510(k) · Cleared
ClearedLuther Safety Huber Needle Set
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Luther Research Partners · FPA Set, Administration, Intravascular
Cleared on Nov 14, 2002 as substantially equivalent to K993848 (Millennium Medical Distribution, Inc., 2000) after a 185-day review. Its family tree reaches back 2 generations to 1989. 17 later devices descend from it.
- Decided
- Nov 14, 2002
- Review
- 185 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K890127 (1989). 6 ancestors in all. 17 later devices descend from it, 4 citing it directly.
- Root · 2 generations backK890127 Intravascular Administration SetMulti-Med, Inc. · 1989
- 1 generation backK993848 Millennium Huber Plus Safety Infusion SetMillennium Medical Distribution, Inc. · 2000 · Recalled
- This deviceK021565 Luther Safety Huber Needle SetLuther Research Partners · 2002
- Descendant · cites it directly · 14 of its ownK040527 Low Profile Luther Safety HuberLuther Needlesafe Products, Inc. · 2004 · Recalled
- Descendant · cites it directly · 13 of its ownK073050 Safestep Max Power-Injectable Infusion SetSpecialized Health Products International, Inc. · 2008 · Recalled
- Descendant · 2 generations on · 6 of its ownK170897 Surecan Safety II Needle, Surecan Safety II Needle, Surecan Safety…B.Braun Medical, Inc. · 2017
- Descendant · cites it directly · 3 of its ownK032934 MPS Acacia Safeguard Huber DeviceMps Acacia · 2003
- Descendant · 3 generations on · 2 of its ownK230715 Promisemed Safety Huber NeedlePromisemed Hangzhou Meditech Co., Ltd. · 2023
Showing 5 of 17 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 17 · See all- K040527Low Profile Luther Safety HuberLuther Needlesafe Products, Inc. · 2004 · cites it directly14descendants
- K073050Safestep Max Power-Injectable Infusion SetSpecialized Health Products International, Inc. · 2008 · cites it directly13descendants
- K170897Surecan Safety II Needle, Surecan Safety II Needle, Surecan Safety II Needle with…B.Braun Medical, Inc. · 2017 · 2 generations on6descendants
- K032934MPS Acacia Safeguard Huber DeviceMps Acacia · 2003 · cites it directly3descendants
- K230715Promisemed Safety Huber NeedlePromisemed Hangzhou Meditech Co., Ltd. · 2023 · 3 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K890127 | Intravascular Administration Set | Multi-Med, Inc. | 1989 | — |
| −1 | K993848 | Millennium Huber Plus Safety Infusion Set | Millennium Medical Distribution, Inc. | 2000 | 2 |
| 0 (this device) | K021565 | Luther Safety Huber Needle Set | Luther Research Partners | 2002 | — |
| +1 | K040527 | Low Profile Luther Safety Huber | Luther Needlesafe Products, Inc. | 2004 | 2 |
| +1 | K073050 | Safestep Max Power-Injectable Infusion Set | Specialized Health Products International, Inc. | 2008 | 2 |
| +2 | K170897 | Surecan Safety II Needle, Surecan Safety II Needle, Surecan Safety II Needle… | B.Braun Medical, Inc. | 2017 | — |
| +1 | K032934 | MPS Acacia Safeguard Huber Device | Mps Acacia | 2003 | — |
| +3 | K230715 | Promisemed Safety Huber Needle | Promisemed Hangzhou Meditech Co., Ltd. | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1989 | 3 | 0 |
| 1991 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 2 | 0 |
| 2008 | 1 | 0 |
| 2009 | 1 | 0 |
| 2014 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 2 | 0 |
| 2021 | 3 | 0 |
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K993848 | Millennium Huber Plus Safety Infusion SetSummary page 1…Safety Huber Needle and Administration Set Predicate Device: Millennium Huber Plus Safety Infusion Set K993848 Device Descrbtion: The Luther Safety Huber Needle Set is a standard right angle Huber needle and administration… | 2000 |
What descends from it? (17)
See all 174 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 11.0 years on median.
- 2 of the 6 ancestors have a recall of any class.
- Of its descendants, K040527 (Luther Needlesafe Products, Inc., 2004) has gone furthest, with 14 descendants of its own.
- 6 other devices also cite its predicate K993848.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
The Luther Safety Huber Needle Set is a device intended to administer drugs to a patient from a container through a subcutaneous implanted port. The Huber Needle safety needle cover is manually activated. When the safety feature is activated, the device is designed to aid in the prevention of accidental needle sticks.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K021565 · printed Nov 6, 2026
Cite this page
510(k) Report. “K021565: Luther Safety Huber Needle Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K021565
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026