510(k) · Cleared
ClearedExcalibur 9000 Totalsense Quad Head Array Coil
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Usa Instruments, Inc. · MOS Coil, Magnetic Resonance, Specialty
Cleared on Oct 22, 2002 as substantially equivalent to K001870 (Usa Instruments, Inc., 2000) and 1 other predicate after a 78-day review. Its family tree reaches back 1 generation to 1997. 6 later devices descend from it.
- Decided
- Oct 22, 2002
- Review
- 78 days
- Class
- Class II
- Product code
- MOS
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K964531 (1997). 2 ancestors in all. 6 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK964531 Profile 70000 Quadrature Volume Neck CoilUs Asia Instruments, Inc. · 1997
- This deviceK022582 Excalibur 9000 Totalsense Quad Head Array CoilUsa Instruments, Inc. · 2002
- Descendant · cites it directly · 5 of its ownK041487 QD Head Speeder with Speeder NV AttachmentUsa Instruments, Inc. · 2004
- Descendant · 2 generations on · 4 of its ownK083160 1.5T Atlas Speeder Head-Neck CoilQuality Electrodynamics · 2008 · Recalled
- Descendant · 3 generations on · 1 of its ownK142802 Atlas SPEEDER Head/NeckQuality Electrodynamics, LLC · 2014
- Descendant · 4 generations on · 0 of its ownK151829 Atlas SPEEDER Header/NeckQuality Electrodynamics, LLC · 2015
- Descendant · 3 generations on · 0 of its ownK122638 Toshiba 3T 32CH Head Speeder Coil,Quality Electrodynamics · 2012
Showing 5 of 6 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 6 · See all- K041487QD Head Speeder with Speeder NV AttachmentUsa Instruments, Inc. · 2004 · cites it directly5descendants
- K0831601.5T Atlas Speeder Head-Neck CoilQuality Electrodynamics · 2008 · 2 generations on4descendants
- K142802Atlas SPEEDER Head/NeckQuality Electrodynamics, LLC · 2014 · 3 generations on1descendant
- K151829Atlas SPEEDER Header/NeckQuality Electrodynamics, LLC · 2015 · 4 generations on0descendants
- K122638Toshiba 3T 32CH Head Speeder Coil,Quality Electrodynamics · 2012 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K964531 | Profile 70000 Quadrature Volume Neck Coil | Us Asia Instruments, Inc. | 1997 | — |
| 0 (this device) | K022582 | Excalibur 9000 Totalsense Quad Head Array Coil | Usa Instruments, Inc. | 2002 | — |
| +1 | K041487 | QD Head Speeder with Speeder NV Attachment | Usa Instruments, Inc. | 2004 | — |
| +2 | K083160 | 1.5T Atlas Speeder Head-Neck Coil | Quality Electrodynamics | 2008 | 1 |
| +3 | K142802 | Atlas SPEEDER Head/Neck | Quality Electrodynamics, LLC | 2014 | — |
| +4 | K151829 | Atlas SPEEDER Header/Neck | Quality Electrodynamics, LLC | 2015 | — |
| +3 | K122638 | Toshiba 3T 32CH Head Speeder Coil, | Quality Electrodynamics | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2008 | 1 | 0 |
| 2010 | 1 | 0 |
| 2012 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MOS device
- #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K001870 | Millennium 9000 Phased Array Neurovascular CoilSummary page 2…he Millennium 9000 Phased Array Decoupling isolates the coil elements Neurovascular Coil manufactured by USA from RF fields during RF transmission; Instruments, Inc. (K001870) length of cable and stiffness does not permit looping. USA Instruments, Inc. Excalibur 9000… | 2000 |
| * | K964531 | Profile 70000 Quadrature Volume Neck CoilSummary page 2…o the Profile 7000 Quadrature Volume Neck Coil manufactured by USA Instruments, Inc. (K964531) Coil Design: Receive-only quadrature - Similar to the Millennium 9000 Phased Array phased array coil. Neur… | 1997 |
What descends from it? (6)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K041487 | QD Head Speeder with Speeder NV Attachment | 2004 | 5 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All MOS devicesMOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MOS
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MOS
59in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MOS
13in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MOS
2in 2025
MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 19 | 0 | 4 |
| 2008 | 19 | 33 | 2 | 2 |
| 2009 | 10 | 43 | 0 | 5 |
| 2010 | 16 | 78 | 1 | 13 |
| 2011 | 25 | 57 | 0 | 7 |
| 2012 | 15 | 49 | 1 | 12 |
| 2013 | 7 | 87 | 0 | 10 |
| 2014 | 12 | 60 | 0 | 4 |
| 2015 | 6 | 58 | 2 | 5 |
| 2016 | 11 | 42 | 0 | 7 |
| 2017 | 9 | 63 | 0 | 9 |
| 2018 | 10 | 30 | 0 | 7 |
| 2019 | 3 | 178 | 8 | 8 |
| 2020 | 5 | 51 | 1 | 2 |
| 2021 | 4 | 41 | 0 | 3 |
| 2022 | 11 | 79 | 0 | 5 |
| 2023 | 10 | 59 | 0 | 4 |
| 2024 | 10 | 39 | 13 | 8 |
| 2025 | 3 | 59 | 0 | 2 |
| 2026 | 10 | 45 | 0 | — |
What is it indicated for?
The Excalibur 9000 TotalSENSETMQuad Array Head Coil is designed to provide Magnetic Resonance Images of the brain, upper cervical spine, and the soft tissues and vasculature of the head and neck. The Excalibur 9000 TotalSENSETMQuad Array Head Coil is designed for use with the Toshiba 1.5T scanner manufactured by Toshiba Medical Systems. Anatomic Regions: brain, upper cervical spine, and the soft tissues and vasculature of the head and neck. Nuclei…
Read the full statement (158 words)
The Excalibur 9000 TotalSENSETMQuad Array Head Coil is designed to provide Magnetic Resonance Images of the brain, upper cervical spine, and the soft tissues and vasculature of the head and neck. The Excalibur 9000 TotalSENSETMQuad Array Head Coil is designed for use with the Toshiba 1.5T scanner manufactured by Toshiba Medical Systems.
Anatomic Regions: brain, upper cervical spine, and the soft tissues and vasculature of the head and neck.
Nuclei Excited: Hydrogen
The indications for use are the same as for standard imaging:
The 1.5T MRI system is indicated for use as an NMR device that produces images that: (1) correspond to the distribution of protons exhibiting NMR signal, (2) depend upon NMR parameters (proton density, spin lattice relaxation time T1, spin-spin relaxation time T2) and (3) display the soft tissue structure of the head and whole body. When interpreted by a trained physician, these images yield information that can be useful in the determination of a diagnosis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K022582 · printed Nov 4, 2026
Cite this page
510(k) Report. “K022582: Excalibur 9000 Totalsense Quad Head Array Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K022582
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026