Palmo Thermoregulation Interface Accessory

K014210510(k) TraditionalCleared Aug 16, 2002238-day reviewClass II21 CFR 870.5900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Avacore Technologies, Inc. · DWJ System, Thermal Regulating

Cleared on Aug 16, 2002 as substantially equivalent to K970376 (Lake Region Mfg., Inc., 1997) after a 238-day review. Its family tree reaches back 1 generation to 1997. 1 later device descends from it.

Decided
Aug 16, 2002
Review
238 days
Class
Class II
Product code
DWJ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K970376 (1997). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2003: 1 descendant clearedK970376 · Ptca Guidewire · Lake Region Mfg., Inc. · 19971995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K970376 · Ptca Guidewire · Lake Region Mfg., Inc. · 19970
  1. Root · 1 generation backK970376 Ptca GuidewireLake Region Mfg., Inc. · 1997
  2. This deviceK014210 Palmo Thermoregulation Interface AccessoryAvacore Technologies, Inc. · 2002
  3. Descendant · cites it directly · 0 of its ownK023934 Rapid Thermal Exchange SystemAvacore Technologies, Inc. · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K023934Rapid Thermal Exchange SystemAvacore Technologies, Inc. · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K970376Ptca GuidewireLake Region Mfg., Inc.1997—
0 (this device)K014210Palmo Thermoregulation Interface AccessoryAvacore Technologies, Inc.2002—
+1K023934Rapid Thermal Exchange SystemAvacore Technologies, Inc.2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K014210, 1997–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWJ device

  1. #1 K260278 ThermAffyx (TM) Patient Safety Systemscore 12.8 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K970376Ptca Guidewire
Summary page 1
…evices Cincinnati Subzero Blanketrol I1 Hyper-Hyopthermia System Preamendment Aquarius Thermo-STAT System K970376 Device Description The Palmo consists of three main parts: 1) a vacuum chamber that contains the 2) thermal exchange surface and…
Lake Region Mfg., Inc.1997—
*—Cincinnati Subzero Blanketrol II Hyper-Hypothermia System
Named without a submission number
—

Also cleared against K970376: 6 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K023934Rapid Thermal Exchange SystemAvacore Technologies, Inc.20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K023934 (Avacore Technologies, Inc., 2003) has gone furthest, with 0 descendants of its own.
  • 6 other devices also cite its predicate K970376.

How does its category compare?

All DWJ devices

DWJ System, Thermal Regulating: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DWJ

3in 2025

2007: 42008: 32009: 32010: 82011: 42012: 52013: 52014: 42016: 22017: 52018: 32019: 22020: 52021: 22022: 22023: 62024: 22025: 32026 (partial year): 5
2007high 8 (2010) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWJ

131in 2025

2007: 106 days median2008: 73 days median2009: 106 days median2010: 134 days median2011: 180 days median2012: 69 days median2013: 77 days median2014: 131 days median2017: 153 days median2018: 95 days median2020: 30 days median2023: 42 days median2025: 131 days median2026 (partial year): 99 days median
2007high 180 (2011) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DWJ

3in 2024

2009: 62010: 22011: 72012: 12013: 22015: 12017: 32018: 52019: 32020: 22021: 12022: 52024: 32026 (partial year): 3
2007high 7 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DWJ

2,384in 2025

2007: 522008: 402009: 712010: 1042011: 1362012: 1062013: 732014: 1162015: 2452016: 1,4002017: 1,4732018: 1,5172019: 2,2942020: 2,5462021: 2,6892022: 3,2262023: 3,4552024: 3,3292025: 2,384
2007high 3,455 (2023) · low 40 (2008)2025

MAUDE reports naming product code DWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074106052
2008373040
20093106671
201081342104
201141807136
20125691106
2013577273
201441310116
20150—1245
20162—01,400
2017515331,473
201839551,517
20192—32,294
202053022,546
20212—12,689
20222—53,226
202364203,455
20242—33,329
2025313102,384
20265993—

What is it indicated for?

The Palmo Thermoregulation Interface Accessory is designed to noninvasively lower or raise a patient’s temperature andor maintain a desired patient temperature. This is accomplished with local application of negative pressure and heatingcooling to a distal appendage.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K014210: Palmo Thermoregulation Interface Accessory.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K014210

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026