Howmedica Osteonics Corp. · LXT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
Cleared on Jul 13, 2001 after a 22-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below).
- Decided
- Jul 13, 2001
- Review
- 22 days
- Class
- Class II
- Product code
- LXT
- Recalls
- None
- Predicates
- 1
The summary cites one number, which could not be confirmed as its predicate (see the table below).
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LXT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LXT device
- #1 K230067 Para-Fix External Fixation Systemscore 6.4 · 2 generations · no Class I recall
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| Kept off the family tree | K000197 | FDA’s K000197 is Cortek Cystoscope Our OCR of the scanned summary read K000197, FDA’s number for Cortek Cystoscope (Cortek Endoscopy, Inc.). Its FDA name has none of the distinctive words the summary uses for the device it names, “Hoffmann® II Hybrid Ring Clamp”. Kept off the family tree. Summary page 1…xation appliances and accessories, 21 CFR §888.3030 Predicate Device Identification The Hoffmann® II Hybrid Ring Clamp was determined substantially equivalent via 510(k) K000197.. Device Description The Hoffmann® IT Hybrid Clamp is being modified to address issues in manufacturing. Intended Use: This su… | 2000 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LXT devicesLXT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LXT
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · LXT
Too few LXT 510(k)s in any year since 2007 to give a median.
Recalls per year · LXT
2in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LXT
7in 2025
MAUDE reports naming product code LXT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 1 | 26 |
| 2008 | 1 | — | 0 | 58 |
| 2009 | 1 | — | 7 | 41 |
| 2010 | 0 | — | 0 | 33 |
| 2011 | 1 | — | 0 | 85 |
| 2012 | 0 | — | 0 | 42 |
| 2013 | 2 | — | 0 | 39 |
| 2014 | 0 | — | 0 | 36 |
| 2015 | 0 | — | 0 | 35 |
| 2016 | 0 | — | 0 | 38 |
| 2017 | 0 | — | 0 | 66 |
| 2018 | 0 | — | 2 | 73 |
| 2019 | 0 | — | 0 | 40 |
| 2020 | 0 | — | 0 | 32 |
| 2021 | 0 | — | 0 | 24 |
| 2022 | 0 | — | 0 | 21 |
| 2023 | 1 | — | 0 | 18 |
| 2024 | 0 | — | 0 | 27 |
| 2025 | 0 | — | 0 | 7 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Hoffmann® II Hybrid External Fixation System is intended to be used in conjunction with the Apex™ Half Pins of the Hoffmann® External Fixation System and Kirschner Wires of the Monticelli Spinelli™ External Fixation System, and may be used as a Hybrid External Fixation System with the components of the Hoffmann® II External Fixation System and the Monotube® TRIAX"™ External Fixation System. This device is used to provide stabilization of open and/or…
Read the full statement (135 words)
The Hoffmann® II Hybrid External Fixation System is intended to be used in conjunction with the Apex™ Half Pins of the Hoffmann® External Fixation System and Kirschner Wires of the Monticelli Spinelli™ External Fixation System, and may be used as a Hybrid External Fixation System with the components of the Hoffmann® II External Fixation System and the Monotube® TRIAX"™ External Fixation System.
This device is used to provide stabilization of open and/or unstable fractures and where soft tissue injury may preclude the use of other fracture treatments such as IM rods, casts, or other means of internal fixation. The indications for use of metallic external fixation devices include:
• Bone fracture fixation
• Osteotomy
• Arthrodesis
• Correction of deformity
• Revision procedure where other treatments or devices have been unsuccessful
• Bone reconstruction procedures
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K011948 · printed Nov 4, 2026
Cite this page
510(k) Report. “K011948: Hoffman II Hybrid Ring Clamp.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K011948
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Page last updated Nov 3, 2026