510(k) · Cleared
ClearedV.a.C. Instillamat (Vacuum Assisted Closure Instillamat
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Kinetic Concepts, Inc. · OMP Negative Pressure Wound Therapy Powered Suction Pump
Cleared on Dec 2, 2002 as substantially equivalent to K992448 (Kinetic Concepts, Inc., 2000) and 1 other predicate after a 207-day review. Its family tree reaches back 2 generations to 1995. 30 later devices descend from it.
- Decided
- Dec 2, 2002
- Review
- 207 days
- Class
- Class II
- Product code
- OMP
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K945062 (1995). 3 ancestors in all. 30 later devices descend from it, 4 citing it directly.
- Root · 2 generations backK945062 VacplusKinetic Concepts, Inc. · 1995
- 1 generation backK971548 AmbuvacKinetic Concepts, Inc. · 1997
- This deviceK021501 V.a.C. Instillamat (Vacuum Assisted Closure InstillamatKinetic Concepts, Inc. · 2002
- Descendant · cites it directly · 19 of its ownK100657 V.a.C. Ulta Negative Pressure Wound Therapy System (V.a.C. Ulta…Kci USA, Inc. (Kinetic Concepts, Inc.) · 2010
- Descendant · 2 generations on · 10 of its ownK141017 Prevena Incision Management System with Peel & Dressing, Prevena…Kci USA, Inc. (Kinetic Concepts, Inc.) · 2015
- Descendant · 3 generations on · 9 of its ownK153199 Prevena Plus Incision Management System Kit with Peel & Place…Kci USA, Inc. · 2016
- Descendant · 3 generations on · 8 of its ownK161897 PREVENA DUO, PREVENA PLUS DUO Incision Management Systems with PEEL…Kci USA, Inc. (Kinetic Concepts, Inc.) · 2016
- Descendant · 4 generations on · 7 of its ownK173426 PREVENA PLUS Incision Management System, PREVENA PLUS DUO Incision…Kci USA, Inc. · 2018
Showing 5 of 30 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 30 · See all- K100657V.a.C. Ulta Negative Pressure Wound Therapy System (V.a.C. Ulta Therapy System) Model…Kci USA, Inc. (Kinetic Concepts, Inc.) · 2010 · cites it directly19descendants
- K141017Prevena Incision Management System with Peel & Dressing, Prevena Incision Management…Kci USA, Inc. (Kinetic Concepts, Inc.) · 2015 · 2 generations on10descendants
- K153199Prevena Plus Incision Management System Kit with Peel & Place Dressing, Prevena Plus…Kci USA, Inc. · 2016 · 3 generations on9descendants
- K161897PREVENA DUO, PREVENA PLUS DUO Incision Management Systems with PEEL & PLACE DressingsKci USA, Inc. (Kinetic Concepts, Inc.) · 2016 · 3 generations on8descendants
- K173426PREVENA PLUS Incision Management System, PREVENA PLUS DUO Incision Management SystemKci USA, Inc. · 2018 · 4 generations on7descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K945062 | Vacplus | Kinetic Concepts, Inc. | 1995 | — |
| −1 | K971548 | Ambuvac | Kinetic Concepts, Inc. | 1997 | — |
| 0 (this device) | K021501 | V.a.C. Instillamat (Vacuum Assisted Closure Instillamat | Kinetic Concepts, Inc. | 2002 | — |
| +1 | K100657 | V.a.C. Ulta Negative Pressure Wound Therapy System (V.a.C. Ulta Therapy… | Kci USA, Inc. (Kinetic Concepts, Inc.) | 2010 | — |
| +2 | K141017 | Prevena Incision Management System with Peel & Dressing, Prevena Incision… | Kci USA, Inc. (Kinetic Concepts, Inc.) | 2015 | — |
| +3 | K153199 | Prevena Plus Incision Management System Kit with Peel & Place Dressing… | Kci USA, Inc. | 2016 | — |
| +3 | K161897 | PREVENA DUO, PREVENA PLUS DUO Incision Management Systems with PEEL & PLACE… | Kci USA, Inc. (Kinetic Concepts, Inc.) | 2016 | — |
| +4 | K173426 | PREVENA PLUS Incision Management System, PREVENA PLUS DUO Incision Management… | Kci USA, Inc. | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 2 | 0 |
| 2007 | 1 | 0 |
| 2009 | 3 | 0 |
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 3 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 2 | 0 |
| 2020 | 1 | 0 |
| 2021 | 3 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OMP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OMP device
- #1 K260646 Renasys Edge (66803126)score 15.3 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K992448 | V.a.C. PlusSummary page 1…Contact: Judith Harbour 1-800-275-4524 IV. Substantial Equivalence: V.A.C. Plus 51O(k) No.K992448 Ambulatory V.A.C. 510(k) No.K971548 V, Description o f… | 2000 |
| * | K971548 | AmbuvacSummary page 1…V.A.C. Plus 51O(k) No.K992448 Ambulatory V.A.C. 510(k) No.K971548 V, Description o f Device The V.A.C. Instillamat device is a modified V.A.C. device manufactured by Kinetic Concepts… | 1997 |
What descends from it? (30)
See all 304 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 5.5 years on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K100657 (Kci USA, Inc. (Kinetic Concepts, Inc.), 2010) has gone furthest, with 19 descendants of its own.
- 4 other devices also cite its predicate K992448.
How does its category compare?
All OMP devicesOMP Negative Pressure Wound Therapy Powered Suction Pump: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · OMP
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OMP
127in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OMP
2in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OMP
140in 2025
MAUDE reports naming product code OMP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 113 | 0 | 1 |
| 2008 | 8 | 98 | 0 | 1 |
| 2009 | 8 | 87 | 7 | 79 |
| 2010 | 6 | 97 | 3 | 80 |
| 2011 | 6 | 123 | 0 | 130 |
| 2012 | 11 | 292 | 1 | 97 |
| 2013 | 11 | 84 | 2 | 169 |
| 2014 | 10 | 179 | 4 | 229 |
| 2015 | 20 | 189 | 1 | 378 |
| 2016 | 19 | 146 | 2 | 398 |
| 2017 | 11 | 137 | 0 | 368 |
| 2018 | 13 | 214 | 0 | 422 |
| 2019 | 15 | 249 | 1 | 994 |
| 2020 | 6 | 179 | 0 | 3,664 |
| 2021 | 9 | 238 | 0 | 1,422 |
| 2022 | 10 | 229 | 0 | 258 |
| 2023 | 8 | 291 | 0 | 143 |
| 2024 | 9 | 181 | 2 | 135 |
| 2025 | 5 | 127 | 0 | 140 |
| 2026 | 9 | 141 | 0 | — |
What is it indicated for?
The V.A.C. Instillamat device is indicated for patients who would benefit from
vacuum assisted drainage and controlled delivery of topical wound treatment
solutions and suspensions over the wound bed.
The V.A.C. is intended for patients with chronic, acute, traumatic, subacute and
dehisced wounds, diabetic ulcers, pressure ulcers, flaps and grafts.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K021501 · printed Nov 4, 2026
Cite this page
510(k) Report. “K021501: V.a.C. Instillamat (Vacuum Assisted Closure Instillamat.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021501
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026