510(k) · Cleared

Cleared

Endoscopic Multi-Fire Clip Applier

K013889510(k) TraditionalCleared Feb 7, 200276-day reviewClass II21 CFR 876.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Inscope, LLC · PKL Hemostatic Metal Clip For The Gi Tract

Cleared on Feb 7, 2002 as substantially equivalent to K963160 (Olympus America, Inc., 1997) after a 76-day review. Its family tree reaches back 1 generation to 1997.

Decided
Feb 7, 2002
Review
76 days
Class
Class II
Product code
PKL
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K963160 (1997). No later device cites it as a predicate yet.

K963160 · HX-5/6-1 Endoscopic Clipping Device · Olympus America, Inc. · 199719961998200020022004
  1. Root · 1 generation backK963160 HX-5/6-1 Endoscopic Clipping DeviceOlympus America, Inc. · 1997
  2. This deviceK013889 Endoscopic Multi-Fire Clip ApplierInscope, LLC · 2002
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K963160HX-5/6-1 Endoscopic Clipping DeviceOlympus America, Inc.1997—
0 (this device)K013889Endoscopic Multi-Fire Clip ApplierInscope, LLC2002—
FIG. 1 — Lineage of K013889, 1997–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PKL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PKL device

  1. #1 K202333 Lockado Repositionable Hemostasis Clipscore 17.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K963160HX-5/6-1 Endoscopic Clipping Device
Summary page 1
…tantially equivalent to the legally marketed Olympus HX-5/6-1 Endoscopic Clipping Device manufactured and marketed by the Olympus Optical Company, Ltd pursuant to 510(k) K963160. Device Description The InScope Endoscopic Multi-Fire Clip Applier is designed for gastrointestinal endo- scopic clipping for m…
Olympus America, Inc.1997—

Also cleared against K963160: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 3 other devices also cite its predicate K963160.

How does its category compare?

All PKL devices

PKL Hemostatic Metal Clip For The Gi Tract: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · PKL

6in 2025

2010: 22012: 32013: 22014: 12015: 32016: 12017: 22018: 52019: 42020: 62021: 22022: 92023: 22024: 82025: 62026 (partial year): 7
2007high 9 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PKL

162in 2025

2012: 102 days median2015: 143 days median2018: 116 days median2019: 231 days median2020: 164 days median2022: 259 days median2024: 181 days median2025: 162 days median2026 (partial year): 231 days median
2007high 259 (2022) · low 102 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PKL

1in 2019

2019: 1
2007high 1 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PKL

1,170in 2025

2012: 12014: 42015: 342016: 1282017: 3982018: 3932019: 6992020: 5042021: 6682022: 5222023: 8632024: 1,2162025: 1,170
2007high 1,216 (2024) · low 0 (2007)2025

MAUDE reports naming product code PKL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20102—00
20110—00
2012310201
20132—00
20141—04
20153143034
20161—0128
20172—0398
201851160393
201942311699
202061640504
20212—0668
202292590522
20232—0863
2024818101,216
2025616201,170
202672310—

What is it indicated for?

The Endoscopic Multi-fire Clip Applier was designed to be used with an endoscope to place clips in the gastrointestinal (GI) tract for the purpose of endoscopic marking, hemostasis of mucosal and submucosal defects < 3 cm, bleeding ulcers, arteries <2 mm, polyps < 1.5 cm in diameter, and anchoring to affix jejunal feeding tubes to the wall of the small bowel. The device is not intended for repair of gastrointestinal tract lumenal perforations.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K013889: Endoscopic Multi-Fire Clip Applier.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K013889

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026