics A/S · 2002
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K913387Digitrapper Mark IiiSynectics-Dantec1991—
−1K981733Digitrapper Delta, Model 9043G0201 and Polygram '98 PH Extension Model 9043S0111Medtronic Functional Diagnostics A/S19991
0 (this device)K011471Bilitec 2000, Polygram '98 PH Testing Application (Incl.Bile), Optical Fiber…Medtronic Functional Diagnostics A/S2002—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199710
FIG. 1 — Lineage of K011471, 1991–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FFX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FFX device

  1. #1 K262621 Rapid Barostat Bag (RBB) Pump and Catheter…score 12.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K981733Digitrapper Delta, Model 9043G0201 and Polygram '98 PH Extension Model 9043S0111
Summary page 1
…functionality and intended use of the Polygram 98 pH Testing System (incl. bile) is equivalent to Medtronic Functional Diagnostics A/S’s Polygram 98 pH Testing System (K 981733). K011471 43511 Polygram 98 pH Testing System (incl. bile) 4. Device Description: The system is an ambulatory…
Medtronic Functional Diagnostics A/S19991

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 7.1 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All FFX devices

FFX System, Gastrointestinal Motility (Electrical): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FFX

1in 2025

2007: 22008: 12009: 22010: 22012: 42013: 12016: 32017: 22018: 12019: 42020: 12023: 32024: 12025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FFX

123in 2023

2012: 120 days median2016: 145 days median2019: 240 days median2023: 123 days median
2007high 240 (2019) · low 120 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FFX

2so far in 2026, the most since 2007

2009: 12011: 12026 (partial year): 2
2007high 2 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FFX

32in 2025

2009: 22010: 62011: 62012: 42013: 42014: 42015: 102016: 152017: 102018: 172019: 272020: 202021: 262022: 312023: 512024: 592025: 32
2007high 59 (2024) · low 0 (2007)2025

MAUDE reports naming product code FFX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20092—12
20102—06
20110—16
2012412004
20131—04
20140—04
20150—010
20163145015
20172—010
20181—017
20194240027
20201—020
20210—026
20220—031
20233123051
20241—059
20251—032
20261—2—

What is it indicated for?

The Polygram 98 pH Testing System is intended to record, store, view and

analyze esophageal and gastric refluxate data to diagnose reflux disorders. The

Polygram 98 pH Testing System can also be used to locate the position of the

proximal Lower Esophageal Sphincter (LES) manometrically, to assist in the

accurate placement of the pH catheter.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011471: Bilitec 2000, Polygram '98 PH Testing Application (Incl.Bile), Optical Fiber Prober.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K011471

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026