510(k) · Cleared
ClearedPVS 1500 SDS
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Precision Vascular Systems, Inc. · KRA Catheter, Continuous Flush
Cleared on Mar 21, 2002 as substantially equivalent to K960806 (Target Therapeutics, 1996) and 1 other predicate after a 15-day review. Its family tree reaches back 1 generation to 1996. 21 later devices descend from it.
- Decided
- Mar 21, 2002
- Review
- 15 days
- Class
- Class II
- Product code
- KRA
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K960806 (1996). 2 ancestors in all. 21 later devices descend from it, 3 citing it directly.
- Root · 1 generation backK960806 Turbo TrackerTarget Therapeutics · 1996
- This deviceK020733 PVS 1500 SDSPrecision Vascular Systems, Inc. · 2002
- Descendant · cites it directly · 20 of its ownK032494 PVS 1700 Steerable Delivery System MicrocatheterPrecision Vascular Systems, Inc. · 2003
- Descendant · 2 generations on · 17 of its ownK041123 Rinspiration System,Rinspiration System Short Tip, Models…Kerberos Proximal Solutions, Inc. · 2004
- Descendant · 3 generations on · 16 of its ownK050130 Kerberos Proximal Solutions Rispiration SystemKerberos Proximal Solutions, Inc. · 2005
- Descendant · 4 generations on · 9 of its ownK062275 Rinspiration Catheter System, Models 50135, 550135, P7065, P70135Kerberos Proximal Solutions, Inc. · 2006
- Descendant · 4 generations on · 6 of its ownK080901 Lbi Embolectomy SystemLumen Biomedical, Inc. · 2008
Showing 5 of 21 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 21 · See all- K032494PVS 1700 Steerable Delivery System MicrocatheterPrecision Vascular Systems, Inc. · 2003 · cites it directly20descendants
- K041123Rinspiration System,Rinspiration System Short Tip, Models FG01477/FG01703Kerberos Proximal Solutions, Inc. · 2004 · 2 generations on17descendants
- K050130Kerberos Proximal Solutions Rispiration SystemKerberos Proximal Solutions, Inc. · 2005 · 3 generations on16descendants
- K062275Rinspiration Catheter System, Models 50135, 550135, P7065, P70135Kerberos Proximal Solutions, Inc. · 2006 · 4 generations on9descendants
- K080901Lbi Embolectomy SystemLumen Biomedical, Inc. · 2008 · 4 generations on6descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K960806 | Turbo Tracker | Target Therapeutics | 1996 | — |
| 0 (this device) | K020733 | PVS 1500 SDS | Precision Vascular Systems, Inc. | 2002 | — |
| +1 | K032494 | PVS 1700 Steerable Delivery System Microcatheter | Precision Vascular Systems, Inc. | 2003 | — |
| +2 | K041123 | Rinspiration System,Rinspiration System Short Tip, Models FG01477/FG01703 | Kerberos Proximal Solutions, Inc. | 2004 | — |
| +3 | K050130 | Kerberos Proximal Solutions Rispiration System | Kerberos Proximal Solutions, Inc. | 2005 | — |
| +4 | K062275 | Rinspiration Catheter System, Models 50135, 550135, P7065, P70135 | Kerberos Proximal Solutions, Inc. | 2006 | — |
| +4 | K080901 | Lbi Embolectomy System | Lumen Biomedical, Inc. | 2008 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 2 | 0 |
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 2 | 0 |
| 2012 | 2 | 0 |
| 2014 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 2 | 0 |
| 2023 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KRA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KRA device
- #1 K253509 TriSalus TriNav Advance Infusion Systemscore 14.5 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K960806 | Turbo TrackerSummary page 1…The predicate devices are listed in the table below. . : 510(k) ‘Number, Product Pl;g‘c:;g:;e Device Manufacturer Concurence Date Code FasTracker-18 Target Therapeutics K960806, 02 May 1996* DQO Rebar-18 Micro Therapeutics K0019686, 20 Jui 2000 KRA * This information is assumed based on our best, current… | 1996 |
| * | K001966 | Rebar Micro Catheter: Rebar-18 [2.3F], 110 CM, 130 CM, 153 CM, Single Marker Band and… Our OCR of the scanned summary read K001968, which is not a number in FDA’s lists. Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Rebar-18”. | 2000 |
What descends from it? (21)
See all 213 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All KRA devicesKRA Catheter, Continuous Flush: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KRA
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KRA
63in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KRA
41so far in 2026, the most since 2007
Class I (7 since 2007) Class II/III not classified
Adverse event reports per year · KRA
980in 2025
MAUDE reports naming product code KRA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 44 | 2 | 118 |
| 2008 | 7 | 144 | 6 | 117 |
| 2009 | 5 | 69 | 8 | 187 |
| 2010 | 2 | — | 26 | 355 |
| 2011 | 2 | — | 3 | 239 |
| 2012 | 3 | 29 | 3 | 217 |
| 2013 | 3 | 126 | 2 | 209 |
| 2014 | 4 | 61 | 3 (2) | 276 |
| 2015 | 0 | — | 1 | 339 |
| 2016 | 8 | 122 | 3 (1) | 418 |
| 2017 | 4 | 166 | 0 | 538 |
| 2018 | 4 | 178 | 0 | 434 |
| 2019 | 4 | 133 | 4 (4) | 418 |
| 2020 | 6 | 29 | 1 | 381 |
| 2021 | 6 | 108 | 0 | 440 |
| 2022 | 6 | 228 | 0 | 543 |
| 2023 | 7 | 63 | 2 | 829 |
| 2024 | 0 | — | 0 | 942 |
| 2025 | 1 | — | 0 | 980 |
| 2026 | 5 | 268 | 41 | — |
What is it indicated for?
The PVS 1500 SDS is intended for use in accessing distal peripheral, coronary, and neurovasculature for the sub-selective, controlled, regional delivery of diagnostic, embolic, and therapeutic agents into selected vessels.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K020733 · printed Nov 4, 2026
Cite this page
510(k) Report. “K020733: PVS 1500 SDS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K020733
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026