510(k) · Cleared
ClearedPMX Compact Resucitator
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cheen Houng Ent. Co., Ltd. · BTM Ventilator, Emergency, Manual (Resuscitator)
Cleared on Oct 4, 2002 after a 155-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Oct 4, 2002
- Review
- 155 days
- Class
- Class II
- Product code
- BTM
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in BTM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new BTM device
- #1 K243861 butterflyBVMscore 9.5 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All BTM devicesBTM Ventilator, Emergency, Manual (Resuscitator): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · BTM
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · BTM
83in 2008
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · BTM
9in 2024
Class I (24 since 2007) Class II/III not classified
Adverse event reports per year · BTM
36in 2025
MAUDE reports naming product code BTM, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 65 |
| 2008 | 3 | 83 | 0 | 31 |
| 2009 | 0 | — | 23 | 21 |
| 2010 | 2 | — | 3 | 23 |
| 2011 | 2 | — | 0 | 48 |
| 2012 | 1 | — | 13 (13) | 69 |
| 2013 | 0 | — | 3 (1) | 44 |
| 2014 | 0 | — | 0 | 108 |
| 2015 | 1 | — | 0 | 36 |
| 2016 | 1 | — | 0 | 92 |
| 2017 | 0 | — | 0 | 56 |
| 2018 | 2 | — | 0 | 56 |
| 2019 | 0 | — | 0 | 46 |
| 2020 | 0 | — | 0 | 26 |
| 2021 | 1 | — | 0 | 42 |
| 2022 | 1 | — | 0 | 35 |
| 2023 | 1 | — | 9 | 46 |
| 2024 | 0 | — | 9 (9) | 33 |
| 2025 | 2 | — | 0 | 36 |
| 2026 | 1 | — | 1 (1) | — |
What is it indicated for?
The PMX COMPACT RESUSCITATOR are manual resuscitators incorporating a bag and valve, intended to provide emergency ventilation or ventilation during patient transport. The infant model is intended for patients weighing between 5 to 12 kgs, the child model is intended for patients weighing between 10 to 30 kgs, and the adult model is intended for patients weighing more than 30 kgs approximate weight. The PMX COMPACT RESUSCITATOR provided in reusable models and in the disposable models.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K021390 · printed Nov 4, 2026
Cite this page
510(k) Report. “K021390: PMX Compact Resucitator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021390
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026