510(k) · Cleared
ClearedCem-Ostetic, Models Cemo-020O, Cemo-05P, Cemo-10P, Cemo-20P, and Cemo-30P
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Berkeley Advanced Biomaterials, Inc. · MQV Filler, Bone Void, Calcium Compound
Cleared on Jan 9, 2003 after a 155-day review. The FDA summary names its predicate without a number. 13 later devices descend from it.
- Decided
- Jan 9, 2003
- Review
- 155 days
- Class
- Class II
- Product code
- MQV
- Recalls
- None
- Predicates
- 0
13 later devices descend from it, 3 citing it directly.
- This deviceK022622 Cem-Ostetic, Models Cemo-020O, Cemo-05P, Cemo-10P, Cemo-20P, and…Berkeley Advanced Biomaterials, Inc. · 2003
- Descendant · cites it directly · 10 of its ownK051951 Cerament Bone Void FillerBonesupport AB · 2005
- Descendant · 2 generations on · 6 of its ownK073316 Cerament Bone Void Filler, Model A0210Bonesupport AB · 2008
- Descendant · 3 generations on · 3 of its ownK201535 Cerament Bone Void FillerBonesupport AB · 2020
- Descendant · 4 generations on · 2 of its ownK212083 Tactoset Injectable Bone SubstituteAnika Therapeutics, Inc. · 2021
- Descendant · 2 generations on · 2 of its ownK071004 Osteocrete Bone Void FillerBone Solutions, Inc. · 2009
Showing 5 of 13 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 13 · See all- K051951Cerament Bone Void FillerBonesupport AB · 2005 · cites it directly10descendants
- K073316Cerament Bone Void Filler, Model A0210Bonesupport AB · 2008 · 2 generations on6descendants
- K201535Cerament Bone Void FillerBonesupport AB · 2020 · 3 generations on3descendants
- K212083Tactoset Injectable Bone SubstituteAnika Therapeutics, Inc. · 2021 · 4 generations on2descendants
- K071004Osteocrete Bone Void FillerBone Solutions, Inc. · 2009 · 2 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K022622 | Cem-Ostetic, Models Cemo-020O, Cemo-05P, Cemo-10P, Cemo-20P, and Cemo-30P | Berkeley Advanced Biomaterials, Inc. | 2003 | — |
| +1 | K051951 | Cerament Bone Void Filler | Bonesupport AB | 2005 | — |
| +2 | K073316 | Cerament Bone Void Filler, Model A0210 | Bonesupport AB | 2008 | — |
| +3 | K201535 | Cerament Bone Void Filler | Bonesupport AB | 2020 | — |
| +4 | K212083 | Tactoset Injectable Bone Substitute | Anika Therapeutics, Inc. | 2021 | — |
| +2 | K071004 | Osteocrete Bone Void Filler | Bone Solutions, Inc. | 2009 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 2 | 0 |
| 2005 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2013 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQV device
- #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | OsteoSet BTF Kit Named without a submission number | |
| * | — | Osteoplast Named without a submission number |
What descends from it? (13)
See all 133 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K051951 (Bonesupport AB, 2005) has gone furthest, with 10 descendants of its own.
How does its category compare?
All MQV devicesMQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MQV
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MQV
57in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQV
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQV
57in 2025
MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 144 | 5 | 67 |
| 2008 | 32 | 102 | 3 | 71 |
| 2009 | 23 | 180 | 1 | 81 |
| 2010 | 17 | 147 | 0 | 68 |
| 2011 | 16 | 92 | 6 | 114 |
| 2012 | 9 | 107 | 3 | 149 |
| 2013 | 12 | 197 | 2 | 223 |
| 2014 | 20 | 153 | 0 | 111 |
| 2015 | 18 | 184 | 0 | 125 |
| 2016 | 8 | 214 | 1 | 106 |
| 2017 | 17 | 124 | 1 | 107 |
| 2018 | 23 | 124 | 2 | 86 |
| 2019 | 13 | 90 | 0 | 65 |
| 2020 | 15 | 132 | 1 | 126 |
| 2021 | 8 | 88 | 0 | 101 |
| 2022 | 9 | 118 | 0 | 47 |
| 2023 | 21 | 74 | 3 | 120 |
| 2024 | 28 | 55 | 2 | 68 |
| 2025 | 14 | 57 | 1 | 57 |
| 2026 | 5 | 96 | 4 | — |
What is it indicated for?
Cem-OsteticTM is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The Cem-OsteticTM paste set in situ or ex situ provides a void filler that can augment hardware to…
Read the full statement (126 words)
Cem-OsteticTM is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium.
The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The Cem-OsteticTM paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. Cem-OsteticTM is biocompatible and resorbs in the body as bone ingrowth occurs.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K022622 · printed Nov 6, 2026
Cite this page
510(k) Report. “K022622: Cem-Ostetic, Models Cemo-020O, Cemo-05P, Cemo-10P, Cemo-20P, and Cemo-30P.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K022622
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026