K022198510(k) TraditionalCleared Mar 21, 2003259-day reviewClass II21 CFR 882.1480

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Richard Wolf Medical Instruments Corp. · GWG Endoscope, Neurological

Cleared on Mar 21, 2003 as substantially equivalent to K970162 (Richard Wolf Medical Instruments Corp., 1997) and 1 other predicate after a 259-day review. Its family tree reaches back 2 generations to 1994.

Decided
Mar 21, 2003
Review
259 days
Class
Class II
Product code
GWG
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K941239 (1994). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1998: 1 other ancestorK941239 · Aesculap Neuroendoscope · Aesculap, Inc. · 1994K970162 · Neurological Endoscope · Richard Wolf Medical Instruments Corp. · 19971990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor K970162 · Neurological Endoscope · Richard Wolf Medical Instruments Corp. · 1997K941239 · Aesculap Neuroendoscope · Aesculap, Inc. · 19940
  1. Root · 2 generations backK941239 Aesculap NeuroendoscopeAesculap, Inc. · 1994
  2. 1 generation backK970162 Neurological EndoscopeRichard Wolf Medical Instruments Corp. · 1997
  3. This deviceK022198 Endoscope Set for Magnetic Resonance (MR), Models 8767.412, 8767.121…Richard Wolf Medical Instruments Corp. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941239Aesculap NeuroendoscopeAesculap, Inc.1994—
−1K970162Neurological EndoscopeRichard Wolf Medical Instruments Corp.1997—
0 (this device)K022198Endoscope Set for Magnetic Resonance (MR), Models 8767.412, 8767.121 & 8767.452Richard Wolf Medical Instruments Corp.2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
FIG. 1 — Lineage of K022198, 1994–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWG device

  1. #1 K211202 1688 4K Camera System, L11 LED Light Source…score 22.5 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K970162Neurological Endoscope
Summary page 1
…name: Endoscopes, rigid Endoscopes, neurological 5 10(k) Trade or proprietary or model name Manufacturer Number 1 K970162 1 Neurological Endoscope Set 1 Richard Wolf 2 K973405 2 Endoscopic Spine System 2 Ri…
Richard Wolf Medical Instruments Corp.1997—
*K973405Yeung Endoscopic Spine System
Summary page 1
…5 10(k) Trade or proprietary or model name Manufacturer Number 1 K970162 1 Neurological Endoscope Set 1 Richard Wolf 2 K973405 2 Endoscopic Spine System 2 Richard Wolf 1.O Description The submitted endoscope set is equivale…
Richard Wolf Medical Instruments Corp.1998—

Also cleared against K970162: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 5.4 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K970162.

How does its category compare?

All GWG devices

GWG Endoscope, Neurological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GWG

2in 2025

2008: 22013: 12014: 22016: 22017: 42018: 42019: 32020: 22021: 32023: 52024: 12025: 22026 (partial year): 4
2007high 5 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWG

269in 2023

2017: 126 days median2018: 128 days median2019: 156 days median2021: 106 days median2023: 269 days median2026 (partial year): 217 days median
2007high 269 (2023) · low 106 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWG

2in 2011

2009: 12011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWG

33in 2025

2007: 32008: 52010: 12011: 42012: 72013: 32014: 192015: 372016: 252017: 122018: 162019: 102020: 192021: 212022: 122023: 92024: 92025: 33
2007high 37 (2015) · low 0 (2009)2025

MAUDE reports naming product code GWG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—03
20082—05
20090—10
20100—01
20110—24
20120—07
20131—03
20142—019
20150—037
20162—025
20174126012
20184128016
20193156010
20202—019
20213106021
20220—012
2023526909
20241—09
20252—033
202642170—

What is it indicated for?

The MR Endoscope by Tronnier (Magnetic Resonance) allows visual observation of the operating site with simultaneous utilization of the working, supply and drain channels.

The Obturator is used for atraumatic insertion of the endoscope.

For examination, diagnosis and therapy in neurosurgery in conjunction with endoscopic accessories during intracranial procedures, such as: the fenestration of cysts, the removal of cysts, biopsies of lesions, coagulation of intraventricular lesions, etc.

NOTE: The MR Endoscope is specially designed for use in open nuclear magnetic resonance tomographs.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K022198: Endoscope Set for Magnetic Resonance (MR), Models 8767.412, 8767.121 & 8767.452.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K022198

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026