510(k) Report

510(k) · Cleared

Cleared

Reprocessed Autosuture Unipolar Laparoscopic/Endoscopic Instruments

K012603510(k) TraditionalCleared Nov 7, 200186-day reviewClass II21 CFR 878.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Alliance Medical Corp. · NUJ Electrosurgical, Cutting & Coagulation Accessories, Laparoscopic & Endoscopic, Reprocessed

Cleared on Nov 7, 2001 after an 86-day review. The FDA summary names no predicate by number.

Decided
Nov 7, 2001
Review
86 days
Class
Class II
Product code
NUJ
Recalls
None
Predicates
0

The FDA summary names no predicate by number.

FIG. 1 — Lineage of K012603Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NUJ device

  1. #1 K220411 Reprocessed LigaSure Curved, Small Jaw, Open…score 8.4 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All NUJ devices

NUJ Electrosurgical, Cutting & Coagulation Accessories, Laparoscopic & Endoscopic, Reprocessed: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NUJ

1in 2024

2008: 12010: 12011: 22012: 22013: 22014: 12015: 22016: 52017: 32018: 72019: 12022: 22023: 12024: 1
2007high 7 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NUJ

88in 2018

2016: 155 days median2017: 49 days median2018: 88 days median
2007high 155 (2016) · low 49 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NUJ

11in 2025

2008: 22023: 32025: 11
2007high 11 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NUJ

38in 2025

2007: 42008: 42009: 12010: 92011: 22012: 392013: 1612014: 742015: 252016: 522017: 512018: 142019: 202020: 592021: 472022: 312023: 272024: 922025: 38
2007high 161 (2013) · low 1 (2009)2025

MAUDE reports naming product code NUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20081—24
20090—01
20101—09
20112—02
20122—039
20132—0161
20141—074
20152—025
20165155052
2017349051
2018788014
20191—020
20200—059
20210—047
20222—031
20231—327
20241—092
20250—1138
20260—0—

What is it indicated for?

Reprocessed Unipolar Laparoscopic/Endoscopic Instruments, including scissors, dissectors, and graspers, are to be used for patients requiring minimally invasive surgical procedures to manipulate and manage internal soft tissue by grasping, cutting, dissecting, cauterizing, or coagulating tissue.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K012603: Reprocessed Autosuture Unipolar Laparoscopic/Endoscopic Instruments.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K012603

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Page last updated Nov 3, 2026