510(k) Report

510(k) · Cleared

Cleared

Lifejet F16 Hemodialysis/Apheresis Chronic Catheter

K022905510(k) TraditionalCleared Dec 13, 2002101-day reviewClass II21 CFR 876.5540

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Horizon Medical Products, Inc. · MSD Catheter, Hemodialysis, Implanted

Cleared on Dec 13, 2002 as substantially equivalent to K011916 (Horizon Medical Products, Inc., 2001) after a 101-day review. Its family tree reaches back 2 generations to 1994.

Decided
Dec 13, 2002
Review
101 days
Class
Class II
Product code
MSD
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K925819 (1994). 5 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2001: 1 other ancestor1998: 2 other ancestorsK925819 · AKCESS0CATH Kit · Akcess Medical Products, Inc. · 1994K011916 · Super C Hemodialysis/Apheresis Chronic Catheter, Model DC-36 Series, DC-40 Series, DC-45 Series · Horizon Medical Products, Inc. · 200119901992199419961998200020022004
  1. Root · 2 generations backK925819 AKCESS0CATH KitAkcess Medical Products, Inc. · 1994
  2. 1 generation backK011916 Super C Hemodialysis/Apheresis Chronic Catheter, Model DC-36 Series…Horizon Medical Products, Inc. · 2001
  3. This deviceK022905 Lifejet F16 Hemodialysis/Apheresis Chronic CatheterHorizon Medical Products, Inc. · 2002
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K925819AKCESS0CATH KitAkcess Medical Products, Inc.1994—
−1K011916Super C Hemodialysis/Apheresis Chronic Catheter, Model DC-36 Series, DC-40…Horizon Medical Products, Inc.2001—
0 (this device)K022905Lifejet F16 Hemodialysis/Apheresis Chronic CatheterHorizon Medical Products, Inc.2002—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199820
200110
FIG. 1 — Lineage of K022905, 1994–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MSD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MSD device

  1. #1 K241581 Hemodialysis Catheterscore 12.3 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K011916Super C Hemodialysis/Apheresis Chronic Catheter, Model DC-36 Series, DC-40 Series, DC-45…Horizon Medical Products, Inc.2001—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 2 companies; a new generation was cleared every 7.2 years on median.
  • None of the 5 ancestors has a recall.

How does its category compare?

All MSD devices

MSD Catheter, Hemodialysis, Implanted: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MSD

1in 2025

2007: 72008: 32009: 62010: 42011: 72012: 22013: 52014: 82015: 12016: 22017: 22018: 22019: 12020: 42021: 42025: 1
2007high 8 (2014) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MSD

153in 2021

2007: 92 days median2008: 89 days median2009: 81 days median2010: 116 days median2011: 70 days median2013: 105 days median2014: 246 days median2020: 106 days median2021: 153 days median
2007high 246 (2014) · low 70 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MSD

1in 2013

2008: 472009: 492010: 112011: 242013: 12026 (partial year): 4, 4 Class I
2007high 49 (2009) · low 0 (2007)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · MSD

1,054in 2025

2007: 1182008: 1742009: 1732010: 3062011: 2682012: 3672013: 3632014: 5062015: 5502016: 5322017: 4842018: 4632019: 6452020: 4012021: 5232022: 6102023: 5422024: 8412025: 1,054
2007high 1,054 (2025) · low 118 (2007)2025

MAUDE reports naming product code MSD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077920118
200838947174
200968149173
2010411611306
201177024268
20122—0367
201351051363
201482460506
20151—0550
20162—0532
20172—0484
20182—0463
20191—0645
202041060401
202141530523
20220—0610
20230—0542
20240—0841
20251—01,054
20260—4 (4)—

What is it indicated for?

The LifeJetTMF16 Hemodialysis/Apheresis Chronic Catheter is indicated for use in attaining short and long term vascular access for hemodialysis, hemoperfusion or apheresis therapy via the jugular or subclavian vein. The CatheteF is intended for implantation dwell time of greater than 30 days.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K022905: Lifejet F16 Hemodialysis/Apheresis Chronic Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K022905

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026