510(k) · Cleared
Recalled · 2009Normed Titanium Osteotomy Plating System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Osteomedics, Inc. · HRS Plate, Fixation, Bone
Cleared on Sep 9, 2002 after a 54-day review. The FDA summary names no predicate by number. 521 later devices descend from it. It has been recalled once.
- Decided
- Sep 9, 2002
- Review
- 54 days
- Class
- Class II
- Product code
- HRS
- Recalls
- 1
- Predicates
- 0
521 later devices descend from it, 5 citing it directly.
- This deviceK022325 Normed Titanium Osteotomy Plating SystemOsteomedics, Inc. · 2002
- Descendant · cites it directly · 410 of its ownK061808 Darco Locking Bone Plate SystemDarco International, Inc. · 2006 · Recalled
- Descendant · 2 generations on · 342 of its ownK073624 Modular Foot SystemOrthohelix Surgical Designs, Inc. · 2008 · Recalled
- Descendant · 3 generations on · 339 of its ownK100618 Maxlock Extreme Extremity Plating System with Variable Angle…Orthohelix Surgical Designs, Inc. · 2010
- Descendant · 2 generations on · 256 of its ownK081513 Merete 3.0 and 3.5 MM Locking ScrewsMerete Medical GmbH · 2008
- Descendant · cites it directly · 249 of its ownK040907 Arthrex Small Fragment Plates and ScrewsArthrex, Inc. · 2004
Showing 5 of 521 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 521 · See all- K061808Darco Locking Bone Plate SystemDarco International, Inc. · 2006 · cites it directly410descendants
- K073624Modular Foot SystemOrthohelix Surgical Designs, Inc. · 2008 · 2 generations on342descendants
- K100618Maxlock Extreme Extremity Plating System with Variable Angle TechnologyOrthohelix Surgical Designs, Inc. · 2010 · 3 generations on339descendants
- K081513Merete 3.0 and 3.5 MM Locking ScrewsMerete Medical GmbH · 2008 · 2 generations on256descendants
- K040907Arthrex Small Fragment Plates and ScrewsArthrex, Inc. · 2004 · cites it directly249descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K022325 | Normed Titanium Osteotomy Plating System | Osteomedics, Inc. | 2002 | — |
| +1 | K061808 | Darco Locking Bone Plate System | Darco International, Inc. | 2006 | 3 |
| +2 | K073624 | Modular Foot System | Orthohelix Surgical Designs, Inc. | 2008 | 1 |
| +3 | K100618 | Maxlock Extreme Extremity Plating System with Variable Angle Technology | Orthohelix Surgical Designs, Inc. | 2010 | — |
| +2 | K081513 | Merete 3.0 and 3.5 MM Locking Screws | Merete Medical GmbH | 2008 | — |
| +1 | K040907 | Arthrex Small Fragment Plates and Screws | Arthrex, Inc. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2005 | 3 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 2 | 0 |
| 2009 | 2 | 0 |
| 2010 | 8 | 0 |
| 2011 | 7 | 0 |
| 2012 | 19 | 0 |
| 2013 | 18 | 0 |
| 2014 | 26 | 0 |
| 2015 | 42 | 0 |
| 2016 | 18 | 0 |
| 2017 | 46 | 0 |
| 2018 | 21 | 0 |
| 2019 | 26 | 0 |
| 2020 | 38 | 0 |
| 2021 | 31 | 0 |
| 2022 | 35 | 0 |
| 2023 | 37 | 0 |
| 2024 | 49 | 0 |
| 2025 | 39 | 0 |
| 2026 | 50 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (521)
See all 5215 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Apr 14, 2009 | Not classified | Z-1524-2009 | Pending | Screwdriver used with the Ascension Total Foot System not manufactured to specification, resulting in the driver not properly engaging and/or stripping the screws making it difficult to properly seat the screws during surgery. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K061808 (Darco International, Inc., 2006) has gone furthest, with 410 descendants of its own.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The Normed Titanium Osteotomy Plating System intended for use in stabilization and fixation of fresh fractures, revision procedures, joint fusion, and reconstruction of small bones of the hand, feet, wrist, ankles, fingers and toes skeleton. The system can be used in both adult and pediatric patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K022325 · printed Nov 6, 2026
Cite this page
510(k) Report. “K022325: Normed Titanium Osteotomy Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K022325
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026