510(k) Report

510(k) · Cleared

Recalled · Class II · 2015

Synthes Dual-Opening Uss

K020517510(k) SpecialCleared Apr 15, 200255-day reviewClass II21 CFR 888.3070Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Synthes (Usa) · MNI Orthosis, Spinal Pedicle Fixation

Cleared on Apr 15, 2002 after a 55-day review. The FDA summary names no predicate by number. It has been recalled 3 times.

Decided
Apr 15, 2002
Review
55 days
Class
Class II
Product code
MNI
Recalls
3
Predicates
0

The FDA summary names no predicate by number.

FIG. 1 — Lineage of K020517Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MNI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 4, 2015Class IIZ-0134-2016Process controlThis product was produced using a finishing process not identified as part of the manufacturing specification. The process used with the lots subject to this Recall was a bead blast process. (Bead Blasting vs. Shot Peened).
Jun 5, 2013Class IIZ-1935-2013Nonconforming Material/ComponentDePuy Synthes has issued a Medical Device Correction notice for the 5.0mm Stainless Steel rods. This product was produced using a finishing process not identified as part of the manufacturing specification. No adverse event reports…
May 31, 2012Class IIZ-2054-2012Employee errorUSS Lamina Hooks, Medium, Right are being recalled because the hooks are etched with the wrong part number - 498.321 (Lamina Hook, Medium, Left). The Lamina Hooks should be etched with part number 498.320 (Lamina Hook, Medium, right).

No ancestor or descendant has a Class I recall.

How does its category compare?

All MNI devices

MNI Orthosis, Spinal Pedicle Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MNI

1in 2017

2007: 202008: 232009: 182010: 162011: 172012: 192013: 142014: 62015: 122016: 72017: 1
2007high 23 (2008) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNI

168in 2016

2007: 82 days median2008: 64 days median2009: 86 days median2010: 74 days median2011: 111 days median2012: 75 days median2013: 77 days median2014: 104 days median2015: 54 days median2016: 168 days median
2007high 168 (2016) · low 54 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MNI

1in 2018

2007: 262008: 82009: 32010: 12012: 12013: 42015: 12018: 1
2007high 26 (2007) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MNI

80in 2025

2007: 832008: 1082009: 1382010: 1262011: 1462012: 2002013: 8242014: 3012015: 2602016: 1172017: 2472018: 1342019: 1882020: 1152021: 2702022: 2142023: 1222024: 1142025: 80
2007high 824 (2013) · low 80 (2025)2025

MAUDE reports naming product code MNI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200720822683
200823648108
200918863138
201016741126
2011171110146
201219751200
201314774824
201461040301
201512541260
201671680117
20171—0247
20180—1134
20190—0188
20200—0115
20210—0270
20220—0214
20230—0122
20240—0114
20250—080
20260—0—

What is it indicated for?

When used as a posterior pedicle screw fixation system, the Synthes Small Stature USS and the Dual-Opening USS are intended to provide immobilization and stabilization of spinal segments in skeletally mature patients (including small statue) as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic…

Read the full statement (313 words)

When used as a posterior pedicle screw fixation system, the Synthes Small Stature USS and the Dual-Opening USS are intended to provide immobilization and stabilization of spinal segments in skeletally mature patients (including small statue) as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis).

In addition, the Synthes Small Stature USS and the Dual-Opening USS are intended for treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients (including small stature) and pediatric patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation for these patients are L3-S2.

When used as a posterior non-pedicle screw fixation system in skeletally mature patients (including small stature) and pediatric patients, the Synthes Small Stature USS and the Dual-Opening USS are intended for scoliosis, Schuermann’s disease, degenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), and fractures of the posterior thoracolumbar spine.

The anterior components of the Synthes Small Stature USS and the Dual-Opening USS when used in skeletally mature patients (including small stature) and pediatric patients are intended for anterolateral screw and/or staple fixation for the correction of anterolateral lordotic deformities for the spine, lumbar scoliosis, pseudoarthrosis, and fracture or dislocation of the thoracolumbar spine (levels T8-L5).

In addition, when used with 3.5/5.0 mm parallel connectors, the Synthes Small Stature USS can be linked to the CerviFix™ System. When used with 5.0/6.0 mm parallel connectors, the Synthes Small Stature USS can be linked to the Universal Spinal System and the Dual-Opening USS.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020517: Synthes Dual-Opening Uss.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K020517

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)