510(k) · Cleared
Recalled · Class III · 2011G7 Automated HPLC Analyzer, Beta-Thalassemia Mode
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Tosoh Medics, Inc. · JPD Hemoglobin A2 Quantitation
Cleared on May 14, 2002 as substantially equivalent to K823870 (Helena Laboratories, 1983) and 2 other predicates after a 90-day review. Its family tree reaches back 1 generation to 1980. It has been recalled 2 times.
- Decided
- May 14, 2002
- Review
- 90 days
- Class
- Class II
- Product code
- JPD
- Recalls
- 2
- Predicates
- 3
Its longest line of descent runs back 1 generation to K802821 (1980). 3 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK802821 Paragon Hemoglobin Electro. Reag. KitBeckman Instruments, Inc. · 1980
- This deviceK020489 G7 Automated HPLC Analyzer, Beta-Thalassemia ModeTosoh Medics, Inc. · 2002
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K802821 | Paragon Hemoglobin Electro. Reag. Kit | Beckman Instruments, Inc. | 1980 | — |
| 0 (this device) | K020489 | G7 Automated HPLC Analyzer, Beta-Thalassemia Mode | Tosoh Medics, Inc. | 2002 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
| 1993 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JPD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K823870 | Beta Thalquik Column #5341Summary page 1…ated HPLC Analyzer: Beta- thalassemia Mode Class Il, JPD 21 CFR 864.7400 Hemoglobin A2 quantitation HbA2: Beta-Thal HbA2 Quik Column™ Helena Laboratories Beaumont, TX K823870 HbF: VARIANT BETA-THALASSEMIA SHORT PROGRAM Bio-Rad Laboratories Hercules, CA K924122 Presumptive Hb identification: Beckma… | 1983 |
| * | K924122 | Variant Beta-Thalassemia Short ProgramSummary page 1…antitation HbA2: Beta-Thal HbA2 Quik Column™ Helena Laboratories Beaumont, TX K823870 HbF: VARIANT BETA-THALASSEMIA SHORT PROGRAM Bio-Rad Laboratories Hercules, CA K924122 Presumptive Hb identification: Beckman Paragon® Electrophoresis Beckman Instruments, Inc. Fullerton, CA K802821 0110 347 Oys… | 1993 |
| * | K802821 | Paragon Hemoglobin Electro. Reag. KitSummary page 1…MIA SHORT PROGRAM Bio-Rad Laboratories Hercules, CA K924122 Presumptive Hb identification: Beckman Paragon® Electrophoresis Beckman Instruments, Inc. Fullerton, CA K802821 0110 347 Oyster Point Blvd., Suite 201, South San Francisco, California 94080 Tel: 650/615-4970 Toll Free: 1-800/248-6764 Fax:… | 1980 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 25, 2011 | Not classified | Z-3030-2011 | Process control | The value after reconstitution appeared to be lower than the assigned value on the label. The measured value for Lot BCAL05R was 5.3%, whereas the value on the label is 5.7%. The criteria of the value is +/- 0.3%. |
| Aug 18, 2010 | Class III | Z-1075-2013 | Component change control | The Beta-thalessemia Mode of the G7 Analyzer-Beta Thalassemia Mode is an automated High Performance Liquid Chromatography (HPLC) system that separates and reports HbF and HbA2 quantitative percentages in whole blood. The firm received… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- 1 of the 3 ancestors has a recall of any class.
How does its category compare?
All JPD devicesJPD Hemoglobin A2 Quantitation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JPD
FDA has decided no JPD device since 2007.
Median 510(k) review, days · JPD
Too few JPD 510(k)s in any year since 2007 to give a median.
Recalls per year · JPD
1in 2011
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JPD
No MAUDE report names JPD since 2007.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 2 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 1 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The G7 Automated HPLC Analyzer: Beta-thalassemia Mode is intended for IN VITRO DIAGNOSTIC USE ONLY for the separation and area percent determinations of hemoglobins A2 and F and as an aid in the detection and presumptive identification of abnormal hemoglobins in whole biood using ion-exchange high performance liquid chromatography (HPLC).
The G7 Automated HPLC Analyzer: Beta-thalassemia Mode reagents and software are intended only for use on the Tosoh G7 Automated HPLC Analyzer.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K020489 · printed Nov 6, 2026
Cite this page
510(k) Report. “K020489: G7 Automated HPLC Analyzer, Beta-Thalassemia Mode.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020489
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026