510(k) Report

510(k) · Cleared

Cleared

Goldway Digital Video Colposcope Imaging System, Model #SLC-2000

K021153510(k) TraditionalCleared Feb 10, 2003306-day reviewClass II21 CFR 884.1630

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Goldway Us, Inc. · HEX Colposcope (And Colpomicroscope)

Cleared on Feb 10, 2003 as substantially equivalent to K000707 (Leica Microscopy Systems, Ltd., 2000) and 2 other predicates after a 306-day review. Its family tree reaches back 1 generation to 1995. 13 later devices descend from it.

Decided
Feb 10, 2003
Review
306 days
Class
Class II
Product code
HEX
Recalls
None
Predicates
3

Its longest line of descent runs back 1 generation to K940094 (1995). 3 ancestors in all. 13 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor1996: 1 other ancestor2011: 1 descendant cleared2016: 2 descendants cleared2013: 2 descendants cleared2015: 1 descendant cleared2018: 2 descendants cleared2014: 2 descendants cleared2019: 1 descendant cleared2021: 1 descendant cleared2024: 1 descendant clearedK940094 · Colposcopes and Accessories · Leisegang Medical, Inc. · 19951995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 5 descendants2 generations forward: 6 descendants3 generations forward: 2 descendants K940094 · Colposcopes and Accessories · Leisegang Medical, Inc. · 19950
  1. Root · 1 generation backK940094 Colposcopes and AccessoriesLeisegang Medical, Inc. · 1995
  2. This deviceK021153 Goldway Digital Video Colposcope Imaging System, Model #SLC-2000Goldway Us, Inc. · 2003
  3. Descendant · cites it directly · 7 of its ownK122973 AL-106, AL-106SA and AL-106B Medgyn Digital Video ColposcopeMedgyn Products, Inc. · 2013
  4. Descendant · cites it directly · 2 of its ownK151878 Video ColposcopeEdan Instruments, Inc. · 2015
  5. Descendant · 2 generations on · 1 of its ownK181034 Pocket Colposcope SystemHadleigh Health Technologies, LLC · 2018
  6. Descendant · 2 generations on · 1 of its ownK161871 EVA (Enhanced Visual Assessment) SystemMobileodt, Ltd. · 2016
  7. Descendant · 2 generations on · 1 of its ownK140754 Cooper Surgical Leisegang Colposcope SystemCooperSurgical, Inc. · 2014

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2011: 12013: 22014: 22015: 12016: 22018: 22019: 12021: 12024: 1
2011high 2 (2013) · low 0 (2012)2026

Most influential descendants

Showing 5 of 13 · See all
  • K122973AL-106, AL-106SA and AL-106B Medgyn Digital Video ColposcopeMedgyn Products, Inc. · 2013 · cites it directly7descendants
  • K151878Video ColposcopeEdan Instruments, Inc. · 2015 · cites it directly2descendants
  • K181034Pocket Colposcope SystemHadleigh Health Technologies, LLC · 2018 · 2 generations on1descendant
  • K161871EVA (Enhanced Visual Assessment) SystemMobileodt, Ltd. · 2016 · 2 generations on1descendant
  • K140754Cooper Surgical Leisegang Colposcope SystemCooperSurgical, Inc. · 2014 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K940094Colposcopes and AccessoriesLeisegang Medical, Inc.1995—
0 (this device)K021153Goldway Digital Video Colposcope Imaging System, Model #SLC-2000Goldway Us, Inc.2003—
+1K122973AL-106, AL-106SA and AL-106B Medgyn Digital Video ColposcopeMedgyn Products, Inc.2013—
+1K151878Video ColposcopeEdan Instruments, Inc.2015—
+2K181034Pocket Colposcope SystemHadleigh Health Technologies, LLC2018—
+2K161871EVA (Enhanced Visual Assessment) SystemMobileodt, Ltd.2016—
+2K140754Cooper Surgical Leisegang Colposcope SystemCooperSurgical, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201320
201420
201510
201620
201820
201910
202110
202410
FIG. 1 — Lineage of K021153, 1995–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HEX device

  1. #1 K233043 Smart Scope® CXscore 8.4 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K000707Leica Colposcope
Summary page 2
…icate Device Information Identification of Legally Markted Device Which We Claim Substantial Equivalence (Predicate Device): 1. Leica Colposcopes, MS-5 and MZ-6, K#000707, Leica Microscopy Systems Ltd., Depew, New York. 2. Leisegang Video Colposcope (LMZ), K#940094, Leisegang Medical, Inc…
Leica Microscopy Systems, Ltd.2000—
*K940094Colposcopes and Accessories
Summary page 2
…(Predicate Device): 1. Leica Colposcopes, MS-5 and MZ-6, K#000707, Leica Microscopy Systems Ltd., Depew, New York. 2. Leisegang Video Colposcope (LMZ), K#940094, Leisegang Medical, Inc., Boca Raton, Florida 3. Welch Allyn Video Colposcope, 88000 and 89000, K#955635, Welch Allyn,…
Leisegang Medical, Inc.1995—
*K955635Video Colposcope/Vertical Rolling Base/Swing Arm Stand
Summary page 2
…New York. 2. Leisegang Video Colposcope (LMZ), K#940094, Leisegang Medical, Inc., Boca Raton, Florida 3. Welch Allyn Video Colposcope, 88000 and 89000, K#955635, Welch Allyn, Inc. 10-2 4. Device…
Welch Allyn, Inc.1996—

Also cleared against K000707: 1 other device →

What descends from it? (13)

See all 13

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K122973AL-106, AL-106SA and AL-106B Medgyn Digital Video ColposcopeMedgyn Products, Inc.20137
K151878Video ColposcopeEdan Instruments, Inc.20152
K160341Colposcope SystemXuzhou Kernel Medical Equipment Co., Ltd.20160
K122311GC-3000E Digital ColposcopeShenzhen Goldcare Meditech Co., Ltd.20130
K092433DYSISForth Photonics Hellas SA20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 3 ancestors has a recall.
  • Of its descendants, K122973 (Medgyn Products, Inc., 2013) has gone furthest, with 7 descendants of its own.
  • 1 other device also cites its predicate K000707.

How does its category compare?

All HEX devices

HEX Colposcope (And Colpomicroscope): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HEX

1in 2024

2007: 22008: 12010: 32011: 22013: 22014: 32015: 12016: 32017: 12018: 22019: 12024: 1
2007high 3 (2010) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HEX

165in 2016

2010: 129 days median2014: 211 days median2016: 165 days median
2007high 211 (2014) · low 129 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HEX

No recall names HEX since 2007.

Adverse event reports per year · HEX

1in 2025

2008: 22011: 12014: 22019: 22020: 12021: 12024: 12025: 1
2007high 2 (2008) · low 0 (2007)2025

MAUDE reports naming product code HEX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—02
20090—00
2010312900
20112—01
20120—00
20132—00
2014321102
20151—00
2016316500
20171—00
20182—00
20191—02
20200—01
20210—01
20220—00
20230—00
20241—01
20250—01
20260—0—

What is it indicated for?

The Goldway Digital Video Colposcope Imaging System is intended for magnified viewing of the vagina, cervix and external genitalia in order to diagnose abnormalities and select areas for biopsy. The imag,e system is intended to provide documentation of the image in the field of view of the colposcope. The image can be viewed on a color screen, printed on a color printer or archived for storage and subsequent retrieval. The device is intended for use in Hospitals and clinics.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K021153: Goldway Digital Video Colposcope Imaging System, Model #SLC-2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K021153

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026