510(k) Report

510(k) · Cleared

Cleared

Lyphochek Coagulation Control Level 1, Lyphochek Coagulation Level 2, Lyphochek Coagulation Level 3, Models 781,782,783

K012722510(k) TraditionalCleared Sep 18, 200134-day reviewClass II21 CFR 864.5425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Rad · GGN Plasma, Coagulation Control

Cleared on Sep 18, 2001 as substantially equivalent to K990858 (Bio-Rad, 1999) after a 34-day review. Its family tree reaches back 3 generations to 1982. 1 later device descends from it.

Decided
Sep 18, 2001
Review
34 days
Class
Class II
Product code
GGN
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K820450 (1982). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK820450 ThromboscreenPacific Hemostasis · 1982
  2. 2 generations backK964963 Lyphochek Coagulation ControlBio-Rad · 1997
  3. 1 generation backK990858 Lypochek Coagulation Control, Model Nos. 787, 788, 789Bio-Rad · 1999
  4. This deviceK012722 Lyphochek Coagulation Control Level 1, Lyphochek Coagulation Level…Bio-Rad · 2001
  5. Descendant · cites it directly · 0 of its ownK032611 Lyphochek Coagulation Control, Level 4, Model 743Bio-Rad · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K032611Lyphochek Coagulation Control, Level 4, Model 743Bio-Rad · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K820450ThromboscreenPacific Hemostasis1982—
−2K964963Lyphochek Coagulation ControlBio-Rad1997—
−1K990858Lypochek Coagulation Control, Model Nos. 787, 788, 789Bio-Rad1999—
0 (this device)K012722Lyphochek Coagulation Control Level 1, Lyphochek Coagulation Level 2…Bio-Rad2001—
+1K032611Lyphochek Coagulation Control, Level 4, Model 743Bio-Rad2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K012722, 1982–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GGN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990858Lypochek Coagulation Control, Model Nos. 787, 788, 789
Summary page 1
…ation Number: 21 CFR 864.5425 Device to Which Substantial Equivalence is Claimed Lyphochek® Coagulation Control Bio-Rad Laboratories Irvine, California Docket Number: K990858 Description of Device Lyphochek® Coagulation Control is prepared from human plasma, with added purified biochemical and preserv…
Bio-Rad1999—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032611Lyphochek Coagulation Control, Level 4, Model 743Bio-Rad20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 2 companies; a new generation was cleared every 2.4 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K032611 (Bio-Rad, 2003) has gone furthest, with 0 descendants of its own.

How does its category compare?

All GGN devices

GGN Plasma, Coagulation Control: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GGN

4in 2017

2007: 32008: 12009: 22010: 32011: 22012: 12013: 32014: 22016: 22017: 4
2007high 4 (2017) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GGN

96in 2017

2007: 47 days median2010: 23 days median2013: 441 days median2017: 96 days median
2007high 441 (2013) · low 23 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GGN

1in 2019

2010: 42011: 12013: 32019: 12026 (partial year): 2
2007high 4 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GGN

4in 2018

2009: 372010: 172011: 302012: 102013: 92014: 52015: 102016: 92017: 112018: 4
2007high 37 (2009) · low 0 (2007)2025

MAUDE reports naming product code GGN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200734700
20081—00
20092—037
2010323417
20112—130
20121—010
2013344139
20142—05
20150—010
20162—09
2017496011
20180—04
20190—10
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—2—

What is it indicated for?

Lyphochek® Coagulation Control is intended for use as a quality control plasma to monitor the precision of citrated coagulation systems.

Prothrombin Time (PT), Activated Partial Thromboplastin Time (APTT), Fibrinogen and Antithrombin Ill (AT lil) are assayed on the MLA ELECTRA series. Thrombin Time (TT) is assayed on the Dade BBL Fibrometer (Becton Dickinson).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K012722: Lyphochek Coagulation Control Level 1, Lyphochek Coagulation Level 2, Lyphochek Coagulation Level 3, Models 781,782,783.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K012722

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026