510(k) · Cleared
ClearedEdwards Lifesciences Percutaneous Sheath Introducers with Oligon Material
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Edwards Lifesciences, LLC · DYB Introducer, Catheter
Cleared on Mar 8, 2002 after an 88-day review. The FDA summary names its predicate without a number.
- Decided
- Mar 8, 2002
- Review
- 88 days
- Class
- Class II
- Product code
- DYB
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DYB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DYB device
- #1 K251051 AuST Steerable Sheathscore 18.0 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Baxter Hemostasis Valve Introducers Named without a submission number | |
| * | — | Baxter Healthcare Intro-Flex® Sheath Introducers with AMC Thromboshield Named without a submission number | |
| * | — | Baxter Healthcare Vantex™ Central Venous Catheters with Oligon™ material Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All DYB devicesDYB Introducer, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DYB
16in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DYB
63in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DYB
3in 2025
Class I (48 since 2007) Class II/III not classified
Adverse event reports per year · DYB
4,539in 2025
MAUDE reports naming product code DYB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 95 | 15 | 316 |
| 2008 | 17 | 37 | 9 | 423 |
| 2009 | 14 | 52 | 25 | 399 |
| 2010 | 18 | 123 | 18 | 445 |
| 2011 | 17 | 100 | 4 | 628 |
| 2012 | 22 | 128 | 3 | 898 |
| 2013 | 26 | 118 | 5 (1) | 743 |
| 2014 | 30 | 122 | 2 | 780 |
| 2015 | 17 | 129 | 2 (1) | 913 |
| 2016 | 19 | 95 | 45 (3) | 1,234 |
| 2017 | 24 | 70 | 22 (1) | 1,672 |
| 2018 | 19 | 156 | 1 | 1,903 |
| 2019 | 18 | 47 | 2 | 2,450 |
| 2020 | 9 | 49 | 21 (21) | 2,465 |
| 2021 | 12 | 78 | 6 | 2,835 |
| 2022 | 13 | 143 | 2 | 4,084 |
| 2023 | 15 | 55 | 10 | 3,775 |
| 2024 | 18 | 56 | 2 | 3,931 |
| 2025 | 16 | 63 | 3 | 4,539 |
| 2026 | 17 | 59 | 23 (21) | — |
What is it indicated for?
The Edwards Lifesciences Percutaneous Sheath Introducers with Oligon™ material are indicated for use in patients requiring access of the venous system and to facilitate catheter insertion (e.g. pulmonary artery or infusion catheter).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K014052 · printed Nov 6, 2026
Cite this page
510(k) Report. “K014052: Edwards Lifesciences Percutaneous Sheath Introducers with Oligon Material.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K014052
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Page last updated Nov 3, 2026