510(k) · Cleared
ClearedModification to Kodak Directview CR 800/900 System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Eastman Kodak Company · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)
Cleared on Jul 2, 2002 after a 28-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.
- Decided
- Jul 2, 2002
- Review
- 28 days
- Class
- Class II
- Product code
- MQB
- Recalls
- None
- Predicates
- 0
2 later devices descend from it, 1 citing it directly.
- This deviceK021829 Modification to Kodak Directview CR 800/900 SystemEastman Kodak Company · 2002
- Descendant · cites it directly · 1 of its ownK073670 Kodak Point of Care CR 120, Kodak Point of Care CR 140, Kodak Point…Orex Computed Radiography, Ltd. · 2008
- Descendant · 2 generations on · 0 of its ownK192894 Vita Flex CR System with LLICarestream Health, Inc. · 2020
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K021829 | Modification to Kodak Directview CR 800/900 System | Eastman Kodak Company | 2002 | — |
| +1 | K073670 | Kodak Point of Care CR 120, Kodak Point of Care CR 140, Kodak Point of Care CR… | Orex Computed Radiography, Ltd. | 2008 | — |
| +2 | K192894 | Vita Flex CR System with LLI | Carestream Health, Inc. | 2020 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQB device
- #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Kodak DirectView CR 800/900 System Named without a submission number |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K073670 | Kodak Point of Care CR 120, Kodak Point of Care CR 140, Kodak Point of Care CR 260 | 2008 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K073670 (Orex Computed Radiography, Ltd., 2008) has gone furthest, with 1 descendant of its own.
How does its category compare?
All MQB devicesMQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MQB
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MQB
127in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQB
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQB
141in 2025
MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 22 | 15 | 25 |
| 2008 | 8 | 15 | 36 | 30 |
| 2009 | 15 | 57 | 19 | 34 |
| 2010 | 11 | 116 | 14 | 39 |
| 2011 | 24 | 102 | 10 | 101 |
| 2012 | 22 | 80 | 8 | 267 |
| 2013 | 21 | 105 | 6 | 159 |
| 2014 | 32 | 102 | 0 | 29 |
| 2015 | 21 | 81 | 0 | 21 |
| 2016 | 22 | 92 | 0 | 26 |
| 2017 | 31 | 30 | 1 | 20 |
| 2018 | 16 | 30 | 4 | 84 |
| 2019 | 22 | 30 | 1 | 45 |
| 2020 | 19 | 28 | 4 | 9 |
| 2021 | 21 | 48 | 1 | 26 |
| 2022 | 31 | 48 | 0 | 13 |
| 2023 | 10 | 30 | 0 | 51 |
| 2024 | 8 | 187 | 0 | 91 |
| 2025 | 8 | 127 | 1 | 141 |
| 2026 | 3 | 245 | 1 | — |
What is it indicated for?
The KODAK DirectView CR Long-Length Imaging System is used with the KODAK DirectView CR 800/ CR 900 Systems which are compact laser scanners capable of reading the latent image formed on a storage phosphor imaging plate and producing a digital image for projection radiology applications. The Long-Length Imaging feature is used for examinations of long areas of anatomy such as the leg and spine.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K021829 · printed Nov 6, 2026
Cite this page
510(k) Report. “K021829: Modification to Kodak Directview CR 800/900 System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K021829
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026