Cleared on Apr 25, 2002 as substantially equivalent to K895520 (Hewlett-Packard Co., 1990) after a 51-day review. Its family tree reaches back 1 generation to 1990. 47 later devices descend from it. It has been recalled 2 times.
- Decided
- Apr 25, 2002
- Review
- 51 days
- Class
- Class II
- Product code
- DPS
- Recalls
- 2
- Predicates
- 1
Its longest line of descent runs back 1 generation to K895520 (1990). 47 later devices descend from it, 6 citing it directly.
- Root · 1 generation backK895520 Pagewriter Xli M1700A & Pagewriter XL M1701AHewlett-Packard Co. · 1990
- This deviceK020708 Philips Pagewriter Touch Cardiograph, Model M5000A SeriesPhilips Medical Systems, Inc. · 2002
- Descendant · cites it directly · 27 of its ownK031422 Philips Page Writer Trim Series Cardiograph Including I, II, Iii…Philips Medical Systems · 2003
- Descendant · 2 generations on · 12 of its ownK050074 12-Lead Resting Electrocardiograph, Models CP100 & CP200Welch Allyn, Inc. · 2005
- Descendant · 2 generations on · 11 of its ownK060167 Atria 3100, Atria 6100Cardiac Science Corporation · 2006
- Descendant · 3 generations on · 8 of its ownK160876 PC ECGEdan Instruments, Inc. · 2017
- Descendant · cites it directly · 7 of its ownK080999 Pagewriter CardiographPhilips Medical Systems · 2008
Showing 5 of 47 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 47 · See all- K031422Philips Page Writer Trim Series Cardiograph Including I, II, Iii, Models 860286, 860287…Philips Medical Systems · 2003 · cites it directly27descendants
- K05007412-Lead Resting Electrocardiograph, Models CP100 & CP200Welch Allyn, Inc. · 2005 · 2 generations on12descendants
- K060167Atria 3100, Atria 6100Cardiac Science Corporation · 2006 · 2 generations on11descendants
- K160876PC ECGEdan Instruments, Inc. · 2017 · 3 generations on8descendants
- K080999Pagewriter CardiographPhilips Medical Systems · 2008 · cites it directly7descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K895520 | Pagewriter Xli M1700A & Pagewriter XL M1701A | Hewlett-Packard Co. | 1990 | — |
| 0 (this device) | K020708 | Philips Pagewriter Touch Cardiograph, Model M5000A Series | Philips Medical Systems, Inc. | 2002 | — |
| +1 | K031422 | Philips Page Writer Trim Series Cardiograph Including I, II, Iii, Models… | Philips Medical Systems | 2003 | — |
| +2 | K050074 | 12-Lead Resting Electrocardiograph, Models CP100 & CP200 | Welch Allyn, Inc. | 2005 | — |
| +2 | K060167 | Atria 3100, Atria 6100 | Cardiac Science Corporation | 2006 | — |
| +3 | K160876 | PC ECG | Edan Instruments, Inc. | 2017 | — |
| +1 | K080999 | Pagewriter Cardiograph | Philips Medical Systems | 2008 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2005 | 3 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 2 | 0 |
| 2009 | 2 | 0 |
| 2010 | 2 | 0 |
| 2011 | 2 | 0 |
| 2012 | 2 | 0 |
| 2013 | 3 | 0 |
| 2014 | 1 | 0 |
| 2015 | 3 | 0 |
| 2016 | 3 | 0 |
| 2017 | 4 | 0 |
| 2018 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 3 | 0 |
| 2022 | 5 | 0 |
| 2023 | 3 | 0 |
| 2024 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DPS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DPS device
- #1 K212112 Cardiologs Holter Platformscore 18.6 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K895520 | Pagewriter Xli M1700A & Pagewriter XL M1701ASummary page 1…s to which equivalence is being claimed is the M1700A Cardiograph manufactured by Philips Medical ‘Systems (formerly Healthcare Solutions Group of Hewlett-Packard Co.) — K895520 6. DEVICE DESCRIPTION The M5000A Series Cardiograph is Philips Medical Systems’ cardiograph offering a full complement of featu… | 1990 |
What descends from it? (47)
See all 476 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K031422 | Philips Page Writer Trim Series Cardiograph Including I, II, Iii, Models 860286, 860287… | 2003 | 27 |
| K080999 | Pagewriter Cardiograph | 2008 | 7 |
| K052049 | Philips 12-Lead Algorithm | 2005 | 7 |
| K073376 | Philips Ecg Algorithm | 2008 | 5 |
| K123130 | Answatch Wrist Monitor Model TS-0411 | 2013 | 2 |
| K132068 | Philips DXL 12/16-Lead Ecg Algorithm | 2013 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 12, 2007 | Not classified | Z-0124-2008 | Software change control | Incorrect display: When using the 16 lead Patient Interface Module (PIM), lead tracings of V3R and V4R are reversed in the extended lead modes of Pediatric and Balanced. |
| Oct 13, 2004 | Not classified | Z-0063-05 | Other | Software can generate printed ECG's that associate incorrect patient data with the waveform |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All DPS devicesDPS Electrocardiograph: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DPS
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DPS
163in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DPS
3in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · DPS
55in 2025
MAUDE reports naming product code DPS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 11 | 87 | 2 | 9 |
| 2008 | 13 | 31 | 0 | 17 |
| 2009 | 14 | 84 | 1 | 14 |
| 2010 | 11 | 104 | 2 | 21 |
| 2011 | 22 | 154 | 1 | 121 |
| 2012 | 12 | 117 | 0 | 56 |
| 2013 | 10 | 134 | 0 | 15 |
| 2014 | 11 | 253 | 0 | 15 |
| 2015 | 8 | 178 | 0 | 30 |
| 2016 | 11 | 229 | 0 | 12 |
| 2017 | 9 | 177 | 0 | 15 |
| 2018 | 14 | 221 | 0 | 19 |
| 2019 | 3 | 178 | 9 | 27 |
| 2020 | 6 | 224 | 2 | 59 |
| 2021 | 5 | 135 | 1 | 24 |
| 2022 | 6 | 244 | 1 | 59 |
| 2023 | 10 | 236 | 3 | 54 |
| 2024 | 8 | 260 | 4 (1) | 64 |
| 2025 | 6 | 163 | 3 | 55 |
| 2026 | 6 | 258 | 4 | — |
What is it indicated for?
Where the clinician decides to evaluate the electrocardiogram of adult and pediatric patients as part of decisions regarding possible diagnosis, potential treatment, effectiveness of treatment or to rule-out causes for symptoms.
Where the clinician decides to evaluate the electrocardiogram of adult and pediatric patients as part of decisions regarding possible diagnosis, potential treatment, effectiveness of treatment or to rule-out causes for symptoms.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K020708 · printed Nov 6, 2026
Cite this page
510(k) Report. “K020708: Philips Pagewriter Touch Cardiograph, Model M5000A Series.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020708
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026