K-Assay LP (a) Assay

K021660510(k) TraditionalCleared Jul 25, 200266-day reviewClass II21 CFR 866.5600

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kamiya Biomedical Co. · DFC Lipoprotein, Low-Density, Antigen, Antiserum, Control

Cleared on Jul 25, 2002 after a 66-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Jul 25, 2002
Review
66 days
Class
Class II
Product code
DFC
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K021660Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DFC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DFC device

  1. #1 K253069 Lipoprotein (a) Molarity Assayscore 11.5 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All DFC devices

DFC Lipoprotein, Low-Density, Antigen, Antiserum, Control: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DFC

1in 2025

2007: 12009: 12012: 22018: 12022: 12025: 12026 (partial year): 1
2007high 2 (2012) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DFC

Too few DFC 510(k)s in any year since 2007 to give a median.

Recalls per year · DFC

2in 2024

2012: 12024: 2
2007high 2 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DFC

7in 2025

2016: 12023: 62024: 162025: 7
2007high 16 (2024) · low 0 (2007)2025

MAUDE reports naming product code DFC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20091—00
20100—00
20110—00
20122—10
20130—00
20140—00
20150—00
20160—01
20170—00
20181—00
20190—00
20200—00
20210—00
20221—00
20230—06
20240—216
20251—07
20261—0—

What is it indicated for?

The Kamiya H-ASSAY do Lp(a) Assay is an in vifmdiagnostic reagent for the quantitative determination of human Lp(a) in human serum by immunoturbidimetric assay. The test may provide in conjunction with other lipoprotein tests, the risk assessment of coronary artery disease for specific populations.

The K-ASSA Y Cp(a) Calibrator Set is an in vitro diagnostic reagent for cafibration ofthe K-ASSAYg Lp(a) Assay.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K021660: K-Assay LP (a) Assay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021660

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)