510(k) · Cleared
ClearedClearmedical/Aircast Venaflow Calf Cuff, Clearmedical Aircast XL Venaflow Calf Cuff, Clearmedical/Aircast Venaflow Thigh
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Clearmedical, Inc. · JOW Sleeve, Limb, Compressible
Cleared on Feb 6, 2002 after a 177-day review. The FDA summary names its predicate without a number.
- Decided
- Feb 6, 2002
- Review
- 177 days
- Class
- Class II
- Product code
- JOW
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JOW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JOW device
- #1 K253555 Flexitouch® Plus Advanced Pneumatic…score 14.8 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Aircast VenaFlow Cuffs (3010, 3012, 3015, and 3016) Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JOW devicesJOW Sleeve, Limb, Compressible: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JOW
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JOW
168in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JOW
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JOW
24in 2025
MAUDE reports naming product code JOW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 66 | 0 | 12 |
| 2008 | 4 | 112 | 7 | 36 |
| 2009 | 3 | 84 | 0 | 45 |
| 2010 | 18 | 71 | 2 | 66 |
| 2011 | 11 | 104 | 3 | 50 |
| 2012 | 13 | 63 | 2 | 100 |
| 2013 | 17 | 94 | 0 | 169 |
| 2014 | 16 | 91 | 0 | 93 |
| 2015 | 10 | 160 | 0 | 137 |
| 2016 | 9 | 121 | 0 | 150 |
| 2017 | 9 | 116 | 1 | 149 |
| 2018 | 11 | 136 | 0 | 114 |
| 2019 | 11 | 88 | 1 | 102 |
| 2020 | 14 | 158 | 0 | 50 |
| 2021 | 16 | 132 | 0 | 34 |
| 2022 | 7 | 80 | 0 | 27 |
| 2023 | 6 | 160 | 0 | 57 |
| 2024 | 8 | 197 | 0 | 30 |
| 2025 | 7 | 168 | 0 | 24 |
| 2026 | 6 | 252 | 0 | — |
What is it indicated for?
To reduce the incidence of deep vein thrombosis, reduce pain and swelling after injury or surgery and increase arterial blood flow.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K012601 · printed Nov 4, 2026
Cite this page
510(k) Report. “K012601: Clearmedical/Aircast Venaflow Calf Cuff, Clearmedical Aircast XL Venaflow Calf Cuff, Clearmedical/Aircast Venaflow Thigh.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K012601
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Page last updated Nov 3, 2026