510(k) Report

510(k) · Cleared

Recalled · Class II · 2015

ORS-1000LD

K021288510(k) TraditionalCleared Jun 27, 200265-day reviewClass I21 CFR 890.5950Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

O.R. Solutions, Inc. · LHC Warmer, Irrigation Solution

Cleared on Jun 27, 2002 after a 65-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 later devices descend from it. It has been recalled once.

Decided
Jun 27, 2002
Review
65 days
Class
Class I
Product code
LHC
Recalls
1
Predicates
0

3 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2014: 2 descendants cleared2016: 1 descendant cleared200020052010201520202025
  1. This deviceK021288 ORS-1000LDO.R. Solutions, Inc. · 2002
  2. Descendant · cites it directly · 0 of its ownK152522 ORS-3000LD Slush Drapes, ORS-1000LD Fluid Warming DrapesEcolab, Inc. · 2016
  3. Descendant · cites it directly · 0 of its ownK142173 Non-Sterile Ors-400N Scope Pillow Warmer DrapeEcolab, Inc. · 2014
  4. Descendant · cites it directly · 0 of its ownK142080 Non-Sterile Ors Warning Drapes/Slush+Warmer Disc-Drape/Slush+Warmer…Ecolab, Inc. · 2014 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K152522ORS-3000LD Slush Drapes, ORS-1000LD Fluid Warming DrapesEcolab, Inc. · 2016 · cites it directly0descendants
  • K142173Non-Sterile Ors-400N Scope Pillow Warmer DrapeEcolab, Inc. · 2014 · cites it directly0descendants
  • K142080Non-Sterile Ors Warning Drapes/Slush+Warmer Disc-Drape/Slush+Warmer Palte-Drape /Fluid…Ecolab, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K021288ORS-1000LDO.R. Solutions, Inc.2002—
+1K152522ORS-3000LD Slush Drapes, ORS-1000LD Fluid Warming DrapesEcolab, Inc.2016—
+1K142173Non-Sterile Ors-400N Scope Pillow Warmer DrapeEcolab, Inc.2014—
+1K142080Non-Sterile Ors Warning Drapes/Slush+Warmer Disc-Drape/Slush+Warmer…Ecolab, Inc.20149

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201420
201610
FIG. 1 — Lineage of K021288, 2002–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LHC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152522ORS-3000LD Slush Drapes, ORS-1000LD Fluid Warming DrapesEcolab, Inc.20160
K142173Non-Sterile Ors-400N Scope Pillow Warmer DrapeEcolab, Inc.20140
K142080Non-Sterile Ors Warning Drapes/Slush+Warmer Disc-Drape/Slush+Warmer Palte-Drape /Fluid…Ecolab, Inc.20140

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 18, 2015Class IIZ-2793-2015Package design/selectionThe sterile packaging may contain small (less than 250 microns wide) channels in the seal of the pouch. If channels are present, the package integrity is compromised and there is a remote chance that a non-sterile drape may be used during…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K152522 (Ecolab, Inc., 2016) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LHC devices

LHC Warmer, Irrigation Solution: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LHC

2in 2016

2008: 12009: 12014: 22015: 12016: 2
2007high 2 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LHC

Too few LHC 510(k)s in any year since 2007 to give a median.

Recalls per year · LHC

8in 2015

2015: 8
2007high 8 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LHC

6in 2025

2007: 32008: 52009: 22010: 12011: 22012: 52013: 22014: 42015: 132016: 692017: 332018: 302019: 82020: 42021: 52022: 12024: 52025: 6
2007high 69 (2016) · low 0 (2023)2025

MAUDE reports naming product code LHC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20081—05
20091—02
20100—01
20110—02
20120—05
20130—02
20142—04
20151—813
20162—069
20170—033
20180—030
20190—08
20200—04
20210—05
20220—01
20230—00
20240—05
20250—06
20260—0—

What is it indicated for?

The ORS-1000LD Leak Detection Drape is an equipment cover for the ORS-2000LD Solution Warmer. This is a single use product supplied sterile. This device is intended for use during various surgeries where warm irrigation solution is required.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K021288: ORS-1000LD.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K021288

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026