Micrus Stretch-Resistant Microcoil System, MSR01

K022420510(k) TraditionalCleared Oct 22, 200290-day reviewClass II21 CFR 882.5950

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Micrus Corp. · HCG Device, Neurovascular Embolization

Cleared on Oct 22, 2002 as substantially equivalent to K993415 (Boston Scientific, Target, 2000) after a 90-day review. Its family tree reaches back 5 generations to 1995. 1 of the 128 devices in its family, counting itself, has a Class I recall. 103 later devices descend from it.

Decided
Oct 22, 2002
Review
90 days
Class
Class II
Product code
HCG
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K951256 (1995). 24 ancestors in all, the oldest K860840 (1986). 103 later devices descend from it, 4 citing it directly. 1 of the 128 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1994: 2 other ancestors1997: 1 other ancestor1996: 2 other ancestors1995: 2 other ancestors1992: 5 other ancestors1991: 2 other ancestors1989: 1 other ancestor1988: 3 other ancestors1986: 1 other ancestor2007: 5 descendants cleared2008: 8 descendants cleared2004: 2 descendants cleared2003: 3 descendants cleared2005: 2 descendants cleared2012: 7 descendants cleared2009: 9 descendants cleared2013: 11 descendants cleared2017: 5 descendants cleared2006: 1 descendant cleared2014: 6 descendants cleared2015: 6 descendants cleared2011: 5 descendants cleared2010: 4 descendants cleared2021: 4 descendants cleared2022: 6 descendants cleared, 1 with a Class I recall12020: 3 descendants cleared2016: 3 descendants cleared2018: 4 descendants cleared2026: 4 descendants cleared2023: 1 descendant cleared2019: 1 descendant cleared2025: 2 descendants cleared2024: 1 descendant clearedK951256 · Detachable Platinum Coil (Guglielmi Detachable Coil, GDC) · Target Therapeutics · 1995×2: 2 generations cleared close together, K960705 (1996), K962503 (1996) K971395 · Guglielmi Detachable Coil (GDC), Fibered Platinum Coil, .035 Type, Berenstein Liquid Coil, Fibered Platinum Coils, Acce · Target Therapeutics · 1997K993415 · GDC-10 Stretch Resistant Guglielmi Detachable Coil, GDC-10 2-Diameter Stretch Resistant Guglielmi Detachable Coil, GDC-1 · Boston Scientific, Target · 20001990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 17 other ancestors4 generations back: 1 other ancestor 1 generation forward: 4 descendants2 generations forward: 11 descendants3 generations forward: 16 descendants4 generations forward: 23 descendants, 1 with a Class I recall15 generations forward: 25 descendants6 generations forward: 8 descendants7 generations forward: 8 descendants8 generations forward: 1 descendant9 generations forward: 1 descendant10 generations forward: 2 descendants11 generations forward: 2 descendants12 generations forward: 1 descendant13 generations forward: 1 descendant K993415 · GDC-10 Stretch Resistant Guglielmi Detachable Coil, GDC-10 2-Diameter Stretch Resistant Guglielmi Detachable Coil, GDC-1 · Boston Scientific, Target · 2000K971395 · Guglielmi Detachable Coil (GDC), Fibered Platinum Coil, .035 Type, Berenstein Liquid Coil, Fibered Platinum Coils, Acce · Target Therapeutics · 1997K962503 · Guglielmi Detachable Coil · Target Therapeutics · 1996K960705 · Guglielmi Detachable Coil · Target Therapeutics · 1996K951256 · Detachable Platinum Coil (Guglielmi Detachable Coil, GDC) · Target Therapeutics · 1995−50+5+10
  1. Root · 5 generations backK951256 Detachable Platinum Coil (Guglielmi Detachable Coil, GDC)Target Therapeutics · 1995
  2. 4 generations backK960705 Guglielmi Detachable CoilTarget Therapeutics · 1996
  3. 3 generations backK962503 Guglielmi Detachable CoilTarget Therapeutics · 1996
  4. 2 generations backK971395 Guglielmi Detachable Coil (GDC), Fibered Platinum Coil, .035 Type…Target Therapeutics · 1997
  5. 1 generation backK993415 GDC-10 Stretch Resistant Guglielmi Detachable Coil, GDC-10…Boston Scientific, Target · 2000
  6. This deviceK022420 Micrus Stretch-Resistant Microcoil System, MSR01Micrus Corp. · 2002
  7. Descendant · cites it directly · 91 of its ownK031578 Micrus Microcoil Systems, Models Hel, SPH, STR, FSR and HSRMicrus Corp. · 2003
  8. Descendant · 2 generations on · 68 of its ownK032590 Microplex Coil System (MCS), Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2003
  9. Descendant · 3 generations on · 67 of its ownK033836 Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2003
  10. Descendant · 3 generations on · 66 of its ownK041551 Modification to: Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2004
  11. Descendant · 2 generations on · 65 of its ownK050954 Microplex Coil System (MCS) and Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2005 · Recalled

Showing 5 of 103 descendants. See all descendants

Descendants cleared per year

2003: 32004: 22005: 22006: 12007: 52008: 82009: 92010: 42011: 52012: 72013: 112014: 62015: 62016: 32017: 52018: 42019: 12020: 32021: 42022: 62023: 12024: 12025: 22026: 4
2003high 11 (2013) · low 1 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 103 · See all
  • K031578Micrus Microcoil Systems, Models Hel, SPH, STR, FSR and HSRMicrus Corp. · 2003 · cites it directly91descendants
  • K032590Microplex Coil System (MCS), Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2003 · 2 generations on68descendants
  • K033836Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2003 · 3 generations on67descendants
  • K041551Modification to: Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2004 · 3 generations on66descendants
  • K050954Microplex Coil System (MCS) and Hydrocoil Embolic System (Hes)MicroVention, Inc. · 2005 · 2 generations on65descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K951256Detachable Platinum Coil (Guglielmi Detachable Coil, GDC)Target Therapeutics1995—
−4K960705Guglielmi Detachable CoilTarget Therapeutics1996—
−3K962503Guglielmi Detachable CoilTarget Therapeutics1996—
−2K971395Guglielmi Detachable Coil (GDC), Fibered Platinum Coil, .035 Type, Berenstein…Target Therapeutics1997—
−1K993415GDC-10 Stretch Resistant Guglielmi Detachable Coil, GDC-10 2-Diameter Stretch…Boston Scientific, Target2000—
0 (this device)K022420Micrus Stretch-Resistant Microcoil System, MSR01Micrus Corp.2002—
+1K031578Micrus Microcoil Systems, Models Hel, SPH, STR, FSR and HSRMicrus Corp.2003—
+2K032590Microplex Coil System (MCS), Hydrocoil Embolic System (Hes)MicroVention, Inc.2003—
+3K033836Hydrocoil Embolic System (Hes)MicroVention, Inc.2003—
+3K041551Modification to: Hydrocoil Embolic System (Hes)MicroVention, Inc.2004—
+2K050954Microplex Coil System (MCS) and Hydrocoil Embolic System (Hes)MicroVention, Inc.200516

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198830
198910
199120
199250
199420
199520
199620
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200330
200420
200520
200610
200750
200880
200990
201040
201150
201270
2013110
201460
201560
201630
201750
201840
201910
202030
202140
202261
202310
202410
202520
202640
FIG. 1 — Lineage of K022420, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HCG device

  1. #1 K252700 Optima Coil System (Optima Packing Coil System)score 20.6 · 26 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K993415GDC-10 Stretch Resistant Guglielmi Detachable Coil, GDC-10 2-Diameter Stretch Resistant…
Summary page 1
…scription Clearance Date K9993415 GDC-IO and GDC-10 (2D) Stretch Resistant 01/21/2000 Detachable Coils and GDC-…
Boston Scientific, Target2000—
Kept off the family treeK020056FDA’s K020056 is Duet Suture Anchor
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
Bionx Implants, Ltd.2002—

Also cleared against K993415: 2 other devices →

What descends from it? (103)

See all 103

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031578Micrus Microcoil Systems, Models Hel, SPH, STR, FSR and HSRMicrus Corp.200391
K033813Micrus Modified Microcoil System, CerecyteMicrus Corp.200440
K063653Micrus Microcoil System, Cashmere Model SRCMicrus Endovascular Corporation200735
K080379Micrus Microcoil System, Deltapaq 10 Stretch ResistantMicrus Endovascular Corporation200810

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K220040CEREPAK Uniform, Uniform XL, Uniform 3D, Heliform Soft, Heliform XtraSoft, Heliform XL, Heliform XtraSoft…Medos International SARL · 2022 · 4 generations on · ◆ in the 2022 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 10 months on median.
  • 2 of the 24 ancestors have a recall of any class.
  • Of its descendants, K031578 (Micrus Corp., 2003) has gone furthest, with 91 descendants of its own.
  • 2 other devices also cite its predicate K993415.

How does its category compare?

All HCG devices

HCG Device, Neurovascular Embolization: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HCG

3in 2025

2007: 82008: 92009: 72010: 82011: 92012: 72013: 72014: 52015: 52016: 72017: 52018: 42019: 12020: 22021: 52022: 32023: 22024: 42025: 32026 (partial year): 4
2007high 9 (2008) · low 1 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HCG

107in 2025

2007: 50 days median2008: 71 days median2009: 48 days median2010: 72 days median2011: 78 days median2012: 30 days median2013: 67 days median2014: 66 days median2015: 60 days median2016: 37 days median2017: 97 days median2018: 173 days median2021: 103 days median2022: 114 days median2024: 49 days median2025: 107 days median2026 (partial year): 30 days median
2007high 173 (2018) · low 30 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HCG

1in 2025

2007: 12008: 32010: 22011: 12013: 22014: 42022: 22024: 12025: 1, 1 Class I2026 (partial year): 1
2007high 4 (2014) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · HCG

537in 2025

2007: 3262008: 7302009: 8212010: 8512011: 8942012: 1,1462013: 1,1032014: 1,7292015: 1,5982016: 1,9912017: 2,4942018: 2,0582019: 1,7632020: 1,7542021: 2,2682022: 6632023: 5682024: 5522025: 537
2007high 2,494 (2017) · low 326 (2007)2025

MAUDE reports naming product code HCG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20078501326
20089713730
20097480821
20108722851
20119781894
201273001,146
201376721,103
201456641,729
201556001,598
201673701,991
201759702,494
2018417302,058
20191—01,763
20202—01,754
2021510302,268
202231142663
20232—0568
20244491552
202531071 (1)537
20264301—

What is it indicated for?

The Micrus Stretch-Resistant Microcoil System is intended for endovascular embolization of intracranial aneurysms that - because of their morphology, their location or the patient’s general medical condition - are considered by the treating neurosurgical team to be a) very high risk for management by traditional operative techniques or b) inoperable.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K022420: Micrus Stretch-Resistant Microcoil System, MSR01.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K022420

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026