Becton Dickinson Infusion Therapy Systems, Inc. · FPA Set, Administration, Intravascular
Cleared on Apr 16, 2002 as substantially equivalent to K970855 (Icu Medical, Inc., 1997) after a 162-day review. Its family tree reaches back 1 generation to 1997. 2 later devices descend from it. It has been recalled 11 times.
- Decided
- Apr 16, 2002
- Review
- 162 days
- Class
- Class II
- Product code
- FPA
- Recalls
- 11
- Predicates
- 1
Its longest line of descent runs back 1 generation to K970855 (1997). 2 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK970855 Clave ConnectorIcu Medical, Inc. · 1997 · Recalled
- This deviceK013621 BD Saf-T PRN Luer Activated Valve, Model 385100Becton Dickinson Infusion Therapy Systems, Inc. · 2002
- Descendant · cites it directly · 1 of its ownK142527 Extension Set with BD Q-Syte Luer Access Split SeptumAcacia, Inc. · 2014
- Descendant · 2 generations on · 0 of its ownK202672 Precision Delivery Infusion SetQuest Medical, Inc. · 2021 · Recalled
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K970855 | Clave Connector | Icu Medical, Inc. | 1997 | 52 |
| 0 (this device) | K013621 | BD Saf-T PRN Luer Activated Valve, Model 385100 | Becton Dickinson Infusion Therapy Systems, Inc. | 2002 | — |
| +1 | K142527 | Extension Set with BD Q-Syte Luer Access Split Septum | Acacia, Inc. | 2014 | — |
| +2 | K202672 | Precision Delivery Infusion Set | Quest Medical, Inc. | 2021 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2021 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K970855 | Clave ConnectorSummary page 1…9 October 25, 2001 BD Saf-T PRN Luer Activated Valve Luer Activated Valve Accessory to an Intravascular Administration Set Clave® Connector C-1000 |ICU Medical Inc. K970855 Description of the BD Saf-T PRN Luer Activated Valve: The BD Saf-T PRN Luer Activated Valve is a closed system that opens when… | 1997 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K142527 | Extension Set with BD Q-Syte Luer Access Split Septum | 2014 | 1 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Feb 19, 2015 | Class II | Z-1317-2015 | Process control | Becton Dickinson received an elevated number of complaints for blood or infusate/medication leakage due to tearing of the silicone septum. |
| Nov 6, 2009 | Not classified | Z-1075-2010 | Nonconforming Material/Component | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Nov 6, 2009 | Not classified | Z-1073-2010 | Nonconforming Material/Component | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Nov 6, 2009 | Not classified | Z-1074-2010 | Nonconforming Material/Component | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0751-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0754-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0755-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0753-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0756-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0752-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
| Oct 19, 2009 | Not classified | Z-0750-2010 | Process control | Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism. |
The 5 latest of 11 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
An intravascular administration set is a device used to administer fluids from a container to a patient’s vascular system through a needle or catheter. An administration set may include the needle or catheter, tubing, flow regulator, drip chamber, infusion line filter, 1V set stopcock, fluid delivery tubing, connectors between parts of the set, side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an IV~ bag or other infusion fluid container.
The BD Saf-T PRN Luer Activated Valve needleless connector is an accessory to an intravascular administration set that permits injection, gravity flow or withdrawal of fluids.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K013621 · printed Nov 6, 2026
Cite this page
510(k) Report. “K013621: BD Saf-T PRN Luer Activated Valve, Model 385100.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K013621
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026