Scanditronix Medical AB · IYE Accelerator, Linear, Medical

Cleared on Sep 5, 2001 as substantially equivalent to K945321 (Medical Physics Instrumentation, Inc., 1995) and 2 other predicates after a 90-day review. Its family tree reaches back 2 generations to 1994. 1 later device descends from it.

Decided
Sep 5, 2001
Review
90 days
Class
Class II
Product code
IYE
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K934303 (1994). 3 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor2009: 1 descendant clearedK934303 · RFA A-300 · Scanditronix, Inc. · 1994K961400 · Rfa-300, Lda Utility · Scanditronix Medical AB · 19971990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K961400 · Rfa-300, Lda Utility · Scanditronix Medical AB · 1997K934303 · RFA A-300 · Scanditronix, Inc. · 19940
  1. Root · 2 generations backK934303 RFA A-300Scanditronix, Inc. · 1994
  2. 1 generation backK961400 Rfa-300, Lda UtilityScanditronix Medical AB · 1997
  3. This deviceK011763 OmnidosScanditronix Medical AB · 2001
  4. Descendant · cites it directly · 0 of its ownK092018 Omnipro InclineIba Dosimetry GmbH · 2009

Most influential descendants

Showing 1 of 1 · See all
  • K092018Omnipro InclineIba Dosimetry GmbH · 2009 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K934303RFA A-300Scanditronix, Inc.1994—
−1K961400Rfa-300, Lda UtilityScanditronix Medical AB1997—
0 (this device)K011763OmnidosScanditronix Medical AB2001—
+1K092018Omnipro InclineIba Dosimetry GmbH2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
FIG. 1 — Lineage of K011763, 1994–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYE device

  1. #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K945321Wellhofer WP700 V. 3.2
Summary page 1
…therapy system, §892,5750; X-ray radiation therapy system, §892,5900; and Medical charged-particle radiation therapy system, §892.5050. WP700 (Wellhsfer Dosimetrie) FDA K945321/S1, 1995, 29" of March. RFA-300 (Scanditronix Medical) FDA K934303/S1, 510(k) Aug 1994, RFA-300, LDA Utility (Scanditronix Medi…
Medical Physics Instrumentation, Inc.19952
*K934303RFA A-300
Summary page 1
…; and Medical charged-particle radiation therapy system, §892.5050. WP700 (Wellhsfer Dosimetrie) FDA K945321/S1, 1995, 29" of March. RFA-300 (Scanditronix Medical) FDA K934303/S1, 510(k) Aug 1994, RFA-300, LDA Utility (Scanditronix Medical) FDA K961400: Jan. 1997 ‘The Scanditronix & Wellhéfer OmniDos i…
Scanditronix, Inc.1994—
*K961400Rfa-300, Lda Utility
Summary page 1
…llhsfer Dosimetrie) FDA K945321/S1, 1995, 29" of March. RFA-300 (Scanditronix Medical) FDA K934303/S1, 510(k) Aug 1994, RFA-300, LDA Utility (Scanditronix Medical) FDA K961400: Jan. 1997 ‘The Scanditronix & Wellhéfer OmniDos is a General Dosimetry ~Systenr similar to Wellhsfer Dosimetrie: WP700, FDA K…
Scanditronix Medical AB1997—

Also cleared against K945321: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092018Omnipro InclineIba Dosimetry GmbH20090

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 4.7 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K092018 (Iba Dosimetry GmbH, 2009) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K945321.

How does its category compare?

All IYE devices

IYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYE

12in 2025

2007: 232008: 142009: 202010: 232011: 112012: 282013: 182014: 202015: 202016: 212017: 232018: 212019: 192020: 202021: 192022: 122023: 182024: 92025: 122026 (partial year): 14
2007high 28 (2012) · low 9 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYE

170in 2025

2007: 44 days median2008: 69 days median2009: 63 days median2010: 74 days median2011: 94 days median2012: 106 days median2013: 88 days median2014: 100 days median2015: 108 days median2016: 97 days median2017: 94 days median2018: 58 days median2019: 83 days median2020: 67 days median2021: 86 days median2022: 172 days median2023: 129 days median2024: 239 days median2025: 170 days median2026 (partial year): 120 days median
2007high 239 (2024) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYE

1in 2025

2007: 782008: 492009: 222010: 272011: 732012: 202013: 112014: 142015: 82016: 72017: 72018: 72019: 22020: 42021: 52022: 32023: 72024: 12025: 12026 (partial year): 4
2007high 78 (2007) · low 1 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYE

101in 2025

2007: 1552008: 1142009: 1742010: 2462011: 2802012: 1282013: 962014: 1242015: 1002016: 972017: 1252018: 852019: 912020: 742021: 682022: 662023: 1282024: 812025: 101
2007high 280 (2011) · low 66 (2022)2025

MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007234478155
2008146949114
2009206322174
2010237427246
2011119473280
20122810620128
201318881196
20142010014124
2015201088100
20162197797
201723947125
20182158785
20191983291
20202067474
20211986568
202212172366
2023181297128
20249239181
2025121701101
2026141204—

What is it indicated for?

OmniDos is a system software utilising hardware components to measure radiation dose distribution. The hardware consists of water phantoms, air scanners, film scanners/ digitizers and single or array detectors. The hardware comes from Scanditronix Medical, the sister company Wellhofer Dosimetry and from 3rd party vendors.

OmniDos is used to accurately analyse and handle the measured dose distribution in quality assurance purposes, for calibration of radiation devices, as input data to Treatment Planning Systems, for acceptance testing, beam tuning and in research.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K011763: Omnidos.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011763

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026