510(k) · Cleared
ClearedModel 235GE-64; Multi Purpose Flex Array Coil
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Advances, Inc. · MOS Coil, Magnetic Resonance, Specialty
Cleared on Aug 14, 2001 after an 81-day review. The FDA summary names no predicate by number.
- Decided
- Aug 14, 2001
- Review
- 81 days
- Class
- Class II
- Product code
- MOS
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MOS device
- #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MOS devicesMOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MOS
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MOS
59in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MOS
13in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MOS
2in 2025
MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 19 | 0 | 4 |
| 2008 | 19 | 33 | 2 | 2 |
| 2009 | 10 | 43 | 0 | 5 |
| 2010 | 16 | 78 | 1 | 13 |
| 2011 | 25 | 57 | 0 | 7 |
| 2012 | 15 | 49 | 1 | 12 |
| 2013 | 7 | 87 | 0 | 10 |
| 2014 | 12 | 60 | 0 | 4 |
| 2015 | 6 | 58 | 2 | 5 |
| 2016 | 11 | 42 | 0 | 7 |
| 2017 | 9 | 63 | 0 | 9 |
| 2018 | 10 | 30 | 0 | 7 |
| 2019 | 3 | 178 | 8 | 8 |
| 2020 | 5 | 51 | 1 | 2 |
| 2021 | 4 | 41 | 0 | 3 |
| 2022 | 11 | 79 | 0 | 5 |
| 2023 | 10 | 59 | 0 | 4 |
| 2024 | 10 | 39 | 13 | 8 |
| 2025 | 3 | 59 | 0 | 2 |
| 2026 | 10 | 45 | 0 | — |
What is it indicated for?
Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) of the Head: Temporal lobes (hippocampus), internal auditory canals, orbits and anterior optic pathways, cranial nerves, intracranial magnetic resonance angiography (MRA). Upper Neck: Skull base, Cranio-cervical junction, cervical carotid artery. Upper Extremities: Shoulder, acromioclavicular (AC) joint, elbow, peripheral nerves. Lower Extremities: Knee, ankle and Achilles tendon, foot. Pediatric applications.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K011608 · printed Nov 4, 2026
Cite this page
510(k) Report. “K011608: Model 235GE-64; Multi Purpose Flex Array Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K011608
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Page last updated Nov 3, 2026