7MM Extended Length Endoscope,Dissection Tips, Models VH-1111, VH-1114

K014250510(k) TraditionalCleared Jan 10, 200215-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Guidant Corp. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Jan 10, 2002 as substantially equivalent to K960637 (Origin Medsystems, Inc., 1996) and 1 other predicate after a 15-day review. Its family tree reaches back 2 generations to 1997. 1 later device descends from it.

Decided
Jan 10, 2002
Review
15 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K964171 (1997). 3 ancestors in all, the oldest K960637 (1996). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1996: 1 other ancestor2020: 1 descendant clearedK964171 · Vasoview Balloon Dissection System · Origin Medsystems, Inc. · 1997K981700 · Vasoview Dissection/Vessel Harvesting System · Origin Medsystems, Inc. · 19981995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K981700 · Vasoview Dissection/Vessel Harvesting System · Origin Medsystems, Inc. · 1998K964171 · Vasoview Balloon Dissection System · Origin Medsystems, Inc. · 19970
  1. Root · 2 generations backK964171 Vasoview Balloon Dissection SystemOrigin Medsystems, Inc. · 1997
  2. 1 generation backK981700 Vasoview Dissection/Vessel Harvesting SystemOrigin Medsystems, Inc. · 1998
  3. This deviceK014250 7MM Extended Length Endoscope,Dissection Tips, Models VH-1111, VH-1114Guidant Corp. · 2002
  4. Descendant · cites it directly · 0 of its ownK191930 7 mm Extended Length EndoscopeMaquet Cardiovascular, LLC · 2020

Most influential descendants

Showing 1 of 1 · See all
  • K1919307 mm Extended Length EndoscopeMaquet Cardiovascular, LLC · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K964171Vasoview Balloon Dissection SystemOrigin Medsystems, Inc.1997—
−1K981700Vasoview Dissection/Vessel Harvesting SystemOrigin Medsystems, Inc.1998—
0 (this device)K0142507MM Extended Length Endoscope,Dissection Tips, Models VH-1111, VH-1114Guidant Corp.2002—
+1K1919307 mm Extended Length EndoscopeMaquet Cardiovascular, LLC2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
FIG. 1 — Lineage of K014250, 1997–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K9606375MM Endoscope
Summary page 2
…al Equivalence The 7 mm Extended Length Endoscope with Dissection Tip is substantially equivalent to the 5mm Endoscope, cleared by the Food and Drug Administration under K960637 on June 14, 1996, and the VasoView™ Dissection Cannula, K981700, cleared on February 18, 1998. The design of the 7 mm Extended Le…
Origin Medsystems, Inc.1996—
*K981700Vasoview Dissection/Vessel Harvesting System
Summary page 2
…n Tip is substantially equivalent to the 5mm Endoscope, cleared by the Food and Drug Administration under K960637 on June 14, 1996, and the VasoView™ Dissection Cannula, K981700, cleared on February 18, 1998. The design of the 7 mm Extended Length Endoscope with Dissection Tip is identical to the current E…
Origin Medsystems, Inc.1998—

Also cleared against K960637: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K1919307 mm Extended Length EndoscopeMaquet Cardiovascular, LLC20200

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 3.6 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K191930 (Maquet Cardiovascular, LLC, 2020) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K960637.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The 7 mm Extended Length Endoscope is indicated for visualization of a surgical cavity and dissection in endoscopic procedures and other minimally invasive surgical procedures allowing access for vessel harvesting, and is primarily indicated for patients undergoing endoscopic vessel harvesting for arterial bypass. It is indicated for patients requiring endoscopic tissue separation/vessel harvesting of the extraperitoneal or subcutaneous extremity and…

Read the full statement (99 words)

The 7 mm Extended Length Endoscope is indicated for visualization of a surgical cavity

and dissection in endoscopic procedures and other minimally invasive surgical

procedures allowing access for vessel harvesting, and is primarily indicated for patients

undergoing endoscopic vessel harvesting for arterial bypass. It is indicated for patients

requiring endoscopic tissue separation/vessel harvesting of the extraperitoneal or

subcutaneous extremity and thoracic space. Extremity procedures include tissue

dissection along the saphenous vein and the femoral vessels. Thoracoscopic procedures

include exposure and dissection of structures external to the parietal pleura, including

nerves, blood vessels and other tissues of the chest wall.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K014250: 7MM Extended Length Endoscope,Dissection Tips, Models VH-1111, VH-1114.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K014250

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026