510(k) Report

510(k) · Cleared

Cleared

Numed Coefficient PTV Catheters

K014124510(k) SpecialCleared Jan 16, 200230-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

NuMED, Inc. · OMZ Pulmonary (Pulmonic) Valvuloplasty Catheters/Percutaneous Valvuloplasty Catheter

Cleared on Jan 16, 2002 after a 30-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.

Decided
Jan 16, 2002
Review
30 days
Class
Class II
Product code
OMZ
Recalls
None
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared2016: 1 descendant clearedReference device: K931009 · Tyshak Peripheral Balloon Dilation Catheter · NuMED, Inc. · 1993 · recalledReference device: K991977 · Tyshak, Model 102 and Z-Med, Model 302 · NuMED, Inc. · 2000200020052010201520202025
  1. This deviceK014124 Numed Coefficient PTV CathetersNuMED, Inc. · 2002
  2. Descendant · cites it directly · 1 of its ownK040830 Pta, PTV, Atrioseptostomy, Angiographic, Sizing CathetersNuMED, Inc. · 2004
  3. Descendant · 2 generations on · 0 of its ownK153069 Edwards Balloon CatheterEdwards Lifesciences · 2016

Most influential descendants

Showing 2 of 2 · See all
  • K040830Pta, PTV, Atrioseptostomy, Angiographic, Sizing CathetersNuMED, Inc. · 2004 · cites it directly1descendant
  • K153069Edwards Balloon CatheterEdwards Lifesciences · 2016 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K014124Numed Coefficient PTV CathetersNuMED, Inc.2002—
+1K040830Pta, PTV, Atrioseptostomy, Angiographic, Sizing CathetersNuMED, Inc.2004—
+2K153069Edwards Balloon CatheterEdwards Lifesciences2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
201610
FIG. 1 — Lineage of K014124, 2002–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OMZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—NuMED Z-MED PTV Catheter
Named without a submission number
—
†K931009Tyshak Peripheral Balloon Dilation CatheterNuMED, Inc.19931
†K991977Tyshak, Model 102 and Z-Med, Model 302NuMED, Inc.2000—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K040830Pta, PTV, Atrioseptostomy, Angiographic, Sizing CathetersNuMED, Inc.20041

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K040830 (NuMED, Inc., 2004) has gone furthest, with 1 descendant of its own.

How does its category compare?

All OMZ devices

OMZ Pulmonary (Pulmonic) Valvuloplasty Catheters/Percutaneous Valvuloplasty Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · OMZ

1in 2016

2010: 12012: 12013: 12016: 1
2007high 1 (2010) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OMZ

Too few OMZ 510(k)s in any year since 2007 to give a median.

Recalls per year · OMZ

No recall names OMZ since 2007.

Adverse event reports per year · OMZ

3in 2024

2013: 12014: 12015: 32016: 22018: 12019: 42021: 52023: 12024: 3
2007high 5 (2021) · low 0 (2007)2025

MAUDE reports naming product code OMZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20101—00
20110—00
20121—00
20131—01
20140—01
20150—03
20161—02
20170—00
20180—01
20190—04
20200—00
20210—05
20220—00
20230—01
20240—03
20250—00
20260—0—

What is it indicated for?

This catheter is recommended for Percutaneous Transluminal Valvuloplasty

(PTV) of the pulmonary valve.

= A patient with isolated pulmonary stenosis

= A patient with valvular pulmonary stenosis with other minor congenital

heart disease that does not require surgical intervention.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K014124: Numed Coefficient PTV Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K014124

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026