510(k) Report

510(k) · Cleared

Cleared

Contour SE Microspheres

K022427510(k) SpecialCleared Aug 22, 200228-day reviewClass II21 CFR 882.5950

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corp · HCG Device, Neurovascular Embolization

Cleared on Aug 22, 2002 after a 28-day review. The FDA summary names its predicate without a number. 23 later devices descend from it.

Decided
Aug 22, 2002
Review
28 days
Class
Class II
Product code
HCG
Recalls
None
Predicates
0

23 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2006: 2 descendants cleared2004: 1 descendant cleared2008: 3 descendants cleared2012: 2 descendants cleared2015: 1 descendant cleared2013: 2 descendants cleared2014: 4 descendants cleared2018: 3 descendants cleared2016: 1 descendant cleared2017: 1 descendant cleared2024: 1 descendant cleared2019: 2 descendants cleared200020052010201520202025
  1. This deviceK022427 Contour SE MicrospheresBoston Scientific Corp · 2002
  2. Descendant · cites it directly · 11 of its ownK052742 Hepasphere MicrospheresBiosphere Medical, Inc. · 2006
  3. Descendant · cites it directly · 10 of its ownK034068 Contour SE MicrospheresBoston Scientific Corp · 2004
  4. Descendant · 2 generations on · 8 of its ownK113266 Gel-Block Embolization PledgetsVascular Solutions, Inc. · 2012
  5. Descendant · 2 generations on · 6 of its ownK073417 Embozene MicrospheresCelonova Biosciences, Inc. · 2008
  6. Descendant · 3 generations on · 4 of its ownK132675 Embozene MicrospheresCelonova Biosciences, Inc. · 2013

Showing 5 of 23 descendants. See all descendants

Descendants cleared per year

2004: 12006: 22008: 32012: 22013: 22014: 42015: 12016: 12017: 12018: 32019: 22024: 1
2004high 4 (2014) · low 0 (2005)2026

Most influential descendants

Showing 5 of 23 · See all
  • K052742Hepasphere MicrospheresBiosphere Medical, Inc. · 2006 · cites it directly11descendants
  • K034068Contour SE MicrospheresBoston Scientific Corp · 2004 · cites it directly10descendants
  • K113266Gel-Block Embolization PledgetsVascular Solutions, Inc. · 2012 · 2 generations on8descendants
  • K073417Embozene MicrospheresCelonova Biosciences, Inc. · 2008 · 2 generations on6descendants
  • K132675Embozene MicrospheresCelonova Biosciences, Inc. · 2013 · 3 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K022427Contour SE MicrospheresBoston Scientific Corp2002—
+1K052742Hepasphere MicrospheresBiosphere Medical, Inc.2006—
+1K034068Contour SE MicrospheresBoston Scientific Corp2004—
+2K113266Gel-Block Embolization PledgetsVascular Solutions, Inc.2012—
+2K073417Embozene MicrospheresCelonova Biosciences, Inc.2008—
+3K132675Embozene MicrospheresCelonova Biosciences, Inc.2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200620
200830
201220
201320
201440
201510
201610
201710
201830
201920
202410
FIG. 1 — Lineage of K022427, 2002–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HCG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HCG device

  1. #1 K252700 Optima Coil System (Optima Packing Coil System)score 20.6 · 26 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Contour Emboli PVA
Named without a submission number
—
*—Embosphere Microspheres
Named without a submission number
—
*—EmboGold Microspehers
Named without a submission number
—

What descends from it? (23)

See all 23

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052742Hepasphere MicrospheresBiosphere Medical, Inc.200611
K034068Contour SE MicrospheresBoston Scientific Corp200410

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K052742 (Biosphere Medical, Inc., 2006) has gone furthest, with 11 descendants of its own.

How does its category compare?

All HCG devices

HCG Device, Neurovascular Embolization: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HCG

3in 2025

2007: 82008: 92009: 72010: 82011: 92012: 72013: 72014: 52015: 52016: 72017: 52018: 42019: 12020: 22021: 52022: 32023: 22024: 42025: 32026 (partial year): 4
2007high 9 (2008) · low 1 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HCG

107in 2025

2007: 50 days median2008: 71 days median2009: 48 days median2010: 72 days median2011: 78 days median2012: 30 days median2013: 67 days median2014: 66 days median2015: 60 days median2016: 37 days median2017: 97 days median2018: 173 days median2021: 103 days median2022: 114 days median2024: 49 days median2025: 107 days median2026 (partial year): 30 days median
2007high 173 (2018) · low 30 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HCG

1in 2025

2007: 12008: 32010: 22011: 12013: 22014: 42022: 22024: 12025: 1, 1 Class I2026 (partial year): 1
2007high 4 (2014) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · HCG

537in 2025

2007: 3262008: 7302009: 8212010: 8512011: 8942012: 1,1462013: 1,1032014: 1,7292015: 1,5982016: 1,9912017: 2,4942018: 2,0582019: 1,7632020: 1,7542021: 2,2682022: 6632023: 5682024: 5522025: 537
2007high 2,494 (2017) · low 326 (2007)2025

MAUDE reports naming product code HCG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20078501326
20089713730
20097480821
20108722851
20119781894
201273001,146
201376721,103
201456641,729
201556001,598
201673701,991
201759702,494
2018417302,058
20191—01,763
20202—01,754
2021510302,268
202231142663
20232—0568
20244491552
202531071 (1)537
20264301—

What is it indicated for?

Contour SETMMicrospheres are indicated for use for the embolization of hypervascular tumors and arteriovenous malformations.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K022427: Contour SE Microspheres.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K022427

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026