510(k) Report

510(k) · Cleared

Cleared

Rusch Tracheofix Set, Cuffed and Uncuffed

K021764510(k) TraditionalCleared Jul 23, 200255-day reviewClass II21 CFR 868.5800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rusch Intl. · BTO Tube, Tracheostomy (W/Wo Connector)

Cleared on Jul 23, 2002 after a 55-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.

Decided
Jul 23, 2002
Review
55 days
Class
Class II
Product code
BTO
Recalls
None
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2011: 1 descendant clearedReference device: K972423 · Rusch Tracheofix-Set · Rusch Intl. · 1998200020052010201520202025
  1. This deviceK021764 Rusch Tracheofix Set, Cuffed and UncuffedRusch Intl. · 2002
  2. Descendant · cites it directly · 1 of its ownK042684 Well Lead Tracheostomy TubeWell Lead Medical Instruments · 2005
  3. Descendant · 2 generations on · 0 of its ownK101721 Well Lead Tracheostomy Tube and Disposable Inner CannulaRegulatory and Marketing Services, Inc. · 2011

Most influential descendants

Showing 2 of 2 · See all
  • K042684Well Lead Tracheostomy TubeWell Lead Medical Instruments · 2005 · cites it directly1descendant
  • K101721Well Lead Tracheostomy Tube and Disposable Inner CannulaRegulatory and Marketing Services, Inc. · 2011 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K021764Rusch Tracheofix Set, Cuffed and UncuffedRusch Intl.2002—
+1K042684Well Lead Tracheostomy TubeWell Lead Medical Instruments2005—
+2K101721Well Lead Tracheostomy Tube and Disposable Inner CannulaRegulatory and Marketing Services, Inc.2011—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
201110
FIG. 1 — Lineage of K021764, 2002–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BTO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTO device

  1. #1 K242921 5300600-5301000 Rota-Trach Disposable Standard…score 13.7 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Mallinckrodt Shiley DCT Tracheostomy Tube Cuffed and Uncuffed
Named without a submission number
—
*—Smiths Industries (SIMS Concord-Portex) D.I.C. (Disposable Inner Cannula) Tracheostomy…
Named without a submission number
—
*—Bivona Medical Technologies AIRE-CUP Tracheostomy Tube
Named without a submission number
—
*—Rusch Crystal Tracheostomy Tube
Named without a submission number
—
*—Rusch TracheoFlex Sets
Named without a submission number
—
†K972423Rusch Tracheofix-SetRusch Intl.1998—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K042684Well Lead Tracheostomy TubeWell Lead Medical Instruments20051

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K042684 (Well Lead Medical Instruments, 2005) has gone furthest, with 1 descendant of its own.

How does its category compare?

All BTO devices

BTO Tube, Tracheostomy (W/Wo Connector): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BTO

1in 2025

2007: 12008: 12009: 12010: 32011: 12012: 12018: 12020: 12024: 12025: 12026 (partial year): 1
2007high 3 (2010) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTO

98in 2010

2010: 98 days median
2007high 98 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTO

1in 2023

2009: 22010: 62011: 192012: 12015: 12023: 1, 1 Class I2026 (partial year): 1
2007high 19 (2011) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · BTO

233in 2025

2007: 2262008: 2552009: 7952010: 1302011: 542012: 822013: 782014: 1732015: 1722016: 2122017: 1262018: 1622019: 872020: 1132021: 1982022: 7702023: 4022024: 4182025: 233
2007high 795 (2009) · low 54 (2011)2025

MAUDE reports naming product code BTO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—0226
20081—0255
20091—2795
20103986130
20111—1954
20121—182
20130—078
20140—0173
20150—1172
20160—0212
20170—0126
20181—0162
20190—087
20201—0113
20210—0198
20220—0770
20230—1 (1)402
20241—0418
20251—0233
20261—1—

What is it indicated for?

The Rusch TracheoFix Set (TFS) is a single patient disposable tracheostomy tube for airway management of tracheostomized patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K021764: Rusch Tracheofix Set, Cuffed and Uncuffed.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021764

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026