510(k) Report

510(k) · Cleared

Cleared

Arthrocare Controller, Model H2000; Arthrocare Cable, Model H0970-02; Footswitch, Model H2000-04; Powercord, Model H2000

K011634510(k) SpecialCleared Jun 19, 200121-day reviewClass II21 CFR 878.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Arthrocare Corp. · GEI Electrosurgical, Cutting & Coagulation & Accessories

Cleared on Jun 19, 2001 as substantially equivalent to K000778 (Arthrocare Corp., 2000) and 4 other predicates after a 21-day review. Its family tree reaches back 1 generation to 2000. 41 later devices descend from it.

Decided
Jun 19, 2001
Review
21 days
Class
Class II
Product code
GEI
Recalls
None
Predicates
5

Its longest line of descent runs back 1 generation to K000778 (2000). 5 ancestors in all. 41 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor2000: 3 other ancestors2004: 2 descendants cleared2002: 1 descendant cleared2003: 1 descendant cleared2012: 3 descendants cleared2007: 4 descendants cleared2017: 3 descendants cleared2016: 5 descendants cleared2025: 2 descendants cleared2015: 2 descendants cleared2018: 4 descendants cleared2014: 1 descendant cleared2009: 4 descendants cleared2023: 2 descendants cleared2024: 2 descendants cleared2008: 3 descendants cleared2019: 1 descendant cleared2026: 1 descendant clearedK000778 · Entec Reflex Wand 55, Model E4055-01, E4045-01 · Arthrocare Corp. · 2000200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 7 descendants3 generations forward: 9 descendants4 generations forward: 7 descendants5 generations forward: 2 descendants6 generations forward: 2 descendants7 generations forward: 2 descendants8 generations forward: 6 descendants9 generations forward: 1 descendant10 generations forward: 1 descendant11 generations forward: 1 descendant12 generations forward: 1 descendant K000778 · Entec Reflex Wand 55, Model E4055-01, E4045-01 · Arthrocare Corp. · 20000+5+10
  1. Root · 1 generation backK000778 Entec Reflex Wand 55, Model E4055-01, E4045-01Arthrocare Corp. · 2000
  2. This deviceK011634 Arthrocare Controller, Model H2000; Arthrocare Cable, Model…Arthrocare Corp. · 2001
  3. Descendant · cites it directly · 40 of its ownK020832 Arthrocare Controller, Arthrocare Cable, Foot Control, Power Cord…Arthrocare Corp. · 2002
  4. Descendant · 2 generations on · 24 of its ownK040338 Arthrocare Controller, Cable, Foot Control, Power Cord, Wands…Arthrocare Corp. · 2004
  5. Descendant · 3 generations on · 21 of its ownK071963 Modification to: Arthrocare ArthrowandsArthrocare Corp. · 2007
  6. Descendant · 4 generations on · 20 of its ownK072865 Modificaton to: Arthrocare ArthrowandsArthrocare Corp. · 2007
  7. Descendant · 5 generations on · 19 of its ownK082323 Arthrocare ArthrowandsArthrocare Corp. · 2008

Showing 5 of 41 descendants. See all descendants

Descendants cleared per year

2002: 12003: 12004: 22007: 42008: 32009: 42012: 32014: 12015: 22016: 52017: 32018: 42019: 12023: 22024: 22025: 22026: 1
2002high 5 (2016) · low 0 (2005)2026

Most influential descendants

Showing 5 of 41 · See all
  • K020832Arthrocare Controller, Arthrocare Cable, Foot Control, Power Cord, WandsArthrocare Corp. · 2002 · cites it directly40descendants
  • K040338Arthrocare Controller, Cable, Foot Control, Power Cord, Wands, Models H0970-02…Arthrocare Corp. · 2004 · 2 generations on24descendants
  • K071963Modification to: Arthrocare ArthrowandsArthrocare Corp. · 2007 · 3 generations on21descendants
  • K072865Modificaton to: Arthrocare ArthrowandsArthrocare Corp. · 2007 · 4 generations on20descendants
  • K082323Arthrocare ArthrowandsArthrocare Corp. · 2008 · 5 generations on19descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K000778Entec Reflex Wand 55, Model E4055-01, E4045-01Arthrocare Corp.2000—
0 (this device)K011634Arthrocare Controller, Model H2000; Arthrocare Cable, Model H0970-02…Arthrocare Corp.2001—
+1K020832Arthrocare Controller, Arthrocare Cable, Foot Control, Power Cord, WandsArthrocare Corp.2002—
+2K040338Arthrocare Controller, Cable, Foot Control, Power Cord, Wands, Models…Arthrocare Corp.2004—
+3K071963Modification to: Arthrocare ArthrowandsArthrocare Corp.2007—
+4K072865Modificaton to: Arthrocare ArthrowandsArthrocare Corp.2007—
+5K082323Arthrocare ArthrowandsArthrocare Corp.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200030
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200420
200740
200830
200940
201230
201410
201520
201650
201730
201840
201910
202320
202420
202520
202610
FIG. 1 — Lineage of K011634, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEI device

  1. #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K000778Entec Reflex Wand 55, Model E4055-01, E4045-01
Summary page 1
…re® Orthopedic Electrosurgery System ArthroCare® Electrosurgery System Visage® Cosmetic Surgery System ArthroCare® Bipolar Loop Electrosurgical Device and Accessories K000778 KO001588 K001936 K003624 K010568 03 Intended Uses « The ENTec ReFlex Wand is indicated for ablation and coagul…
Arthrocare Corp.2000—
*K001588Arthrocare System 2000 Controller, Arthrocare System 2000 Cable, Arthrocare System 2000…
Summary page 3
…ce This Special 510(k) proposes a modification in materials to the Wand component of the Electrosurgery Systems, which were previously cleared in K000778 (May 3, 2000), K001588 (August 17, 2000), K001936 (July 19, 2000), K003624 (December 20, 2000), and K010568 (March 27, 2001). The technology, principle…
Arthrocare Corp.2000—
*K001936Arthrocare Controller, Arthrocare Cable, Footswitch, Powercord
Summary page 1
…ctrosurgery System ArthroCare® Electrosurgery System Visage® Cosmetic Surgery System ArthroCare® Bipolar Loop Electrosurgical Device and Accessories K000778 KO001588 K001936 K003624 K010568 03 Intended Uses « The ENTec ReFlex Wand is indicated for ablation and coagulation of soft tiss…
Arthrocare Corp.2000—
*K003624Refinity System, Refinity Handpiece and Cable, Refinity Footswitch, Refinity Power Cord…
Summary page 1
…ery System ArthroCare® Electrosurgery System Visage® Cosmetic Surgery System ArthroCare® Bipolar Loop Electrosurgical Device and Accessories K000778 KO001588 K001936 K003624 K010568 03 Intended Uses « The ENTec ReFlex Wand is indicated for ablation and coagulation of soft tissue in ot…
Arthrocare Corp.2000—
*K010568Arthrocare Urology Electrosurgery System
Summary page 1
…em ArthroCare® Electrosurgery System Visage® Cosmetic Surgery System ArthroCare® Bipolar Loop Electrosurgical Device and Accessories K000778 KO001588 K001936 K003624 K010568 03 Intended Uses « The ENTec ReFlex Wand is indicated for ablation and coagulation of soft tissue in otolaryngo…
Arthrocare Corp.2001—

Also cleared against K000778: 3 other devices →

What descends from it? (41)

See all 41

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K020832Arthrocare Controller, Arthrocare Cable, Foot Control, Power Cord, WandsArthrocare Corp.200240
K041810Serfas Energy SystemStryker Endoscopy200417

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 5 ancestors has a recall.
  • Of its descendants, K020832 (Arthrocare Corp., 2002) has gone furthest, with 40 descendants of its own.
  • 3 other devices also cite its predicate K000778.

How does its category compare?

All GEI devices

GEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GEI

52in 2025

2007: 502008: 612009: 422010: 462011: 352012: 392013: 482014: 492015: 472016: 642017: 522018: 472019: 482020: 592021: 462022: 552023: 652024: 592025: 522026 (partial year): 43
2007high 65 (2023) · low 35 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEI

113in 2025

2007: 51 days median2008: 71 days median2009: 130 days median2010: 109 days median2011: 135 days median2012: 133 days median2013: 136 days median2014: 103 days median2015: 123 days median2016: 108 days median2017: 72 days median2018: 93 days median2019: 93 days median2020: 105 days median2021: 146 days median2022: 150 days median2023: 104 days median2024: 125 days median2025: 113 days median2026 (partial year): 183 days median
2007high 183 (2026) · low 51 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEI

4in 2025

2007: 212008: 192009: 272010: 512011: 322012: 302013: 132014: 32015: 42016: 32017: 22018: 62019: 52020: 12021: 62022: 492023: 27, 4 Class I2024: 22, 10 Class I2025: 42026 (partial year): 8
2007high 51 (2010) · low 1 (2020)2026

Class I (14 since 2007) Class II/III not classified

Adverse event reports per year · GEI

7,592in 2025

2007: 2,7952008: 2,5562009: 3,5912010: 3,3772011: 4,4632012: 5,2162013: 4,8972014: 4,9082015: 4,9362016: 5,6162017: 6,0732018: 6,5452019: 7,0672020: 6,4902021: 6,3542022: 6,1032023: 7,1762024: 7,8972025: 7,592
2007high 7,897 (2024) · low 2,556 (2008)2025

MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075051212,795
20086171192,556
200942130273,591
201046109513,377
201135135324,463
201239133305,216
201348136134,897
20144910334,908
20154712344,936
20166410835,616
2017527226,073
2018479366,545
2019489357,067
20205910516,490
20214614666,354
202255150496,103
20236510427 (4)7,176
20245912522 (10)7,897
20255211347,592
2026431838—

What is it indicated for?

The ENTec ReFlex Wand is indicated for ablation and coagulation of soft tissue in otolaryngological (ENT) procedures, including the treatment of snoring, nasal airway obstruction by reduction of hypertrophic nasal turbinates, and submucosal tissue shrinkage. The ArthroCare System 2000 is indicated for resection, ablation, and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, spinal, and neurosurgical procedures. The…

Read the full statement (246 words)

The ENTec ReFlex Wand is indicated for ablation and coagulation of soft tissue in otolaryngological (ENT) procedures, including the treatment of snoring, nasal airway obstruction by reduction of hypertrophic nasal turbinates, and submucosal tissue shrinkage.

The ArthroCare System 2000 is indicated for resection, ablation, and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, spinal, and neurosurgical procedures.

The ENTec Surgery System is intended for ablation and coagulation of soft tissue in otorhinolaryngology (ENT) surgery including head, neck, oral, and sinus surgery.

The ArthroCare Orthopedic Electrosurgery System is indicated for resection, ablation, and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, and spinal procedures.

The ArthroCare Electrosurgery System is indicated for resection, ablation, and coagulation of soft tissue and hemostasis of blood vessels in general, plastic, and reconstructive surgery. It is intended to be used in procedures using conductive solutions, such as normal saline.

The Visage Cosmetic Surgery System is a bipolar electrosurgical device intended for general dermatologic surgery that may include skin resurfacing for the treatment of wrinkles, rhytids, and furrows, as well as soft tissue resection/removal and hemostasis/coagulation. It is intended to be used in procedures using conductive solutions such as normal saline.

The ArthroCare Bipolar Loop is indicated for resection, ablation, and excision, as well as hemostasis of blood vessels in patients requiring endoscopic surgery for general urological procedures including transurethral prostatectomy (TURP), transurethral incisions in the prostate (TUIP), and non-malignant tumors of the bladder wall.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011634: Arthrocare Controller, Model H2000; Arthrocare Cable, Model H0970-02; Footswitch, Model H2000-04; Powercord, Model H2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K011634

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026